Electrical permit history — 2333 S Craycroft Rd

2333 S Craycroft Rd, Tucson — with 27 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

2333 S Craycroft Rd

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Build year not published — permits on file from 2004 · HVAC 2024 (finaled)

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2010 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. No permitted service or distribution work shows in the record we read. Gear of this era is generally still supported, but spare capacity drifts with every tenant improvement — worth a load check against the panel schedule before adding major equipment. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalFinaled permit foundLast permitted 2024 (2 years ago). Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. TC-UTL-0724-00038 — T924 - AT&T equipment swap on an existing 60' Monopalm. THIS PROJECT WILL BE COMPRISED OF: CHANGES ON THE EXISTING MONOPALM: · MOUNT SWAP TO VFA8-HD · REMOVE (6) EXISTING ANTENNAS. · REMOVE ALL EXISTING NOKIA RADIOS. · INSTALL (2) NEW WCS-IMFQ-AMT FILTERS ON P1 BC · REMOVE (2) EXISTING KFTDR00110030 FILTERS ON P1 BC · INSTALL NEW 840-370966KANTENNA ON P1 ABC · INSTALL NEW AIR6419 B77D+AIR6419 B77G STACKED ANTENNA ON P2 ABC · INSTALL NEW 840-370799K ANTENNA ON P3 ABC · INSTALL NEW 4490 B5/B12 RADIO ON P1 ABC · INSTALL NEW 4415 B30 RADIO ON P1 ABC · INSTALL NEW 4478 B14 RADIO ON P3 ABC · INSTALL NEW 4890 B25/B66 RADIO ON P3 ABC · REUSE EXISTING DC AND FIBER TRUNKS · REINSTALL ALL PALM FRONDS CHANGES IN THE EXISTING AT&T EQUIPMENT ENCLOSURE AREA: · REMOVE ALL (E) NOKIA BBUS · INSTALL (1) SAU, (1) XMU, (2) 6651 & (1) 6610 IN EXISTING RACK AC/DC SCOPE: DC POWER PLAN REVIEW: · INSTALL BREAKERS FOR E// BBUS · INSTALL (1) NEW -58V EXTERNAL STANDALONE CONVERTER SYSTEM -58V · INSTALL (10) NEW -58V CONVERTERS · INSTALL NEXTGEN SMART CONTROLLER · INSTALL (6) -48V RECTIFIERS · INSTALL (3) 50 AMP BREAKERS FOR 4490 B5/B12 RADIOS · INSTALL (3) 25 AMP BREAKERS FOR 4415 B30 RADIOS · INSTALL (3) 50 AMP BREAKERS FOR AIR6419 B77D RADIOS · INSTALL (3) 50 AMP BREAKERS FOR AIR6419 B77G RADIOS · INSTALL (3) 50 AMP BREAKERS FOR 4890 B25/B66 RADIOS · INSTALL (3) 25 AMP BREAKERS FOR 4478 B14 RADIOS BATTERY CHECK: · RETAIN (20) EXISTING POWER SAFE 170 BATTERIES (5) STRINGS TOTAL · INSTALL (8) NEW POWER SAFE 190 (2) STRINGS A/C PANEL REVIEW: · SEE PANEL SCHEDULE HVAC UNITS: · NO WORK - OUTDOOR EQUIPMENT
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2013. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Routine

    A trade permit was pulled in 2021. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “I-10 and Valencia Rd”, is about 2.3 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
131060210
Year constructed
2004 (earliest permit on file)
Permitting authority
Tucson
Zoning
C-2
Property type
Misc Commercial

The most recent permitted work on this parcel was in 2024. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2024. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 27 building permits for this parcel dated between 2004 and 2024. By category the work is trade permit (10), permanent sign (8), addition / alteration (5) and cell tower building. 20 of them carry a final inspection; the other 7 were issued, expired or are still open, which is not the same as work completed. There are 5 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 131060210. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All commercial property · Commercial property in 85711 · Commercial & industrial reports · Homes in 85711 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on S CRAYCROFT RD hold 1,299 City permits on record, 292 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (32 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2024TC-UTL-0724-00038Cell Tower Building PermitInspections Complete
2022CE-VIO1122-00273Code enforcement caseClosed - Unfounded
2022T22CM04980Commercial Trade PermitIssued
2021T20CM09194Commercial Trade PermitComplete
2018T18CM04001Commercial Addition/Alteration PermitCanceled
2016T16CM05947Commercial Trade PermitComplete
2016T16SE00081Mayor Council Special ExceptionApproved
2015T15DV05800SIGN VIOLATIONCOMPLIAN
2013T13OT00635Permanent Sign PermitComplete
2013T13CM03100Commercial Trade PermitComplete
2013T12CM07524Commercial Trade PermitComplete
2011T11DV09602SIGN VIOLATIONCOMPLIAN
2011T11OT00106Permanent Sign PermitCanceled
2010T10OT02609Commercial Addition/Alteration PermitComplete
2010T10SE00124Zoning Examiner Special ExceptionCanceled
2010T10PRE0066Pre-Application ConferenceCanceled
2010T10EL01590Commercial Trade PermitComplete
2010T10DV01947MULTIPLE TYPESCOMPLIAN
2010T10OT00097Commercial Addition/Alteration PermitComplete
2010T08OT02030Commercial Addition/Alteration PermitComplete
2008T08EL01743Commercial Trade PermitComplete
2008T08OT00917Permanent Sign PermitComplete
2008T08DV02365SIGN VIOLATIONCOMPLIAN
2007T07DV10329Permanent Sign PermitComplete
2004T04OT02360Permanent Sign PermitComplete
2004T04OT02326Commercial Addition/Alteration PermitWithdrawn
2004T04OT01822Permanent Sign PermitComplete
2004T04OT01508Permanent Sign PermitComplete
2004T04PL01221Commercial Trade PermitComplete
2004T04EL01393Commercial Trade PermitComplete
2004T04CM02371Commercial Trade PermitComplete
2004T04OT01271Permanent Sign PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 131060210 — 27 City permits on file from 2004 to 2024 and 5 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The assessor’s building record, the sewer connection file and the flood map were also not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.