Electrical permit history — 4815 E 29th St
4815 E 29th St, Tucson — built 1981, with 15 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
4815 E 29th St
Built 1981 — 1980s commercial stock · 15 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 4815 E 29th St (aztucsonelectricalsolutions.com/property/131044010/4815-e-29th-st-tucson-az-85711) · Public records last checked 2026-08-16
- Parcel
- 131044010
- Built
- 1981 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-2
- Assessor use
- Multiuse Or Miscellaneous Industrial
- Parcel size
- 0.61 acres
- Building area
- 10,500 sq ft (assessor record)
- Sewer
- Connection on file (1980) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2004 spklr permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2004 spklr permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyLikely dueLast permitted 2004 (22 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T04BU02122 — SPRINKLERS:RELOCATE
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
Industrial and warehouse space usually means three-phase motor loads. High-bay LED retrofits and added VFDs both change the load picture.
Recorded sales (1)
| Date | Price | Type |
|---|---|---|
| 1999-11-24 | $380,000 | Special Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2022-04-08 (T22CM02580) — Add or replace antennas, ancillary equipment and ground equipment as per plans for an existing carri.
Permit history (15)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2022-04-08expired 2023-08-07 | T22CM02580City permit record | Commercial BuildingAdd or replace antennas, ancillary equipment and ground equipment as per plans for an existing carri | Issued | |
| 2021-12-13finaled | T21RW05245City permit record | ROWTEP WILL BE REMOVING 1 POLE IN THE ROW IN A 2' X 2' HOLE 6' DEEP WILL BE BACKFILLED WITH OUT SIDEWALK IMPACT PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF PRECONSTRUCTION MEETING 1. BUS STOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-206-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 24-HOURS PRIOR TO START OF WORK FOR COORDINATION. 2. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. 3. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. 4. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. 5. MAINTAIN PEDESTRIAN ACCESS 6. IN THE EVENT THAT WEEKEND OR AFTER-HOURS WORK IS INTENDED, CONTACT COT INSPECTION STAFF. IF WEEKEND WORK, MAKE CONTACT 48 HOURS PRIOR TO THE WEEKEND. DAN ROBERTSON- 520-400-6722 OR TOM ADKINS- 520-400-3813 | Final | |
| 2017-06-02expired 2018-12-08 | T17CM04354City permit record | COMBOCELL TOWER/ VERIZON | Expired | |
| 2015-08-25finaled | T15CM05932City permit record | COMBOREPL ANTENNA | Final | |
| 2015-08-21 | T15CM05859City permit record | COMBOANTENNA SWAP | Withdrwn | |
| 2014-05-02expired 2014-09-02 | T14EX00483City permit record | EXCAVNEW RISER ON POLE # 199; BORE 5' WEST TO NEW HH ON NORTHSIDE OF E. 29TH ST. JOB # 095B RENEWED 07/02/2014-IMEDINA | Closed | |
| 2013-08-20finaled | T13CM05129City permit record | COMBOANTENNA SWAP FOR CELL TOWER | Final | |
| 2011-07-15finaled | T11CM02258City permit record | COMBOCELL TOWER MODIFICATION | Final |
Show 7 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2011-07-15finaled | T11OT01402City permit record | FLOODPLNFLOODPLAIN USE PERMIT CELL TOWER MODIFICATION | Final | |
| 2009-11-25expired 2011-02-13 | T09CM03103City permit record | Addition / alterationCELL ANTENNAS (ADDITION TO EXISTING) | Expired | |
| 2009-11-25 | T09OT02541City permit record | FLOODPLNFLOODPLAIN USE PERMIT: ANTENNAS | Issued | |
| 2009-09-17completed 2009-10-22 | T09SE00031Special exception | Zoning Examiner Special ExceptionSE-09-31 Clearwire-29th Street - A request for approval to allow the collocation of a new Wireless Network to an existing 53 foot high monopole and associated ground equipment.SE-09-31 Clearwire-29th Street | Approved | |
| 2004-08-27finaled | T04BU02122City permit record | SPKLRSPRINKLERS:RELOCATE | Final | |
| 2004-08-05finaled | T04BU01942City permit record | SPKLRFIRE SPKR:ADD 11 | Final | |
| 1998-05-08finaled | T98BU01157City permit record | SPKLRFIRE SPKR:ADD 4 | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (4)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2018-06-29 | T18DV03793Code enforcement case | Refuse | Noverify |
| 2013-11-19 | T13DV08600Code enforcement case | Vegetation | Noverify |
| 2009-04-01 | T09DV01630Code enforcement case | Vegetation | Complian |
| 2007-08-10finaled | T07FR01550Code enforcement case | Code enforcement case | Complete |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, once. No list, no follow-up unless you ask for it.
How this report was built
This is a reading of public records for parcel 131044010 — 15 permits on file from 1998 to 2022 (5 combo, 3 spklr, 2 floodpln, 1 commercial building) and 4 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.