Electrical permit history — 1923 S Country Club Rd

1923 S Country Club Rd, Tucson — built 1998, with 19 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

1923 S Country Club Rd

Built 1998 — 1990s commercial stock · 19 permits on record; no permitted panel/service or HVAC work among them

Parcel
13011001D
Built
1998 (county record)
Jurisdiction
Tucson
Zoning
C-3
Assessor use
Radio Tv Cable Tv Antenna Tv Systems
Parcel size
0.06 acres
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 1923 S Country Club Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2022-12-07 (TC-UTL-1222-00024) — ATC 82312 - Verizon equipment upgrade on an existing commercial cell tower. No change to tower height or compound size..

Permit history (19)

Permit history for this parcel — 8 of 19 records
DateRecordWhatStatusValue
2022-12-07expired 2023-11-01TC-UTL-1222-00024City permit recordUtilitiesATC 82312 - Verizon equipment upgrade on an existing commercial cell tower. No change to tower height or compound size.Issued
2022-11-18TC-COM-1122-00142City permit recordCommercial BuildingVoid-VF-Wrong permit category type. Please resubmit under Cell Tower Building Permit. Cell Tower Form needs to be filled out completely for review. Antenna modifications on existing cell tower. See construction drawings for more info.Void
2015-10-29finaledT15CM07548City permit recordCOMBOCELL TOWERFinal
2015-05-04expired 2015-07-06T15EX00741City permit recordEXCAVNEW RISER ON POLE # 138, TRENCH 5' TO NEW HH THEN TRENCH NE 85' TO NEW HH ON THE EAST SIDE OF SOUTH COUNTRY CLUB RD. JOB SEG # 087A UG (REFER TO T14EX00505)Expired
2015-04-30expired 2015-06-29T15EX00690City permit recordEXCAVNEW RISER ON POLE # 138, TRENCH 5' TO NEW HH THEN TRENCH NE 85' TO NEW HH ON THE EAST SIDE OF SOUTH COUNTRY CLUB RD. JOB. SEG # 087A UG REF # T14EX00505Closed
2014-05-06expired 2014-09-03T14EX00505City permit recordEXCAVNEW RISER ON POLE # 138, TRENCH 5' TO NEW HH THEN TRENCH N.E. 85' TO NEW HH ON THE EAST SIDE OF S. COUNTRY CLUB RD. JOB # SEG #087A UG RENEWED 07/03/2014-IMEDINAClosed
2014-05-06expired 2014-09-03T14EX00507City permit recordEXCAVPLACE ANCHOR ON POLE# 22 WEST JOB # SHEET # 001 RENEWED 07/03/2014-IMEDINAClosed
2014-05-06expired 2014-09-03T14EX00522City permit recordEXCAVA-PLACE ANCHOR ON POLE # 207 WEST B-PLACE ANCHOR ON POLE # 2 EAST JOB # 4 RENEWED 07/03/2014-IMEDINAClosed
Show 11 older records
Permit history for this parcel — remaining 11 records
DateRecordWhatStatusValue
2014-05-06expired 2014-09-03T14EX00523City permit recordEXCAVPLACE ANCHOR ON POLE # 271 SOUTH, PLACE ANCHOR ON POLE # 160 NORTH, PLACE ANCHOR ON POLE #138 SOUTH JOB # 5 RENEWED 07/03/2014-IMEDINAClosed
2013-11-01T13CM06678City permit recordCOMBOREPLACE ANTENNASExpired
2013-06-19expired 2014-08-20T13CM03715City permit recordCOMBOINSTALLATION OF NEW LESSEE ANTENNASExpired
2011-04-18expired 2011-12-11T11CM01122City permit recordCOMBOINSTALL:NEW MICROWAVE DISH- ADD 2 MICROWAVE DISHES ON EXISTING ANTENNA TOWERExpired
2011-03-02expired 2011-05-01T11EX00081City permit recordEXCAVEXCAV: 550' OF TRENCH& CUT & REMOVE 22' OF SIDEWALClosed
2011-02-25expired 2011-04-26T11EX00076City permit recordEXCAVDIG AND PLACE CONDUIT FOR TW TELCOM FORM POLE AT S/W CORNER OF PROPERTY AND GO NORTH FOR 135' . WORK DONE ON PROPERTY SIDE OF SIDEWALK. CUT & REMOVE 22' OF DRIVEWAY AND REPLACE.Closed
2010-04-14finaledT10CM01006City permit recordCOMBOREPL ANTENNAS IN CELL TOWERFinal
2010-01-22expired 2011-02-19T10CM00185City permit recordCOMBOATTACH ANTENNAS TO EXISTING MONOPOLE, INSTALL EQUIPMENT CABINET ON A METAL PLATFORMExpired
2009-10-28completed 2009-11-17T09SE00044Special exceptionZoning Examiner Special ExceptionSE-09-44 - Clearwire, C.C. Rd. - The applicant is requesting a Special Exception to allow the co-location of a wireless facility on an existing 74-foot-high monopole with associated ground equipment on a 0.57-acre site.SE-09-44 - Clearwire, C.C. Rd.Approved
2007-10-19expired 2008-09-15T07CM04130City permit recordCOMBOREPLACE:ANTENNAE & INSTALL:GENERATORClosed
2000-10-13finaledT00CM05105City permit recordCOMBOROOFTOP CELLULAR INSTALLATIONFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (3)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 3 of 3 records
DateRecordWhatStatus
2024-01-24CE-VIO0124-00346Code enforcement caseVegetationClosed - unfounded
2023-07-17CE-VIO0723-04571Code enforcement caseCode enforcement caseClosed - unfounded
2011-05-17T11DV03608Code enforcement caseVegetationComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 13011001D — 19 permits on file from 2000 to 2022 (8 combo, 8 excav, 1 utilities, 1 commercial building) and 3 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.