Electrical permit history — 1310 S Alvernon Wy

1310 S Alvernon Wy, Tucson — built 1970, with 26 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

1310 S Alvernon Wy

Built 1970 — 1970s commercial stock · HVAC 2013 (permit expired without a confirmed final)

Parcel
130070050
Built
1970 (county record)
Jurisdiction
Tucson
Zoning
C-3
Assessor use
Restaurant Sit Down
Parcel size
0.44 acres
Sewer
Connection on file (1969) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 1310 S Alvernon Wy, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2023 fire construction permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalPermitted — completion not confirmedA 2013 permit specifies this work (the permit description states “REPLACE 3 TON ROOFMOUNT HEAT PUMP”), but the available record does not show a final inspection. The permit expired without a confirmed final status. Official status: Expired. T13CM00579 — REPLACE 3 TON ROOFMOUNT HEAT PUMP
  • Fire alarm & life safetyCurrentLast permitted 2023 (3 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0723-00844 — New Fire Suppression System Install for Kitchen Hood
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Food service carries heavy, cycling kitchen loads and exhaust interlocks. Capacity and existing panel space are the first things to verify on any remodel.

  • Worth confirming

    There is an electrical reconnect permit from 2016. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

Most recent permit on record for this parcel: 2025-04-02 (TC-COM-0425-00652) — Electric Vehicle charging equipment installation..

Permit history (26)

Permit history for this parcel — 8 of 26 records
DateRecordWhatStatusValue
2025-04-02finaledTC-COM-0425-00652City permit recordCommercial BuildingElectric Vehicle charging equipment installation.Complete
2023-07-07finaledTF-FCP-0723-00844City permit recordFire ConstructionNew Fire Suppression System Install for Kitchen HoodComplete
2018-04-05finaledT18RW01530City permit recordROWREMOVAL OF AERIAL FIBER OPTIC PLEASE NOTIFY DES OF CLOSURE - SABRINA CORTEZ (520)872-9019 Pedestrian access must be provided and maintained per MUTCD Chapter 6D. Field adjustments may be required.Final
2016-10-19finaledT16CM07924City permit recordElectrical reconnectELECTRICAL RECONNECTFinal
2013-05-31finaledT13CM03317City permit recordCOMBORECONNECT ELECTRIC:COMMERICALFinal
2013-02-26finaledT13BU00215City permit recordBUILDBILLBOARD REPAIRFinal
2013-01-31expired 2013-07-30T13CM00579City permit recordCOMBOREPLACE 3 TON ROOFMOUNT HEAT PUMPExpired
2012-05-18T12CM02839City permit recordCOMBOINCLOSED PATIOWithdrwn
Show 18 older records
Permit history for this parcel — remaining 18 records
DateRecordWhatStatusValue
2012-03-12finaledT12CM01013City permit recordCOMBOREPLACE AWNING FOR BARFinal
2011-02-22finaledT11EL00486City permit recordELECTEMERGENCY REPAIR TO DAMAGED DISCONNECTFinal
2010-03-12finaledT10EL00564City permit recordELECTLIGHTING MODIFICATION FOR BILLBOARDSFinal
2010-02-01finaledT10EL00204City permit recordELECTBILLBORARD:AUTHORIZED REPAIRFinal
2010-01-27finaledT10OT00199City permit recordSIGN17838Final
2010-01-26T10BU00150City permit recordBUILDBILLBOARD:AUTHORIZED REPAIRVoid
2008-04-10finaledT08CM01144City permit recordCOMBOINSTALLING NEW BLOWER AND M.U.A SYSTEMFinal
2007-12-17expired 2008-06-30T07BU02604City permit recordBUILDKITCHEN HOOD SYSTEMExpired
2007-11-13finaledT07OT02558City permit recordSIGN14006Final
2006-04-13finaledT06OT01005City permit recordSIGN11001Final
2005-10-13finaledT05OT02544City permit recordSIGNSIGN:#9876Final
2002-10-31finaledT02OT01730City permit recordSIGNSIGN:4699Final
2002-08-14finaledT02OT01249City permit recordSIGNSIGN:4345Final
2002-01-16finaledT02OT00081City permit recordSIGNSIGN:3546Final
2001-11-19finaledT01OT00929City permit recordSIGNSIGN:3313Final
2001-08-09finaledT01OT00299City permit recordSIGNSIGN:2884Final
2000-11-03finaledT00OT00298City permit recordC-OF-OC OF O:BAR & GRILLC of o
1997-12-24finaledT97EL02174City permit recordELECTREPAIR:ELECTRICFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (15)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 15 records
DateRecordWhatStatus
2023-04-18CE-VIO0423-02998Code enforcement caseVegetationClosed - unfounded
2021-12-04T21DV08576Code enforcement caseVegetationNoverify
2020-09-28T20DV06495Code enforcement caseVegetationReferred
2020-08-17T20DV05677Code enforcement caseVegetationComplian
2019-07-16T19DV05706Code enforcement caseElectricalComplian
2015-11-02T15DV08442Code enforcement caseVegetationNoverify
2014-05-29T14DV03463Code enforcement caseCode enforcement caseComplian
2013-08-02T13DV05638Code enforcement caseGraffitiNoverify
Show 7 older records
Code enforcement history for this parcel — remaining 7 records
DateRecordWhatStatus
2012-03-15T12DV02068Code enforcement caseCode enforcement caseCourtcmp
2011-08-03T11DV06220Code enforcement caseWork without permitNoverify
2009-11-16finaledT09FR03565Code enforcement caseCode enforcement caseComplete
2009-07-09T09DV03911Code enforcement caseSignComplian
2008-12-10T08DV11265Code enforcement caseZoningComplian
2007-11-14T07DV12191Code enforcement caseSignComplian
2006-05-04finaledT06FR01194Code enforcement caseCode enforcement caseComplete

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 130070050 — 26 permits on file from 1997 to 2025 (9 sign, 5 combo, 4 elect, 3 build) and 15 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.