Electrical permit history — 3051 E 36th St

3051 E 36th St, Tucson — built 1964, with 29 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

3051 E 36th St

Built 1964 — 1960s commercial stock · 29 permits on record; no permitted panel/service or HVAC work among them

Parcel
130056900
Built
1964 (county record)
Jurisdiction
Tucson
Zoning
C-1
Assessor use
Store & Office Or Store & Apt Combo
Parcel size
0.53 acres
Building area
5,264 sq ft (assessor record)
Sewer
Connection on file (1964, 2017, 2025) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 3051 E 36th St, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2017 (9 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T17FC00456 — New Install of Hood Suppression system
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2022. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Routine

    Office and medical tenant improvements are usually limited by available panel spaces and branch circuit capacity, not by the service itself.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2023-02-09$600,000Warranty Deed
2007-01-19$320,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-05-01 (TZ-PMT-0526-00037) — Sonoran hotdogs, fast food and drinks.

Permit history (29)

Permit history for this parcel — 8 of 29 records
DateRecordWhatStatusValue
2026-05-01TZ-PMT-0526-00037City permit recordZoning Permit AnnualSonoran hotdogs, fast food and drinksNeeds resubmittal
2024-06-26TZ-PMT-0624-00043City permit recordZoning Permit AnnualEl Perro Loco Hot DogsExpired
2023-12-11finaledTR-UTL-1223-03029City permit recordRight-of-Way (ROW) - UtilityWO 6262334 - Working within ROW to replace poles. Trench along shoulder to re-feed existing UG Primary. Continuation of permit TR-UTL-0523-01605.Complete
2023-10-31expired 2024-05-26TC-RES-1023-09184City permit recordResidential Building - One or Two FamilyResidential house 55 feet gas pipe redone because of SWG company said that under the ground pipeline has leek somewhere. After redone the pipeline City of Tucson need to be inspected before reconnecting the gas.Issued
2023-09-20expired 2026-03-09TC-COM-0923-02245City permit recordCommercial BuildingCODE VIOLATION, BUILT W/O PERMIT. REPLCED TO ROOF MOUNT AC. ADDED WALK COOLER AND RELOCATED SALES COUNTERIssued
2023-05-20finaledTR-UTL-0523-01605City permit recordRight-of-Way (ROW) - UtilityWO 6262334 & WO T48500 - Replace (5) Poles, Remove (3) Poles. Install (1) Anchor. Install Approx. 1065' OH Wire. Trench & Install 140' of conduit & cable and 1 junction cabinet on NE Corner of Fairland Stravenue & Country Club. Overhead Work (5) Locations along Country Club from Rickey Vista to Fairland Stravenue. Install (1) Pole & (1) Overhead Work Location at Country Club & Aviation Highway (AZ-210). Previous permits expired T21RW03882 and T22RW00449Complete
2023-01-13expired 2024-01-19TZ-PMT-0123-00025City permit recordZoning Permit AnnualMobile Food Truck (fast food/ hot dogs) parked on Henry's Market parking lot to sale food.Expired
2022-02-09finaledT22RW00449City permit recordPool / spaReplace (6) Poles, and Install (1) Pole. As well as 5 Locations with Overhead Work along Country Club from 36th to Fairland Stra. Install Approx. 1065' OH Wire in COT ROW. Install (1) Pole & (1) Overhead Work Location at Country Club & Aviation Highway (AZ-210) Trench 20' on NW Corner of Fairland Stravenue & Country Club to Transfer UG to New Pole. Original permit T21RW03882 has expired.; Work Order: 6262334 PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRATIVE MANUAL. UNDER A PAVEMENT MORATORIUM, ANY NEW ASPHALT THAT IS DISTURBED WILL REQUIRE A 2” MILL AND OVERLAY FOR 50’ IN EACH DIRECTION FROM THE OUTSIDE OF THE CUT FOR ALL EFFECTED TRAVEL LANES. 1. BUS STOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-206-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 24-HOURS PRIOR TO START OF WORK FOR COORDINATION. 2. PLACE "BUSINESS ACCESS" SIGNS APPROPRIATELY. SEVERAL BUSINESSES ALONG ROUTE. 3. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. 4. ALL AERIAL WORK MUST BE A MINIMUM OF 16-FT HIGH. AND MUST BE A MINIMUM OF 18-FT HIGH WHEN CROSSING INTERSECTIONS, PAVEMENT AND ALLEYS. 5. PAVEMENT PATCHING IS NECESSARY WHERE PAVEMENT IS CUT. PATCH LIMITS- THE LIMITS OF THE PAVING SHALL BE A MINIMUM OF 1-FT OUTSIDE THE EXCAVATION. 6. POTHOLES SPACED CLOSELY TOGETHER AND WITHIN 8-FT OF EACH OTHER WILL NEED TO BE JOINED TOGETHER BY ONE SURFACE PATCH. 7. BACKFILL WITH CLSM SLURRY OR AGGREGATE BASE COURSE (ABC.) 8. ASPHALTIC CONCRETE USED SHALL BE CITY OF TUCSON MIX NO. 3 OR COT MIX NO. 2 WITH TR-22, INSPECTOR TO ADVISE. 9. REPLACE/ REFRESH ALL STRIPING THAT IS INTERRUPTED BY PATCHES. 10. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. 11. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. 12. MAINTAIN PEDESTRIAN ACCESS 13. MAINTAIN ACCESS TO BUS STOPS AND FOR PEDESTRIAN INGRESS/ EGRESS. 14. IN THE EVENT THAT WEEKEND OR AFTER-HOURS WORK IS INTENDED, CONTACT COT INSPECTION STAFF. IF WEEKEND WORK, MAKE CONTACT 48 HOURS PRIOR TO THE WEEKEND. DAN ROBERTSON- 520-400-6722 OR TOM ADKINS- 520-400-3813 09/03/2022 - PLAN CHANGE R4 Replace (5) Poles, Remove (3) Poles. Install (1) Anchor. Install Approx. 1065' OH Wire. Trench & Install 140' of conduit & cable and 1 junction cabinet on NE Corner of Fairland Stravenue & Country Club. Overhead Work (5) Locations along Country Club from Rickey Vista to Fairland Stravenue. Install (1) Pole & (1) Overhead Work Location at Country Club & Aviation Highway (AZ-210).Complete
Show 21 older records
Permit history for this parcel — remaining 21 records
DateRecordWhatStatusValue
2020-04-27expired 2021-04-27T20OT00340City permit recordPEDDLERREGULATED PEDDLER: EL PERRO LOCO HOTDOGS LLC, PC HEALTH DEPT LIC 3140072 - EXP 1/31/2021, SITE PLAN APPROVEDExpired
2020-04-17finaledT20RW02238City permit recordROW20R0962 - REPAIR LEAKING MAIN AT THE NORTH WEST SHOULDER OF THE INTERSECTION OF S COUNTRY CLUB RD AND E 36TH ST. EMERGENCY - AFTER THE FACT PERMITFinal
2019-03-28expired 2020-03-28T19OT00291City permit recordPEDDLERREGULATED PEDDLERExpired
2018-04-02expired 2019-04-02T18OT00348City permit recordPEDDLERREGULATED PEDDLERExpired
2017-06-01finaledT17FC00456City permit recordFIRECONSNew Install of Hood Suppression systemFinal
2017-05-24finaledT17EL00152City permit recordELECTupgrade to 200 amps (VH)Final
2017-04-03expired 2018-04-03T17OT00359City permit recordPEDDLERPeddler: El Perro Loco Hot Dogs/David Durand and Blanca Durand No extended hoursExpired
2017-02-16expired 2018-01-14T17CM01298City permit recordCOMBOREPL HOODExpired
2016-04-01expired 2017-04-01T16OT00407City permit recordPEDDLERRegulated Peddler: El Perro Loco Hot DogsExpired
2015-04-02expired 2016-04-01T15OT00444City permit recordPEDDLERPEDDLER: EL PERRO LOCO / DAVID DURANExpired
2014-05-13expired 2014-07-12T14EX00584City permit recordEXCAVTRENCHING 85' TO INSTALL PVC CONDUIT FOR TRANSIENT MONITORING SYSTEM. TRENCH WILL BE 3' DEEP X 1' DEEP WIDE. DRILLING 2" HOLE INSIDE OF CONCRETE VAULTS FOR TUCSON WATER MANHOLES - OFF S. COUNTY CLUB RD.Closed
2014-04-08expired 2015-04-08T14OT00421City permit recordPEDDLEREL PERRO LOCOExpired
2013-03-21expired 2014-03-21T13OT00353City permit recordPEDDLERPEDDLER: EL PERRO LOCO / DAVID DURAND GARCIA SITE OKAY FOR EXTENDED HOURSExpired
2012-03-26expired 2013-03-26T12OT00480City permit recordPEDDLERRegulated Peddler/EL PERRO LOCO/HOT DOGS SONORAN STYLE, WATER, CHIPS, SODASExpired
2011-06-15finaledT11OT01181City permit recordC-OF-OC OF O; GROCERY STOREC of o
2011-03-25expired 2012-03-24T11OT00544City permit recordPEDDLEREL PERRO LOCO RENEWALExpired
2008-03-06expired 2009-03-06T08OT00533City permit recordPEDDLERPEDDLER: EL PERRO TACO / DAVID DURANDExpired
2007-03-26expired 2008-03-25T07OT00690City permit recordPEDDLEREL PERRO LOCO: DAVID DURAND - RENEWALExpired
2006-05-15finaledT06CM02877City permit recordCOMBOPATCH S. ELEVATION T06VL00613Final
2005-04-14expired 2006-04-14T05OT00886City permit recordPEDDLEREL PERRO LOCO / David Durand REGULATED PEDDLER - Hot DogsExpired
2002-06-20finaledT02PL01167City permit recordPLUMBINSTALL: 2 WATER HEATERS (APA)Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (17)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 17 records
DateRecordWhatStatus
2024-12-30CE-VIO1224-05144Code enforcement caseRefuseClosed - unfounded
2023-03-14CE-VIO0323-02371Code enforcement caseWork without permitClosed - resolved
2022-05-02T22DV02743Code enforcement caseCode enforcement caseNoverify
2021-02-12T21DV00790Code enforcement caseRefuseComplian
2020-01-02T20DV00006Housing code violationRES: MINIMUM HOUSINGrecorded before 2023COMPLIAN
2019-12-04T19DV09192Code enforcement caseRefuseComplian
2018-09-19T18DV05918Code enforcement caseRefuseComplian
2014-08-20T14DV06345Code enforcement caseCode enforcement caseComplian
Show 9 older records
Code enforcement history for this parcel — remaining 9 records
DateRecordWhatStatus
2012-03-27T12DV02397Code enforcement caseCode enforcement caseNoverify
2012-01-19T12DV00363Code enforcement caseCode enforcement caseComplian
2011-10-04T11DV07959Code enforcement caseCode enforcement caseNoverify
2009-06-08T09DV03200Code enforcement caseCode enforcement caseVoid
2007-12-05T07DV12797Code enforcement caseCode enforcement caseInvalid
2007-11-01T07DV11849Code enforcement caseCode enforcement caseComplian
2007-10-10T07DV10785Code enforcement caseCode enforcement caseComplian
2006-05-08T06VL00613Code enforcement caseCode enforcement caseComplian
2002-05-03T02VL00908Code enforcement caseSignComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 130056900 — 29 permits on file from 2002 to 2026 (13 peddler, 3 zoning permit annual, 2 right-of-way (row) - utility, 2 combo) and 17 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.