Electrical permit history — 2385 S Plumer Av

2385 S Plumer Av, Tucson — built 1951, with 23 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

2385 S Plumer Av

Built 1951 — 1950s commercial stock · HVAC 2009 (permit expired without a confirmed final)

Parcel
130054970
Built
1951 (county record)
Jurisdiction
Tucson
Zoning
R-2
Assessor use
Day Care/Pre-School Center Private
Parcel size
0.97 acres
Sewer
Connection on file (1964) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 2385 S Plumer Av, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalPermitted — completion not confirmedA 2009 permit specifies this work (the permit description states “REPLACE: HVAC SYSTEM LIKE FOR LIKE”), but the available record does not show a final inspection. The permit expired without a confirmed final status. Official status: Expired. Contractor of record: SOUTHERN COMFORT HEATING AND AIR CONDITIONING L. T09ME00157 — REPLACE: HVAC SYSTEM LIKE FOR LIKE
  • Fire alarm & life safetyLikely dueA newer 2017 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “Fire Alarm & Detection Systems - NEW ALARM SYSTEM; Fire Alarm Systems - New Sq Ft: 5344; Additional Plan Reviews: 1”. Last permitted 2005 (21 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T05BU01227 — FIRE SPKR: 20 NEW
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2026-07-21 (TF-FOP-0726-00977) — My Little Angels Daycare Center.

Permit history (23)

Permit history for this parcel — 8 of 23 records
DateRecordWhatStatusValue
2026-07-21finaledTF-FOP-0726-00977City permit recordFire OperationalMy Little Angels Daycare CenterComplete
2025-01-06TC-COM-0125-00042City permit recordCommercial Buildingbuilt a see through metal cage to prevent children's transportation van from being vandalized.Expired
2024-12-23TZ-CMP-1224-00185City permit recordZoning Verification Letter**VOID - INCORRECT PERMIT TYPE** Built a 10ft x 20ft see through free standing cage not connected to main building in any way or form. For children's school transportation Van to prevent vandalism of broken windows, stolen batteries, damaged gas tanks to steal fuel, prevent theft of catalytic converter , and tire damage.Void
2024-06-17finaledTF-FOP-0624-00715City permit recordFire OperationalLittle Angles Daycare SLF I4 143 childrenComplete
2024-06-13TF-FOP-0624-00702City permit recordFire OperationalVOID-Submit a Fire State Licensed Facility Permit - State Licensed Facility Operational Fire Permit - Child Care FacilityVoid
2023-07-27finaledTF-FCP-0723-00902City permit recordFire ConstructionAdding Starlink Cellular Dialer to an existing fire systemComplete
2023-05-17finaledTF-FOP-0523-01029City permit recordFire OperationalDaycare CenterComplete
2023-03-31TF-FOP-0323-00752City permit recordFire OperationalGENERAL OPERATIONAL PERMITVoid
Show 15 older records
Permit history for this parcel — remaining 15 records
DateRecordWhatStatusValue
2022-02-28finaledT22FO00192City permit recordFIREOPER143 PERSONSFinal
2021-01-21finaledT21FO00043City permit recordFIREOPERMY LITTLE ANGELS DAYCARE CNTERS INC 143 CHILDRENFinal
2020-02-03expired 2021-07-10T20FO00114City permit recordFIREOPERMY LITTLE ANGELS DAYCARE - OCC: 148Void
2019-07-29finaledT19FO00581City permit recordFIREOPERLittle Angels Day Care - Occ 79Final
2018-07-20finaledT18FO00588City permit recordFIREOPEROCC 120Final
2017-05-01expired 2018-01-21T17FC00349City permit recordAddition / alterationFire Alarm & Detection Systems - NEW ALARM SYSTEM; Fire Alarm Systems - New Sq Ft: 5344; Additional Plan Reviews: 1Expired
2016-12-12finaledT16FO00148City permit recordFIREOPERDaycare - 132 childrenFinal
2010-12-07expired 2011-06-08T10BU01804City permit recordBUILDINSTALL:KITCHEN HOOD SYSTEMExpired
2010-09-23finaledT10CM02656City permit recordCOMBOTI: CHILD CAREFinal
2009-04-22expired 2009-10-19T09ME00157City permit recordMECHREPLACE: HVAC SYSTEM LIKE FOR LIKEExpired
2009-02-24finaledT09BU00267City permit recordAddition / alterationADDITION: SHADE STRUCTURE (CANOPY)Final
2007-07-16finaledT07EL01307City permit recordELECTREPL DAMAGED SERV FEEDERSFinal
2005-06-08expired 2005-08-07T05EX00619City permit recordEXCAVEXCAV:25LF TRENCH FOR FIRE SERVICE D CC PClosed
2005-05-18finaledT05BU01227City permit recordSPKLRFIRE SPKR: 20 NEWFinal
2004-03-01finaledT04CM00971City permit recordCOMBOSITE:MODULAR CLASSROOMSFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (2)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 2 of 2 records
DateRecordWhatStatus
2024-03-28CE-VIO0324-01181Code enforcement caseWork without permitClosed - resolved
2006-07-05finaledT06FR02153Code enforcement caseCode enforcement caseComplete

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 130054970 — 23 permits on file from 2004 to 2026 (6 fireoper, 5 fire operational, 2 addition / alteration, 2 combo) and 2 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.