Electrical permit history — 2500 E 22nd St
2500 E 22nd St, Tucson — built 1985, with 29 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
2500 E 22nd St
Built 1985 — 1980s commercial stock · HVAC 2008 (finaled)
Permanent link: Electrical permit history for 2500 E 22nd St (aztucsonelectricalsolutions.com/property/130030150/2500-e-22nd-st-tucson-az-85713) · Public records last checked 2026-08-16
- Parcel
- 130030150
- Built
- 1985 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-1
- Assessor use
- Credit Union
- Parcel size
- 0.43 acres
- Sewer
- Connection on file (1976) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2019 solar pv permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalLikely dueLast permitted 2008 (18 years ago). City inspection record: MECHANICAL - FINAL approved 2008-11-06. Contractor of record: RUSSETT SERVICE CORPORATION, *C. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Equipment from before about 2010 generally runs R-22, which has not been produced since 2020 — repairs mean reclaimed refrigerant at a price that often exceeds replacing the unit. T08ME00610 — REPLACE: 12 1/2 TON HEAT PUMP (APA)
- Fire alarm & life safetyPermitted — completion not confirmedA 2020 permit specifies this work (the permit description states “Fire Alarm & Detection Systems - Replace existing fire panel with new panel and new communicator; Fire Alarm Systems - New Sq Ft: 2500; Additional Plan Reviews: 1”), but the available record does not show a final inspection. The permit expired without a confirmed final status. Official status: Expired. T20FC00443 — Fire Alarm & Detection Systems - Replace existing fire panel with new panel and new communicator; Fire Alarm Systems - New Sq Ft: 2500; Additional Plan Reviews: 1
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
Solar was permitted here in 2019. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.
Most recent permit on record for this parcel: 2026-08-14 (TC-UTL-0826-00156) — Submission for development review for exterior additions only, includes exterior facade system and a new trash enclosure..
Permit history (29)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-08-14 | TC-UTL-0826-00156City permit record | Addition / alterationSubmission for development review for exterior additions only, includes exterior facade system and a new trash enclosure. | In review | |
| 2026-08-12 | TD-DEV-0826-00222City permit record | Addition / alterationRestricted Records-Submission for development review for exterior additions only, includes exterior facade system and a new trash enclosure. | In review | |
| 2026-07-17 | TR-UTL-0726-01190City permit record | Right-of-Way (ROW) - UtilityPRJ319431-1: Cox to pull thru 85' of existing CATV fiber in ROW, then continue onto private property for system tie. | Fees paid | |
| 2026-07-01 | TC-COM-0726-01006City permit record | Addition / alterationSubmission for permit and development review for exterior additions only, includes exterior facade signage and a new trash enclosure. | Fees paid | |
| 2025-12-12expires 2027-07-15 | TC-COM-1225-02249City permit record | Commercial BuildingTenant improvement of an existing bank branch with interior updates; use remains the same. Includes minor renovations and a new trash enclosure on the property. | Inspections | |
| 2023-07-28finaled | TR-ROW-0723-01007City permit record | Right-of-Way (ROW)Annual palm tree trimming project. | Complete | |
| 2021-03-03finaled | T21CM01900City permit record | COMBORun gas line for new gas service and gas generator | Final | |
| 2021-01-21finaled | T21RW00324City permit record | ROW(2) 5x5 bellholes in dirt/blktop front------to repair/replace/pothole gas line | Final |
Show 21 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2020-08-13finaled | T20RW04618City permit record | ROWCOVID SLOW STREETS PLACEMENT OF TEMPORARY BARRICADES TO SLOW TRAFFIC ON VARIOUS ROADS WITHIN THE BARRIO CENTRO NEIGHBORHOD. TUCSON BL., CROSBY VISTA, BRISTOL AV., WARWICK VISTA, KESWICK CI. 09/24/2020 - PLAN CHANGE - CONSTRUCTION PHASE II INSTALLATION OF SPEED HUMPS AND TRAFFIC CIRCLES WITH APPROPRIATE SIGNAGE. | Final | |
| 2020-07-07expired 2021-08-27 | T20FC00443City permit record | Addition / alterationFire Alarm & Detection Systems - Replace existing fire panel with new panel and new communicator; Fire Alarm Systems - New Sq Ft: 2500; Additional Plan Reviews: 1 | Expired | |
| 2019-01-15finaled | T19OT00052City permit record | FLOODPLNFUP FOR T19CM00267 | Final | |
| 2019-01-14finaled | DP19-0007City permit record | Solar PVSITE/SOLAR CANOPY - TUCSON OLD PUEBLO CREDIT UNION | Complete | |
| 2019-01-14finaled | T19CM00267City permit record | COMBOPV SYSTEM ON PARKING CANOPY | Final | |
| 2016-01-26expired 2016-08-10 | T16OT00123City permit record | Fence / wallREPLACING NEW DF ON EXISTING BASE / 1- ILLUM WALL SIGN | Expired | |
| 2012-02-27expired 2012-08-25 | T12CM00699City permit record | COMBOUPGRADE LIGHTING, NEW & REPLACE FIXTURES | Expired | |
| 2010-10-14finaled | T10OT02235City permit record | SIGNEXISTING 45 DAY BANNER 9-10-10 TO 10-24-10 | Final | |
| 2009-06-12finaled | T09OT01202City permit record | SIGN16801 | Final | |
| 2009-03-25expired 2010-08-01 | T09OT00597City permit record | SIGN16459 | Expired | |
| 2009-02-26expired 2009-06-12 | T09OT00399City permit record | SIGN16351 | Closed | |
| 2008-12-11finaled | T08OT02905City permit record | SIGN16032 | Final | |
| 2008-10-06finaled | T08ME00610City permit record | MECHREPLACE: 12 1/2 TON HEAT PUMP (APA) | Final | |
| 2007-12-14expired 2008-02-12 | T07EX01277City permit record | EXCAVEXCA:30' IN ASPHALT & DIRT ON TUCSON BL:50' TRENCH | Closed | |
| 2007-05-17finaled | T07ME00345City permit record | MECHREPLACE:HEAT PUMP (APA) | Final | |
| 2007-05-07expired 2007-12-30 | T07CM01909City permit record | COMBOTI:BANK | Closed | |
| 2005-02-01finaled | T05OT00222City permit record | SIGNSIGN:8427 TUCSON OLD PUEBLO CREDIT UNION | Final | |
| 2005-01-10finaled | T05OT00039City permit record | SIGNSIGN:8304 TUCSON OLD PUEBLO CREDIT UNION | Final | |
| 2004-02-11expired 2004-04-11 | T04EX00132City permit record | EXCAVEXCAV:16 LF SIDEWALK | Closed | |
| 2003-05-06finaled | T03OT00790City permit record | SIGNSIGN:5463 | Final | |
| 2003-03-18finaled | T03CM01354City permit record | COMBOREPLACE:20 TON A/C UNIT | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, once. No list, no follow-up unless you ask for it.
How this report was built
This is a reading of public records for parcel 130030150 — 29 permits on file from 2003 to 2026 (8 sign, 5 combo, 4 addition / alteration, 2 row) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.