Electrical permit history — 3004 E 22nd St
3004 E 22nd St, Tucson — built 1966, with 20 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
3004 E 22nd St
Built 1966 — 1960s commercial stock · last permitted panel/service work 2023 (finaled)
Permanent link: Electrical permit history for 3004 E 22nd St (aztucsonelectricalsolutions.com/property/13002003b/3004-e-22nd-st-tucson-az-85713) · Public records last checked 2026-08-16
- Parcel
- 13002003B
- Built
- 1966 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-1
- Assessor use
- Retail Strip Center
- Parcel size
- 1.03 acres
- Building area
- 9,370 sq ft (assessor record)
- Sewer
- Connection on file (1950, 1951) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- City records show the 2023 permit was finalized; the permit description states “WO#2506770_3000 E 22nd st 14-14-20. Install new 1' service line on southwest center of property 6LF/EM”.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionCurrentLast permitted 2023 (3 years ago). City inspection record: TRSP - ROW - Final/Close-Out approved 2023-05-11. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. TR-UTL-0323-01160 — WO#2506770_3000 E 22nd st 14-14-20. Install new 1' service line on southwest center of property 6LF/EM
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2023 commercial building permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
Most recent permit on record for this parcel: 2026-06-12 (TS-PRM-0626-00218) — Install one lighted wall sign and replace faces in freestanding sign.
Permit history (20)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-06-12expires 2027-01-12 | TS-PRM-0626-00218City permit record | Fence / wallInstall one lighted wall sign and replace faces in freestanding sign | Issued | |
| 2025-12-05expires 2027-07-12 | TC-COM-1225-02188City permit record | Commercial Building(NEW PERMIT FOR T21CM05589 - BROUGHT OVER INCORRECTLY FROM PERMITS PLUS)Fire Restorations & Repairs for the existing Barber Shop including repairing the exterior facade & c (200000.00) | Inspections | |
| 2025-09-04 | TS-PRM-0925-00372City permit record | Fence / wallLED Illuminated single face wall sign | Fees due | |
| 2023-03-23finaled | TR-UTL-0323-01160City permit record | Right-of-Way (ROW) - UtilityWO#2506770_3000 E 22nd st 14-14-20. Install new 1' service line on southwest center of property 6LF/EM | Complete | |
| 2023-01-30finaled | TR-ROW-0123-00312City permit record | Right-of-Way (ROW)Remove 25” driveway entrance and replace 1’W X 25’L of asphalt and new 25’L curb and gutter to match existing curb and gutter. *** | Complete | |
| 2023-01-13finaled | TC-COM-0123-00471City permit record | Commercial BuildingThe store caught on Fire causing it to close. Interior tenant improvement to a shell building, work will include installation of fixtures, office desks, finishes, reach-in coolers/freezers, Minor MEP work REVIEWERS Notes: According to the scope of work detailed on the plans, the structure, rooms, floor and ceiling, MEP, toilet rooms, etc. were all part of a prior permit (T21CM05961). The signs are the only deferred submittal. | Complete | |
| 2023-01-12expired 2023-11-11 | TS-PRM-0123-00124City permit record | Fence / wallInstall one lighted wall sign | Issued | |
| 2021-12-01expires 2027-08-12 | T21CM09272City permit record | Commercial BuildingWe are filling in the gap in the center between the newly relocated/replace Family Dollar Store whic | Issued |
Show 12 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2021-07-22finaled | T21CM05961City permit record | Commercial BuildingReplace the entire recently completed building remodel and interior T.I. for the Family Dollar Store | Complete | |
| 2021-07-09expired 2025-12-13 | T21CM05589City permit record | Commercial BuildingVoid - this permit can be continued with TC-COM-1225-02188 (3000 E 22nd ST Unit:111 Tucson, AZ 85713). The permit transfered from old permit software as the wrong permit type. Fire Restorations & Repairs for the existing Barber Shop including repairing the exterior facade & c | Void | |
| 2021-07-09expired 2025-09-05 | T21CM05610City permit record | Commercial BuildingFire Restorations & Repairs to existing retail store including damaged exterior canopy & roof T21DV0 | Issued | |
| 2021-05-11expired 2022-11-08 | T21BU00252City permit record | DemolitionDemolish and remove remaining building portion for Family Dollar Store behind recent exterior faceli | Issued | |
| 2021-03-04expired 2021-08-31 | T21OT00161City permit record | Fence / wall1- illum wall sign | Expired | |
| 2020-03-03 | T20CM01442City permit record | Commercial BuildingW - OVERHEAD TO UNDERGROUD ELECTRICAL | Expired | |
| 2019-12-19expired 2020-06-16 | T19OT01184City permit record | Fence / wall2-ILLUM WALL SIGN | Expired | |
| 2017-09-01finaled | DP17-0215City permit record | New constructionSITE/GRADING/SWPPP - El Campo Center, Revise parking lot, add new building. | Complete | |
| 2013-03-07completed 2015-05-05 | T13SE00026Special exception | Zoning Examiner Special ExceptionSE-13-26 AT&T - 22nd Street - New wireless communication facility with 65-foot monopalm in rear of shopping center. - New wireless comm. facility w/monopalmSE-13-26 AT&T - 22nd Street | Approved | |
| 2008-05-02expired 2009-05-02 | T08OT01075City permit record | PEDDLERRegulated Peddler/Hot Dogs Obregon- LlICENSE RENEWAL | Expired | |
| 2005-04-18expired 2006-04-18 | T05OT00923City permit record | PEDDLERREGULATED PEDDLER FOOD HOT DOG | Expired | |
| 2000-02-07finaled | T00ME00125City permit record | MECHPRESSURE VESSEL CERTIFICATE:TUC-23792 | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (4)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2021-03-20 | T21DV01576Housing code violation | EMERGENCYrecorded before 2023 | COMPLIAN |
| 2010-04-20 | T10DV02398Code enforcement case | Code enforcement case | Void |
| 2010-01-14 | T10DV00235Housing code violation | COM: VACANT & ABANDONEDNotice of violation issued · recorded before 2023 | COMPLIAN |
| 2008-08-05 | T08DV06740Code enforcement case | Vegetation | Cancel |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, once. No list, no follow-up unless you ask for it.
How this report was built
This is a reading of public records for parcel 13002003B — 20 permits on file from 2000 to 2026 (7 commercial building, 5 fence / wall, 2 peddler, 1 right-of-way (row) - utility) and 4 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.