2160 E Broadway Bl

Build year not published — permits on file from 2010 · HVAC 2026 (finaled)

Parcel
12904158F
Built
2010 (earliest permit on file)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Supermarket Groceries
Parcel size
0.78 acres
Sewer
Connection on file (2025) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Sunshine Mile Historic District — National Register district (City of Tucson)

See the property

County aerial photograph centered on 2160 E Broadway Bl, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire construction permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalCurrentLast permitted this year (2026). City inspection record: COT - FCON - Alarm - Final approved 2026-04-02. Applicant on the permit: Bosch Building Technologies Office. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. TF-FCP-0226-00104 — PROVIDE AND INSTALL REQUIRED FIRE LIFE SAFETY DEVICES FOR THE CONTINUED PROTECTION AT THE TRADER JOE'S. THE EXISTING SPRINKLER MONITORING PANEL WILL BE RELOCATED TO THE EQUIPMENT PLATFORM. ONE ANNUNCIATOR WILL BE PROVIDED. ROOF TOP UNIT DUCT DETECTORS WILL BE MONITORED BY FIRE ALARM SYSTEM
  • Fire alarm & life safetyCurrentLast permitted this year (2026). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0426-00246 — Fire Alarm MONITORING
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Worth confirming

    A pool or spa was permitted in 2025. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Era-based check

    A capacity and condition review is the usual starting point before any tenant improvement or added load. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (3)

Recorded transfers from the Pima County Assessor — 3 of 3
DatePriceType
2023-07-05$1,650,000Warranty Deed
2011-11-18$1,517,400Warranty Deed
2011-06-07$930,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-04-17 (TR-UTL-0426-00679) — PRJ314266-1: Cox to overlash 1,650 of CATV fiber for system tie. (Start Date 7/20/2026 - Per Direction of Prop 411 PM).

Permit history (30)

Permit history for this parcel — 8 of 30 records
DateRecordWhatStatusValue
2026-04-17expires 2026-10-18TR-UTL-0426-00679City permit recordRight-of-Way (ROW) - UtilityPRJ314266-1: Cox to overlash 1,650 of CATV fiber for system tie. (Start Date 7/20/2026 - Per Direction of Prop 411 PM)Inspections
2026-04-15expired 2026-05-17TC-CFO-0426-00074City permit recordCertificate of OccupancyTHIS SUBMITTAL IS FOR THE TENANT IMPROVEMENT OF THE EXISTING 12,666 SF BUILDING FOR A PROPOSED TRADER JOE'S GROCERY STORE. THE SCOPE OF WORK IN THIS APPLICATION IS ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL FOR A TURNKEY STORE WITH CERTIFICATE OF OCCUPANCY.Issued
2026-04-15finaledTF-FCP-0426-00246City permit recordFire ConstructionFire Alarm MONITORINGComplete
2026-04-10finaledTC-CFO-0426-00067City permit recordCertificate of OccupancyPLEASE PAY FOR TCO LEVEL CHANGE UNDER TC-CFO-0426-00074 THIS SUBMITTAL IS FOR THE TENANT IMPROVEMENT OF THE EXISTING 12,666 SF BUILDING FOR A PROPOSED TRADER JOE'S GROCERY STORE. THE SCOPE OF WORK IN THIS APPLICATION IS ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL FOR A TURNKEY STORE WITH CERTIFICATE OF OCCUPANCY.Complete
2026-02-17finaledTF-FCP-0226-00104City permit recordFire ConstructionPROVIDE AND INSTALL REQUIRED FIRE LIFE SAFETY DEVICES FOR THE CONTINUED PROTECTION AT THE TRADER JOE'S. THE EXISTING SPRINKLER MONITORING PANEL WILL BE RELOCATED TO THE EQUIPMENT PLATFORM. ONE ANNUNCIATOR WILL BE PROVIDED. ROOF TOP UNIT DUCT DETECTORS WILL BE MONITORED BY FIRE ALARM SYSTEMComplete
2026-01-22finaledTS-PRM-0126-00023City permit recordFence / wallInstall two lighted wall signs and replace tenant panels in monument sign.Inspections complete
2025-12-02TF-FCP-1225-01009City permit recordFire ConstructionVOID - Submit under Permit#TF-FCP-0725-00571 - Modification of the existing wet pipe fire sprinkler systemVoid
2025-11-20finaledTR-UTL-1125-01997City permit recordRight-of-Way (ROW) - Utility4' x 6' BELL HOLE IN PAVEMENT/DIRT TO INSTALL NEW GAS SERVICEComplete
Show 22 older records
Permit history for this parcel — remaining 22 records
DateRecordWhatStatusValue
2025-10-22finaledTF-FCP-1025-00918City permit recordPool / spaEXPEDITE - PROVIDE AND INSTALL REQUIRED FIRE LIFE SAFETY DEVICES FOR THE CONTINUED PROTECTION AT THE TRADER JOE'S SHELL SPACE. DEVICES LOCATED OUTSIDE THE SCOPE OF WORK ARE EXISTING AND TO REMAIN UNCHANGED. ONE NEW PANEL WILL BE INSTALLED TO MONITOR SPRINKLER SYSTEMS.Complete
2025-09-18finaledTR-UTL-0925-01598City permit recordRight-of-Way (ROW) - UtilityInstalling a 4" fire protection service and a 2" water service with 1.5" meter, 4-System AbandonmentsComplete
2025-08-18finaledTF-FCP-0825-00667City permit recordFire ConstructionApplying for permit to construct UG private fire line. Fire Line to be installed by: M L Kelly Contracting ROC315369 520-977-1575Complete
2025-07-15finaledTF-FCP-0725-00571City permit recordFire ConstructionInstallation of a new wet pipe fire sprinkler system for shell only.Complete
2025-05-12expired 2025-07-20TR-UTL-0525-00762City permit recordRight-of-Way (ROW) - UtilityWO T124885 - TEP to Remove 4 OH poles and relocate them to the South, But only 2 poles will be installed.Inspections
2025-03-27finaledTC-UTL-0325-00022City permit recordUtilitiesNew commercial building for food & beverage salesInspections complete
2025-03-27expired 2026-06-08TS-PRM-0325-00124City permit recordSign - PermanentInstall one lighted monument sign.Inspections
2025-03-17TS-PRM-0325-00113City permit recordSign - PermanentVOID : The Development Plan has not yet been Approved and Paid for. We will VOID this sign permit. Please resubmit a NEW one when the Development Plan has ben approved and paid for. Per Brian W. Install one lighted monument signVoid
2025-01-10finaledTC-COM-0125-00077City permit recordCommercial BuildingTHIS SUBMITTAL IS FOR THE TENANT IMPROVEMENT OF THE EXISTING 12,666 SF BUILDING FOR A PROPOSED TRADER JOE'S GROCERY STORE. THE SCOPE OF WORK IN THIS APPLICATION IS ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL FOR A TURNKEY STORE WITH CERTIFICATE OF OCCUPANCY.Complete
2024-11-06expired 2025-05-05TC-COM-1124-02133City permit recordPool / spaVOID - Wrong Work Class - Remodel existing structure for retail spaceVoid
2024-11-06finaledTC-COM-1124-02135City permit recordCommercial BuildingNew Retail Shell BldgComplete
2024-11-06finaledTD-DEV-1124-00301City permit recordDevelopment PackageRev 1 - Started 09.14.2025 ** New commercial building for food & beverage salesComplete
2022-04-19finaledT22RW01547City permit recordPool / spaWO# 6351833 TEP will be working in ROW to install overhead equipment on existing TEP pole, will be installing conductor in customer provided duct and installing new meter on customer provided meter pedestal.Will work on the existing General Contractor for the TCP or if traffic has changed due to City project changes. 2190 E BROADWAY IS THE ACTUAL ADDRESS BUT DO TO THE FACT THIS ADRESS CANT BE FOUND IN PERMITS PLUS 2160 E BROADWAY WILL BE USED AS THE ALTERNATE ADDRESS. BUS STOP IN THE AREA, CONTACT SUN TRAN DISPATCH, AT 520-206-8934 AND/OR BEA PAULUS AT 520-206-8826 AT LEAST 48-BUSINESS HOURS PRIOR TO START OF WORK FOR COORDINATION.Final
2022-03-30finaledT22RW01221City permit recordROWWO# 6359839 TEP will be removing 1 pole in the ROW a 2'x2' hole/s 6' deep will be backfilled with/out sidewalk impact @2LF. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRATIVE MANUAL.Final
2021-09-07finaledT21CM07206City permit recordCOMBOvehicle ran into building, now needs to be repairedFinal
2020-08-05finaledT20RW04452City permit recordROWTEP will be replacing 1 pole along the south side of Broadway west of Plummer. The new pole will be roughly the same size and diameter of the existing pole it is replacing. There will be no impact to sidewalk. WORK IS BEING DONE IS IN A CIP ( CAPITAL INPROVEMENT PROJECT ) MAKE CONTACT WITH AJ SCHEETZ - ascheetz@ashtoncoinc.comFinal
2017-01-12finaledDP17-0011City permit recordDevelopment PackageSITEComplete
2016-03-08finaledT16OT00311City permit recordSIGNBANNER 45 DAYSFinal
2015-08-14expired 2016-04-25T15OT01083City permit recordSIGNBANNER 45 DAYSExpired
2015-07-23T15EL00126City permit recordELECTInstallation of three new electrical circuits for walk-in cooler and freezer.Withdrwn
2015-07-23T15EL00127City permit recordELECTInstallation of new electrical circuits for walk-in cooler and freezer.Withdrwn
2015-07-16expired 2016-01-18T15OT00932City permit recordFence / wall2- ILLUM WALL SIGNSExpired

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (8)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 8 records
DateRecordWhatStatus
2025-10-29CE-VIO1025-04786Code enforcement caseCode enforcement caseClosed - unfounded
2025-06-13CE-VIO0625-02619Code enforcement caseSignClosed - unfounded
2021-04-05T21DV01846Code enforcement caseRefuseComplian
2019-07-24T19DV05982Code enforcement caseRefuseComplian
2014-09-15T14DV07371Code enforcement caseVegetationComplian
2014-06-11T14DV03846Code enforcement caseCode enforcement caseComplian
2013-08-13T13DV05927Code enforcement caseWork without permitComplian
2010-03-18T10DV01420Housing code violationWEEDSNotice of violation issued · recorded before 2023COMPLIAN

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 12904158F — 30 permits on file from 2015 to 2026 (5 fire construction, 4 right-of-way (row) - utility, 3 pool / spa, 2 certificate of occupancy) and 8 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.