Electrical permit history — 58 S Country Club Rd
58 S Country Club Rd, Tucson — built 1941, with 14 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
58 S Country Club Rd
Built 1941 — 1940s commercial stock · 14 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 58 S Country Club Rd (aztucsonelectricalsolutions.com/property/12902001a/58-s-country-club-rd-tucson-az-85716) · Public records last checked 2026-08-16
- Parcel
- 12902001A
- Built
- 1941 (assessor record)
- Jurisdiction
- Tucson
- Zoning
- HL-PAD-19
- Assessor use
- Retail Strip Center
- Parcel size
- 1.79 acres
- Building area
- 29,903 sq ft (assessor record)
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Sunshine Mile Historic District — Historic Landmark — Contributing (City of Tucson)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
A pool or spa was permitted in 2025. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.
Most recent permit on record for this parcel: 2025-10-03 (TR-ROW-1025-01228) — Place 5280 ft of aerial fiber on existing plant on power poles for First Digital Telecom.
Permit history (14)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2025-10-03finaled | TR-ROW-1025-01228City permit record | Right-of-Way (ROW)Place 5280 ft of aerial fiber on existing plant on power poles for First Digital Telecom | Complete | |
| 2025-08-20expires 2026-11-25 | TS-PRM-0825-00350City permit record | Sign - PermanentFurnish & install (2) LED illuminated reverse channel letters on a raceway. | Issued | |
| 2025-06-18finaled | TC-COM-0625-01180City permit record | Pool / spaChange of intended use of existing space from a previous hair salon spa to a PIlates Studio, without performing any interior structural modifications. Only changes made to the space is paint , the removal of a pedicure station , and 3 sinks at hair wash station location. Everything else stays exactly the same. I do not know exactly if a new certificate of occupancy is needed if there is a change of intended use of the space. We do have the original plans as reference that were submitted to us from the original buildout in 2008. Nothing has changed to my knowledge since. | Complete | |
| 2025-02-23finaled | TR-ROW-0225-00248City permit record | Right-of-Way (ROW)On Sunday, April 6th, Living Streets Alliance will host its 22nd Cyclovia Tucson event, having participants enjoy one of Tucson's Bike Boulevards from Broadway Village to La Madera Park. It connects the neighborhoods of La Madera, Country Glenn, Blenman-Elm, Sam Hughes, and Broadmoor-Broadway which are part of Ward 3 and Ward 6. The route will have activities at La Madera Park, Himmel Park, and 2 other pocket parks in Blenman-Elm and Country Glenn. Over 45 other nonprofit organizations and NGOs, local businesses, and community partners will bring the 3 mile route to life, providing a free, fun, car-free day for an anticipated 50,000 people from across the region to enjoy. | Complete | |
| 2024-12-10finaled | TS-PRM-1224-00538City permit record | Sign - Permanentneeds Marias approval its pad 19 | Inspections complete | |
| 2024-07-22finaled | TR-ROW-0724-00835City permit record | Right-of-Way (ROW)SEAL COATING OUT TO ROW *** | Complete | |
| 2023-11-27 | TR-ROW-1123-01384City permit record | Right-of-Way (ROW)Requesting a ROW permit for new sidewalk surrounding existing TRE Patio approved during COVID | Fees due | |
| 2021-10-27expired 2023-07-03 | T21OT00779City permit record | Fence / wall2- non illum wall signs | Issued |
Show 6 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2021-06-01expired 2023-06-23 | T21OT00433City permit record | Fence / wall**NEON - NEEDS DAVID MUNIZ ** New wall signage on south elevation of Natural Grocers (facing Manch | Expired | |
| 2020-12-24expired 2025-12-19 | DP20-0267City permit record | Addition / alterationSITE - Sidecar Tre Patio Addition. | Issued | |
| 2020-11-10finaled | T20RW06119City permit record | Pool / spaBARRICADE PLAN FOR NEW PATIO INSIDE TEMPORARY REVOCABLE EASEMENT INSTALLATION OF ELEVATED WOOD DECK WITH RAILINGS IN PARKING SPACES ALONG THE EAST SIDE OF S EASTBOURNE AV NORTH OF E MANCHESTER ST AND SOUTH OF E BROADWAY BL. NO CHARGE PERMIT PER DTM REAL ESTATE - RESTAURANT EXPANSION WITHIN TRE | Final | |
| 2020-05-07finaled | T20RW02590City permit record | ROWROAD CLOSURE DUE TO CRACK SEAL, POLYCHIP AND FOG SEAL UP TO DRIVE LANE ENTRANCES FOR BROADWAY VILLAGE. ADDRESS ON APPLICATION: 3050 E BROADWAY BL BUS STOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-206-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 24-HOURS PRIOR TO START OF WORK FOR COORDINATION. PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTAINED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. | Final | |
| 2018-10-26expired 2019-08-05 | T18OT01126City permit record | Fence / wall2-ILLUM WALL SIGN (HL site - requires historic review - Joesler bldg) | Expired | |
| 2015-06-23finaled | DP15-0097City permit record | Development PackageBROADWAY VILLAGE Originally approved 9.03.15 (12 pages)1st Revision approved 12.14.16 (Pages 3 | Complete |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (3)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2021-01-21 | T21DV00333Housing code violation | HOMELESS CAMPSrecorded before 2023 | REFERRED |
| 2015-10-29 | T15DV08306Housing code violation | WORK WITHOUT PERMITS-COMMERCLrecorded before 2023 | NOVERIFY |
| 2009-05-19 | T09DV02863Housing code violation | ENVIRONMENTALrecorded before 2023 | COMPLIAN |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, once. No list, no follow-up unless you ask for it.
How this report was built
This is a reading of public records for parcel 12902001A — 14 permits on file from 2015 to 2025 (4 right-of-way (row), 3 fence / wall, 2 sign - permanent, 2 pool / spa) and 3 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.
