Electrical permit history — 6135 E 22nd St

6135 E 22nd St, Tucson — built 1969, with 22 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

6135 E 22nd St

Built 1969 — 1960s commercial stock · 22 permits on record; no permitted panel/service or HVAC work among them

Parcel
12801047A
Built
1969 (county record)
Jurisdiction
Tucson
Zoning
C-1
Assessor use
Restaurant Sit Down
Parcel size
0.94 acres
Building area
2,133 sq ft (assessor record)
Sewer
Connection on file (1980) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 6135 E 22nd St, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2013 combo permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2013 combo permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Food service carries heavy, cycling kitchen loads and exhaust interlocks. Capacity and existing panel space are the first things to verify on any remodel.

Most recent permit on record for this parcel: 2019-06-27 (T19FO00497) — OCC LOAD- 71.

Permit history (22)

Permit history for this parcel — 8 of 22 records
DateRecordWhatStatusValue
2019-06-27finaledT19FO00497City permit recordFIREOPEROCC LOAD- 71Final
2015-09-22finaledT15OT01280City permit recordC-OF-OC OF O- RESTAURANTC of o
2015-08-28expired 2016-11-01T15OT01155City permit recordSIGN45 DAY BANNER 08/31/2015-10/15/2015Closed
2015-08-20T15OT01112City permit recordSIGNSIGNWithdrwn
2015-08-20finaledT15OT01113City permit recordSIGNSIGN IS MADE UP OF THREE CABINETS - 2 X 10, 10 X 10 AND 2 X 10. CHANGE OF COPY DP 8/26/12Final
2015-08-07finaledT15BU00910City permit recordBUILDFIXED SYSTEMFinal
2014-08-08expired 2014-10-07T14EX00871City permit recordEXCAV(2) 5'X5' IN DIRT, IN ALLEY, IN REAR-TO REPAIR GAS LINEClosed
2014-08-08T14TC01823City permit recordBARRICAD(2) 5'X5' IN DIRT, IN ALLEY, IN REAR-TO REPAIR GAS LINEClosed
Show 14 older records
Permit history for this parcel — remaining 14 records
DateRecordWhatStatusValue
2013-11-08finaledT13CM06822City permit recordCOMBOFIRE DAMAGE REPAIR - T13DV05153L of c
2013-06-12expired 2014-06-12T13OT00696City permit recordPEDDLERRegulated Peddler: Super Tacos Y Hot DogsExpired
2012-05-01finaledT12OT00691City permit recordSIGNCHANGE OF COPY 20444Final
2007-10-22finaledT07BU02232City permit recordBUILDFIRE HOOD SUPPRESSION SYSTEMFinal
2006-08-11finaledT06OT02100City permit recordSIGN11632Final
2006-07-20expired 2007-02-10T06OT01903City permit recordC-OF-OC OF O: TONI'S RESTAURANTClosed
2005-12-19T05BU02969City permit recordSPKLRKITCHEN EXHAUST HOODWithdrwn
2005-12-19finaledT05BU02971City permit recordBUILDKITCHEN EXHAUST HOODFinal
2005-09-07finaledT05CM04615City permit recordCOMBOFIRE DAMAGE REPAIR - RESTAURANTFinal
2003-05-13finaledT03OT00841City permit recordSIGNSIGN:5496Final
2003-05-13finaledT03OT00842City permit recordSIGNSIGN:5497Final
2002-11-07finaledT02OT01767City permit recordSIGNSIGN:4729Final
1999-01-11finaledT99EL00068City permit recordELECTREPAIR:FIRE DAMAGE:ELECTRIC REPLACE 2 CIRCUITFinal
1998-12-11expired 1999-08-28T98CM05525City permit recordCOMBOREPAIR:FIRE DAMAGE:EXHAUST HOODExpired

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (8)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 8 records
DateRecordWhatStatus
2024-01-19CE-VIO0124-00293Code enforcement caseRefuseClosed - resolved
2019-11-05T19DV08674Code enforcement caseRefuseComplian
2017-01-11T17DV00132Code enforcement caseCode enforcement caseComplian
2015-03-09T15DV01790Code enforcement caseVegetationComplian
2015-03-05T15DV01631Code enforcement caseVegetationReferred
2014-09-26T14DV08011Code enforcement caseCode enforcement caseComplian
2013-07-18T13DV05153Code enforcement caseFireComplian
2008-07-28T08DV06464Code enforcement caseVegetationCancel

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 12801047A — 22 permits on file from 1998 to 2019 (8 sign, 3 build, 3 combo, 2 c-of-o) and 8 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.