Electrical permit history — 5150 E Speedway Bl

5150 E Speedway Bl, Tucson — built 2005, with 25 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

5150 E Speedway Bl

Built 2005 — 2000s commercial stock · 25 permits on record; no permitted panel/service or HVAC work among them

Parcel
127022350
Built
2005 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Auto/Light Truck Lot Lease Or Sale
Parcel size
0.71 acres
Building area
3,675 sq ft (assessor record)
Sewer
Connection on file (1957, 2008) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 5150 E Speedway Bl, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2002 combo permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2002 combo permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2001. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

Most recent permit on record for this parcel: 2024-04-18 (TR-UTL-0424-00826) — wo#2595714 5150 e speedway bl 14-14-11 ne replace fh ne corner of lot in dirt easement 6LF/sc.

Permit history (25)

Permit history for this parcel — 8 of 25 records
DateRecordWhatStatusValue
2024-04-18TR-UTL-0424-00826City permit recordRight-of-Way (ROW) - Utilitywo#2595714 5150 e speedway bl 14-14-11 ne replace fh ne corner of lot in dirt easement 6LF/scNeeds resubmittal
2020-07-14finaledT20RW04076City permit recordROWSIDEWALK CLOSURE - WE ARE ELIMINATING THE NORTH-EAST ENTRY OFF MAGNOLIA. WE WILL REMOVE SIDEWALK AND ASPHALT AND POUR TO MATCH EXISTING SIDEWALK AND CURBFinal
2020-06-25finaledT20OT00448City permit recordFence / wall1-illum wall signFinal
2020-03-16finaledT20CM01720City permit recordCOMBOOFFICEC of o
2020-02-13finaledDP20-0037City permit recordDevelopment PackageSITE - Enterprise Speedway, reconfigure and add to parking lot.Complete
2017-05-18finaledT17RW02125City permit recordROWCURB LANE, BIKE LANE AND SIDEWALK WILL BE ONLY AREAS THAT WILL BE AFFECTED ASPHALT WILL BE REPLACED FROM CURB TO WHITE BIKE LANEFinal
2016-12-27finaledT16CM09619City permit recordCOMBOCANOPY OVER EXITING CARWASH LANEC of o
2016-09-13expired 2017-03-20T16OT01130City permit recordFence / wall1-ILLUM WALL SIGN & 4- NON ILLUM DDExpired
Show 17 older records
Permit history for this parcel — remaining 17 records
DateRecordWhatStatusValue
2016-08-23expired 2017-02-20T16OT01032City permit recordSIGNCofC ON DF SIGNExpired
2006-02-15finaledT06OT00462City permit recordSIGN10661Final
2006-01-20finaledT06OT00170City permit recordSIGN10465Final
2005-12-07expired 2006-02-05T05EX01435City permit recordEXCAVINSTALL IMPROVEMENTS IN THE R/W PER APPROVED GRADIClosed
2005-11-30finaledT05OT02951City permit recordSIGN10136Final
2005-10-13expired 2005-12-12T05EX01174City permit recordEXCAVINSTALL HCS PER PIMA COUNTY REQUIREMENTS AND BACKFClosed
2005-06-10finaledT05BU01477City permit recordGRADINGGRADINGFinal
2005-06-07finaledT05CM02611City permit recordCOMBONEW: CAR WASHC of o
2005-05-20expired 2006-01-31T05OT01284City permit recordSITESITE PLANExpired
2005-03-04expired 2005-09-03T05BU00501City permit recordDemolitionDEMOLITION:COMMERCIAL BLDG.Expired
2002-11-27finaledT02OT01875City permit recordSIGNSIGN:4808Final
2002-10-22finaledT02CM04896City permit recordCOMBOREMODEL:SHELLFinal
2002-01-16T02CM00246City permit recordCOMBOTI:NIGHT CLUBWithdrwn
2001-12-31finaledT01EL03001City permit recordELECTRECONNECT:ELECTRIC:NIGHT CLUBFinal
2001-10-29T01OT00810City permit recordC-OF-OC OF O: BARWithdrwn
2001-04-17expired 2001-10-17T01EL00894City permit recordELECTELECTRIC SERVICE:RECONNECTExpired
1999-02-11finaledT99OT00046City permit recordC-OF-OC OF O INSPECTION:BARC of o

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (13)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 13 records
DateRecordWhatStatus
2025-06-20CE-VIO0625-02683Code enforcement caseRefuseClosed - unfounded
2023-01-05CE-VIO0123-01259Code enforcement caseRefuseClosed - unfounded
2022-01-13T22DV00315Code enforcement caseRefuseNoverify
2020-07-08T20DV04608Code enforcement caseCode enforcement caseComplian
2019-11-13T19DV08846Code enforcement caseCode enforcement caseComplian
2018-12-27T18DV08241Code enforcement caseCode enforcement caseComplian
2013-06-14T13DV04170Code enforcement caseZoningNoverify
2012-12-19T12DV11222Code enforcement caseCode enforcement caseComplian
Show 5 older records
Code enforcement history for this parcel — remaining 5 records
DateRecordWhatStatus
2011-08-30T11DV06937Code enforcement caseVegetationReferred
2010-10-12finaledT10FR02067Code enforcement caseCode enforcement caseComplete
2008-07-15finaledT08FR01900Code enforcement caseCode enforcement caseComplete
2004-11-08T04ZV00814Code enforcement caseCode enforcement caseReferred
2002-10-08T02VL02045Code enforcement caseWork without permitClosed

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 127022350 — 25 permits on file from 1999 to 2024 (5 combo, 5 sign, 2 row, 2 fence / wall) and 13 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.