Electrical permit history — 445 S Alvernon Wy
445 S Alvernon Wy, Tucson — built 1976, with 102 permits on record. Review electrical, HVAC and remodel history with links to official records.
Electrical Property Screening Report · Commercial property
445 S Alvernon Wy
A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.
Verify parcel data at official source ↗
Built 1976 — 1970s commercial stock · last permitted panel/service work 2016 (finaled) · HVAC 2018 (finaled); a newer 2019 permit is expired without a final · 1 open code case
Permanent link: Electrical permit history for 445 S Alvernon Wy (aztucsonelectricalsolutions.com/property/12616319d/445-s-alvernon-wy-tucson-az-85711) · Public records last checked 2026-09-22
Is it time to upgrade?
- Electrical service & distributionFinaled permit foundLast permitted 2016 (10 years ago). The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T16CM06785 — 100 TO 200 AMP UPGRADE
- Heating, cooling & mechanicalFinaled permit foundA newer 2019 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “HVAC UPGRADE”. Last permitted 2018 (8 years ago). Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T18CM02603 — CHILLER/ REPLACEMENT
- Fire alarm & life safetyFinaled permit foundLast permitted 2020 (6 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T20FC00842 — Upgrading (4) ADA rooms to include sounder bases, strobes, & NAC panel to power new devices.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check
A finaled 2016 panel/service permit is on record for this parcel, which makes it unlikely the original 100–150 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Worth looking at
There is an open code enforcement case on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
A pool or spa was permitted in 2018. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.
- Routine
A trade permit was pulled in 2019. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.
Solar and energy potential
- Roof footprint
- ≈ 114,276 sq ft (county building-footprint layer, 10 structures; 3 neighbouring structures crossing the lot line excluded)
- Usable for solar, planning estimate
- ≈ 80,000 sq ft (~70% after setbacks, rooftop equipment and access paths)
- Array that could fit
- on the order of 880 kW — roughly 2,200 panels (low-tilt ballasted rows, 400 W class modules)
- Estimated annual production
- ≈ 1,450,000 kWh (PVWatts, Tucson sun, low-tilt south)
- Energy-charge offset at TEP commercial rates
- $116,000–$189,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)
Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.
TEP grid capacity — mapped saturation areaThis property sits within about half a mile of “El Con Mall - Reid Park Area”, one of 11 areas TEP has mapped as saturated with distributed generation (customer solar) relative to circuit capacity. On a saturated circuit, new solar or battery systems can trigger supplemental utility review before interconnection is approved — and a large new load such as DC fast charging or process equipment is worth a capacity conversation with TEP before a site plan hardens. The boundary here is approximate, digitized from TEP’s map of the area (PDF, July 2020); TEP’s own interconnection screening is the authority, and circuit status can have changed since the maps were published.
Get a commercial solar & switchgear analysis
See the property
Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.
Flood and drainage
The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.
- FEMA: we did not read the federal flood map for this snapshot, so no zone is shown here. That is a gap in this page, not a statement about the property. Check FEMA’s flood map for this address ↗
- Local floodplain (the City of Tucson): local floodplain mapping is not reproduced here. A property can sit outside FEMA’s zone and still be inside a locally regulated floodplain, floodway, sheet-flooding area or erosion hazard setback, so check the authority’s own map before planning work. Pima County RFCD flood hazard map for parcel 12616319D ↗ · the City of Tucson ↗
The record behind this read
- Parcel
- 12616319D
- Year constructed
- 1976 (assessor record)
- Permitting authority
- Tucson
- Zoning
- OCR-2
- Property type
- Hotel 5 Or More Stories
- Building area
- 647,162 sq ft
- Service on record
- City records show the 2016 permit was finalized; the permit description states “100 TO 200 AMP UPGRADE” — an increase in capacity as described, not a confirmed installed rating.
The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.
The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.
What this means for work here
Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.
The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.
What that reading rests on. The issuing offices hold 102 building permits for this parcel dated between 1997 and 2026. By category the work is trade permit (32), addition / alteration (20), fire automatic extinguishing system (14) and special events fire permit - organizer (7). 69 of them carry a final inspection; the other 33 were issued, expired or are still open, which is not the same as work completed. There are 16 code-enforcement cases recorded against the parcel, 1 of which is open. We do not reproduce complaint text — it routinely names people with no connection to the property.
Go straight to the records
Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.
Code enforcement cases (16): 2026 CE-VIO0826-03336 · 2024 CE-VIO0524-01641 · 2021 T21DV04952 · 2020 T20DV05138 · 2020 T20DV05139 · 2018 T18DV04656 · 2017 T17DV05283 · 2017 T17DV03506 · 2017 T17DV01566 · 2015 T15DV00581 · 2014 T14DV08691 · 2014 T14DV06020 · 2014 T14DV03310 · 2010 T10DV06111 · 2008 T08DV09865 · 2008 T08DV00719
Commercial building (2): 2026 TC-DMO-0626-00097 · 2020 T20CM02537
City permit record (100): 2025 TF-FOP-1125-01475 · 2024 TF-FOP-1124-01302 · 2023 TF-FOP-1023-01614 · 2022 T21FO00900 · 2021 T21FO00792 · 2020 T20FC00842 · 2020 T20CM06032 · 2020 T20CM00519 · 2020 T20FO00004 · 2019 T19CM08907 · 2019 T19FO00877 · 2019 T19FC00738 · 2019 T19CM06129 · 2019 T19FC00594 · 2019 T19CM04530 · 2019 T19CM04459 · 2019 T19OT00273 · 2019 T19FC00174 · 2019 T19FC00104 · 2019 T19FO00022 · 2018 T18CM02231 · 2018 T18CM02603 · 2018 T18BU00209 · 2018 DP18-0079 · 2018 T18CM02108 · 2017 T17FO01084 · 2017 T17FO00395 · 2017 T17FO00100 · 2017 T17FO00031 · 2016 T16SA00536 · and 70 older — search the parcel at the office below
Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 12616319D. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.
In the public record: All commercial property · Commercial property in 85711 · Commercial & industrial reports · Homes in 85711 · Permit data by neighborhood
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.
How this property compares nearby
Properties on S ALVERNON WY hold 687 City permits on record, 95 of them since 2022.
Computed from the same public records as this report — counts and years, not an appraisal.
Complete permit record (118 entries)
Every permit and case we hold for this parcel, newest first. Each number links to the official file.
| Year | Number | Type | Status |
|---|---|---|---|
| 2026 | CE-VIO0826-03336 | Vegetation | Received |
| 2026 | TC-DMO-0626-00097 | Commercial Demolition Permit | Issued |
| 2025 | TF-FOP-1125-01475 | Special Events Fire Permit - Organizer | Fees Due |
| 2024 | TF-FOP-1124-01302 | Special Events Fire Permit - Organizer | Complete |
| 2024 | CE-VIO0524-01641 | Vegetation | Closed - Resolved |
| 2023 | TF-FOP-1023-01614 | Special Events Fire Permit - Organizer | Complete |
| 2022 | T21FO00900 | Special Events Fire Permit - Organizer | Complete |
| 2021 | T21FO00792 | Special Events Fire Permit - Organizer | Complete |
| 2021 | T21DV04952 | MULTIPLE TYPES | NOVERIFY |
| 2020 | T20FC00842 | Fire Alarm System Permit | Complete |
| 2020 | T20CM06032 | Commercial Trade Permit | Expired |
| 2020 | T20DV05138 | OBSTR DEAD TREES AND SHRUBS | NOVERIFY |
| 2020 | T20DV05139 | MULTIPLE TYPES | NOVERIFY |
| 2020 | T20CM02537 | Commercial Addition/Alteration Permit | Approved |
| 2020 | T20CM00519 | Commercial Addition/Alteration Permit | Expired |
| 2020 | T20FO00004 | General Operational Fire Permit | Complete |
| 2019 | T19CM08907 | Commercial Trade Permit | Complete |
| 2019 | T19FO00877 | General Operational Fire Permit | Complete |
| 2019 | T19FC00738 | Fire Automatic Extinguishing System Permit | Complete |
| 2019 | T19CM06129 | Commercial Trade Permit | Withdrawn |
| 2019 | T19FC00594 | Fire Automatic Extinguishing System Permit | Complete |
| 2019 | T19CM04530 | Commercial Trade Permit | Expired |
| 2019 | T19CM04459 | Commercial Trade Permit | Canceled |
| 2019 | T19OT00273 | Permanent Sign Permit | Complete |
| 2019 | T19FC00174 | Fire Alarm System Permit | Complete |
| 2019 | T19FC00104 | Fire Automatic Extinguishing System Permit | Complete |
| 2019 | T19FO00022 | Special Events Fire Permit - Organizer | Complete |
| 2018 | T18DV04656 | PROP MAINT MULTIPLE TYPES | COMPLIAN |
| 2018 | T18CM02231 | Commercial Addition/Alteration Permit | Complete |
| 2018 | T18CM02603 | Commercial Trade Permit | Complete |
| 2018 | T18BU00209 | Commercial Pool/Spa Permit | Complete |
| 2018 | DP18-0079 | Development Package | Complete |
| 2018 | T18CM02108 | Commercial Addition/Alteration Permit | Withdrawn |
| 2017 | T17FO01084 | General Operational Fire Permit | Complete |
| 2017 | T17DV05283 | WEEDS | COMPLIAN |
| 2017 | T17DV03506 | MULTIPLE TYPES | COMPLIAN |
| 2017 | T17FO00395 | Special Events Fire Permit - Organizer | Complete |
| 2017 | T17DV01566 | PROP MAINT MULTIPLE TYPES | COMPLIAN |
| 2017 | T17FO00100 | General Operational Fire Permit | Complete |
| 2017 | T17FO00031 | Special Events Fire Permit - Vendor | Complete |
| 2016 | T16SA00536 | Zoning Compliance | Complete |
| 2016 | T16CM04111 | Commercial Trade Permit | Complete |
| 2016 | T16CM06785 | Commercial Trade Permit | Complete |
| 2016 | T16CM06739 | Commercial Trade Permit | Canceled |
| 2016 | T16OT01085 | Floodplain Use Permit | Complete |
| 2016 | T16TUP0008 | Temporary Use Permit | Canceled |
| 2016 | T16SE00072 | Mayor Council Special Exception | Approved |
| 2015 | T15CM06354 | Commercial Trade Permit | Complete |
| 2015 | T15DV00581 | COMMERCIAL ZONING | COMPLIAN |
| 2014 | T14CM07710 | Commercial Trade Permit | Complete |
| 2014 | T14DV08691 | FIRE AT COMMERCIAL BUILDING | COMPLIAN |
| 2014 | T14DV06020 | SIGN VIOLATION | COMPLIAN |
| 2014 | T14DV03310 | SIGN VIOLATION | COMPLIAN |
| 2013 | T12BU00861 | Commercial Trade Permit | Canceled |
| 2012 | T12BU00648 | Commercial Trade Permit | Canceled |
| 2012 | T12EL00123 | Commercial Trade Permit | Complete |
| 2011 | T11OT02351 | Permanent Sign Permit | Complete |
| 2011 | T11OT02161 | Permanent Sign Permit | Complete |
| 2011 | T11BU01081 | Fire Automatic Extinguishing System Permit | Canceled |
| 2011 | T11CM02544 | Commercial Addition/Alteration Permit | Withdrawn |
| 2011 | T11BU00811 | Fire Automatic Extinguishing System Permit | Complete |
| 2011 | T11CM01064 | Commercial Trade Permit | Canceled |
| 2011 | T11CM01221 | Commercial Addition/Alteration Permit | Canceled |
| 2011 | T11CM00148 | Commercial Trade Permit | Canceled |
| 2010 | T10DV06111 | ENVIRONMENTAL | REFERRED |
| 2010 | T10CM00420 | Commercial Trade Permit | Canceled |
| 2010 | T10SE00069 | Mayor Council Special Exception | Approved |
| 2010 | T10EL00160 | Commercial Trade Permit | Complete |
| 2010 | T10EL00070 | Commercial Trade Permit | Complete |
| 2009 | T09SE00030 | Mayor Council Special Exception | Approved |
| 2009 | D08-0036 | Development Package | Expired |
| 2009 | T09OT01070 | Floodplain Use Permit | Withdrawn |
| 2009 | T09CM00186 | Commercial Trade Permit | Complete |
| 2008 | T08DV09865 | COMMERCIAL ZONING | COMPLIAN |
| 2008 | T08BU01644 | Commercial Fence/Wall Permit | Complete |
| 2008 | T08BU01371 | Grading | Withdrawn |
| 2008 | T08EL01162 | Commercial Trade Permit | Complete |
| 2008 | T08CM01819 | Commercial Addition/Alteration Permit | Complete |
| 2008 | T08CM02236 | Commercial Addition/Alteration Permit | Complete |
| 2008 | T08CM01059 | Commercial Trade Permit | Complete |
| 2008 | T08CM00763 | Commercial Trade Permit | Withdrawn |
| 2008 | T08DV00719 | COMMERCIAL ZONING | COMPLIAN |
| 2007 | T07CM04229 | Commercial Addition/Alteration Permit | Withdrawn |
| 2007 | T07OT02198 | Permanent Sign Permit | Complete |
| 2007 | T07OT02016 | Permanent Sign Permit | Complete |
| 2007 | T07CM03577 | Commercial Addition/Alteration Permit | Complete |
| 2007 | T07EL01630 | Commercial Trade Permit | Withdrawn |
| 2007 | T07OT01660 | Permanent Sign Permit | Complete |
| 2006 | T06BU02568 | Fire Automatic Extinguishing System Permit | Complete |
| 2004 | T04CM03553 | Commercial Addition/Alteration Permit | Withdrawn |
| 2004 | T04OT01770 | Floodplain Use Permit | Withdrawn |
| 2004 | T04CM03410 | Commercial Addition/Alteration Permit | Complete |
| 2004 | T04BU01865 | Fire Automatic Extinguishing System Permit | Complete |
| 2004 | T04BU01344 | Fire Automatic Extinguishing System Permit | Complete |
| 2003 | T03BU01946 | Fire Automatic Extinguishing System Permit | Complete |
| 2003 | T03CM02613 | Commercial Addition/Alteration Permit | Complete |
| 2003 | T03OT00971 | Floodplain Use Permit | Complete |
| 2002 | T02CM02974 | Commercial Addition/Alteration Permit | Complete |
| 2002 | T02BU02397 | Fire Automatic Extinguishing System Permit | Complete |
| 2002 | T02CM03524 | Commercial Addition/Alteration Permit | Canceled |
| 2002 | T02BU01329 | Commercial Addition/Alteration Permit | Complete |
| 2001 | T01OT00289 | Permanent Sign Permit | Complete |
| 2000 | T00CM05222 | Commercial Addition/Alteration Permit | Complete |
| 2000 | T00ME01087 | Commercial Trade Permit | Complete |
| 2000 | T00OT00221 | Commercial Addition/Alteration Permit | Complete |
| 2000 | T00ME00460 | Commercial Trade Permit | Complete |
| 2000 | T00BU00260 | Fire Automatic Extinguishing System Permit | Complete |
| 2000 | T00EL00104 | Commercial Trade Permit | Withdrawn |
| 2000 | T99BU03286 | Fire Automatic Extinguishing System Permit | Complete |
| 1999 | T99BU02823 | Fire Automatic Extinguishing System Permit | Complete |
| 1999 | T99CM03834 | Commercial Addition/Alteration Permit | Complete |
| 1999 | T99CM03571 | Commercial Trade Permit | Complete |
| 1999 | T99EL00202 | Commercial Trade Permit | Withdrawn |
| 1998 | T98BU02381 | Fire Automatic Extinguishing System Permit | Complete |
| 1998 | T98ME00400 | Commercial Trade Permit | Complete |
| 1998 | T98CM01742 | Commercial Addition/Alteration Permit | Complete |
| 1997 | T97PL01855 | Commercial Trade Permit | Complete |
| 1997 | T97PL01767 | Commercial Trade Permit | Complete |
prints this report — permits, comparisons and sources — as a clean document
How this report was built
This is a reading of public records for parcel 12616319D — 102 City permits on file from 1997 to 2026 and 16 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.
The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.