Electrical permit history — 4525 E 22nd St

4525 E 22nd St, Tucson — built 1954, with 42 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

4525 E 22nd St

Built 1954 — 1950s commercial stock · last permitted panel/service work 2021 (finaled)

Parcel
126134680
Built
1954 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Warehouse W/Off/Rtl Interior @ .26-.60
Parcel size
2.01 acres
Building area
35,613 sq ft (assessor record)
Sewer
Connection on file (1955, 1956, 1979) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
City records show the 2021 permit was finalized; the permit description states “Install new feeders from TEP gutter to meter from meter to new 100 amp disconnect”.

See the property

County aerial photograph centered on 4525 E 22nd St, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentLast permitted 2021 (5 years ago). City inspection record: ELECTRIC - FINAL approved 2022-03-04. Contractor of record: high energy electric. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T21CM07765 — Install new feeders from TEP gutter to meter from meter to new 100 amp disconnect
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Industrial and warehouse space usually means three-phase motor loads. High-bay LED retrofits and added VFDs both change the load picture.

  • Worth confirming

    There is an electrical reconnect permit from 2019. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

Most recent permit on record for this parcel: 2026-05-22 (TC-FBB-0526-00069) — TEMPORARY POWER & TEMPORARY CONSTRUCTION OFFICE.

Permit history (42)

Permit history for this parcel — 8 of 42 records
DateRecordWhatStatusValue
2026-05-22finaledTC-FBB-0526-00069City permit recordFactory Built BuildingsTEMPORARY POWER & TEMPORARY CONSTRUCTION OFFICEInspections complete
2026-05-21TC-COM-0526-00760City permit recordTrade permitIf you have questions regarding this review, please contact CDRC@tucsonaz.gov. VOID: Wrong Permit Type. We were unable to intake your request under a Commercial Trade Permit. The scope of work and building type require that this request be submitted under a Permanent Modular or Shipping Container Permit. This permit will be voided. TEMPORARY POWER FOR CONSTRUCTION CONTAINER OFFICEVoid
2026-04-08expires 2027-07-28TC-COM-0426-00491City permit recordCommercial BuildingRev 1 - Started 07.24.2026 ** FIRE DAMAGE REPAIRNeeds resubmittal
2026-02-18expires 2026-08-30TC-DMO-0226-00038City permit recordDemolitionRemove fire damaged roof system in its entirety including roof material, seathing, trusses. (DEMOLITION ONLY)Needs resubmittal
2025-09-12finaledTR-ROW-0925-01120City permit recordRight-of-Way (ROW)AZTEC will perform 58 utility potholes for Tucson WaterComplete
2024-05-15expired 2024-11-27TC-COM-0524-00928City permit recordCommercial Buildingexisting meter socket for 4525 E 22nd st is burnt and needs to be replaces as soon as possible. tep was out there to confirmIssued
2021-09-28finaledT21CM07765City permit recordCOMBOInstall new feeders from TEP gutter to meter from meter to new 100 amp disconnectFinal
2019-10-23finaledT19RW06420City permit recordROW(2) 5X5 BELLHOLES IN THE DIRT TO REPLACE GAS SERVICE NOTES: This road is under a pavement moratorium, any new asphalt that is disturbed will require a 2" mill and overlay for 50' in each direction from the outside of the cut for all effected travel lanes. PLACE SIDEWALK CLOSED AHEAD AS NEEDED AT NEAREST CROSSWALK APPLICATION FOR: 4503,4509,4513 E 22nd ST CHANGED TO 4509 E 22nd STFinal
Show 34 older records
Permit history for this parcel — remaining 34 records
DateRecordWhatStatusValue
2019-05-02finaledT19CM03139City permit recordElectrical reconnectELECTRICAL RECONNECTFinal
2016-08-11expired 2017-11-04T16CM06270City permit recordCOMBOTI: HOOKAH LOUNGEExpired
2016-08-10finaledT16CM06245City permit recordCOMBOADD SEPERATE METER; COMMFinal
2016-07-08expired 2017-01-25T16CM05309City permit recordCOMBOADD SIDEWALK CANOPY FOR STRIP MALLExpired
2016-06-08expired 2017-01-16T16CM04302City permit recordCOMBODEMO FRONT CANOPY/AWNING: COMMExpired
2016-01-14finaledT16BU00054City permit recordBUILDBILLBOARD REPAIRFinal
2013-11-27expired 2014-01-26T13EX01279City permit recordEXCAVREMOVE AND REPLACE BADLY DETERIORATED MANHOLE ON BELVEDERE AV, 250'NORTH OF 22ND STREETClosed
2010-07-27finaledT10OT01597City permit recordSIGN18446Final
2010-06-28finaledT10EL01561City permit recordELECTLIGHTING MODIFICATION:ELECTRICAL REPAIRFinal
2010-06-03expired 2010-12-01T10OT01203City permit recordSIGN18446Sign-pc
2010-03-12expired 2010-10-24T10OT00565City permit recordSIGN18047Expired
2010-03-08finaledT10OT00529City permit recordC-OF-OC OF O:RETAILC of o
2010-02-11T10AN00070City permit recordADDRNEWIssued
2010-02-09finaledT10OT00308City permit recordSIGN17897Final
2009-09-02finaledT09EL02022City permit recordELECTELEC:RECON:RETAILFinal
2009-08-28finaledT09OT01817City permit recordC-OF-OC OF O: RETAIL ANTIQUESC of o
2009-04-01finaledT09EL00706City permit recordELECTELEC RECONNECTFinal
2009-03-25finaledT09EL00651City permit recordELECTRECONNECT: ELECTRIC (COMM)Final
2009-03-03finaledT09OT00447City permit recordC-OF-OC OF O: LIGHT AUTO REPAIRC of o
2007-07-16finaledT07OT01631City permit recordC-OF-OC OF O:RENTAL PROPERTY:ESTATE & FURNITURE SALESC of o
2007-06-08finaledT07OT01346City permit recordSIGN13240Final
2007-05-31finaledT07OT01278City permit recordC-OF-ONAME CHANGE C OF OC of o
2007-05-30expired 2007-12-26T07OT01263City permit recordSIGN13186Expired
2007-04-17finaledT07EL00675City permit recordELECTRECONNECT:ELECTRIC RETAILFinal
2007-04-17finaledT07OT00897City permit recordC-OF-OC OF O: AUTO REPAIRC of o
2007-01-12finaledT07EL00077City permit recordELECTELECTRIC RECONNECT: COMMERCIALFinal
2006-11-07finaledT06OT02882City permit recordC-OF-OC OF O: WINDOW TINTINGC of o
2006-10-06T06OT02615City permit recordC-OF-OC OF O: CAR AUDIO AND TINTWithdrwn
2006-02-10finaledT06OT00410City permit recordSIGN10628Final
2005-08-30T05AN00939City permit recordADDRNEWIssued
2005-08-30finaledT05OT02155City permit recordSIGNSIGN:9619 R & S AUCTIONSFinal
2002-11-26finaledT02EL02316City permit recordELECTELECTRIC:RECONNECTFinal
2000-02-14finaledT00EL00384City permit recordELECTRECONNECT:ELECTRIC DESIGN STUDIOFinal
1998-04-13finaledT98EL00632City permit recordELECTRECONNECT:ELECTRIC:WAREHOUSEFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (12)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 12 records
DateRecordWhatStatus
2025-10-01CE-VIO1025-04331Code enforcement caseFireClosed - resolved
2019-12-30T19DV09560Code enforcement caseCode enforcement caseNoverify
2017-07-31T17DV03302Code enforcement caseCode enforcement caseComplian
2017-04-10T17DV01442Code enforcement caseCode enforcement caseComplian
2014-02-24T14DV01069Code enforcement caseCode enforcement caseNoverify
2013-07-11T13DV04929Code enforcement caseGraffitiNoverify
2013-04-15T13DV02441Code enforcement caseGraffitiComplian
2010-05-20T10DV03317Code enforcement caseCode enforcement caseNoverify
Show 4 older records
Code enforcement history for this parcel — remaining 4 records
DateRecordWhatStatus
2007-11-05T07DV11922Code enforcement caseSignComplian
2007-05-03T07DV04057Code enforcement caseVegetationComplian
2007-02-26T07DV01843Code enforcement caseCode enforcement caseComplian
1999-03-15T99VL00708Code enforcement caseSignComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 126134680 — 42 permits on file from 1998 to 2026 (9 elect, 8 sign, 8 c-of-o, 5 combo) and 12 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.