Electrical permit history — 3919 E Broadway Bl
3919 E Broadway Bl, Tucson — built 1972, with 37 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
3919 E Broadway Bl
Built 1972 — 1970s commercial stock · HVAC 2005 (finaled); a newer 2015 permit is expired without a final
Permanent link: Electrical permit history for 3919 E Broadway Bl (aztucsonelectricalsolutions.com/property/126070730/3919-e-broadway-bl-tucson-az-85711) · Public records last checked 2026-08-17
- Parcel
- 126070730
- Built
- 1972 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-1
- Assessor use
- Federal Commercial Property
- Parcel size
- 0.72 acres
- Building area
- 26,288 sq ft (assessor record)
- Sewer
- Connection on file (1954) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2015 spklr permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalLikely dueA newer 2015 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “FIRE ALARM-add detection for HVAC”. Last permitted 2005 (21 years ago). City inspection record: MECHANICAL - FINAL approved 2005-09-09. Contractor of record: AIR CONDITIONING MAINTENANCE CO;*T. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Equipment from before about 2010 generally runs R-22, which has not been produced since 2020 — repairs mean reclaimed refrigerant at a price that often exceeds replacing the unit. T05ME00576 — REPLACE 2 2TON SPLIT UNITS
- Fire alarm & life safetyCurrentA newer 2015 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “FIRE ALARM”. Last permitted 2015 (11 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T15BU00164 — ADD 1 & RELOCATE16 SPRINKLERS
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
A pool or spa was permitted in 2005. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.
Recorded sales (2)
| Date | Price | Type |
|---|---|---|
| 2003-04-18 | $3,600,000 | Special Warranty Deed |
| 2000-10-17 | $2,700,000 | Special Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2019-10-25 (T19RW06492) — N.535416 - Job will bore 260' of (1) 4" PVC from HH #10833 to a new 3048 HH. NOTES: This road Av is under a pavement moratorium, any new asphalt that is disturbed will require a 2" mill and overlay for 50' in each direction from the outside of the cut for all effected travel lanes. PERMIT END DATE HAS BEEN MODIFIED DUE TO HOLIDAY RESTRICTION BEGINNING NOVEMBER 28TH 2019 - JANUARY 2ND 2020..
Permit history (37)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2019-10-25finaled | T19RW06492City permit record | ROWN.535416 - Job will bore 260' of (1) 4" PVC from HH #10833 to a new 3048 HH. NOTES: This road Av is under a pavement moratorium, any new asphalt that is disturbed will require a 2" mill and overlay for 50' in each direction from the outside of the cut for all effected travel lanes. PERMIT END DATE HAS BEEN MODIFIED DUE TO HOLIDAY RESTRICTION BEGINNING NOVEMBER 28TH 2019 - JANUARY 2ND 2020. | Final | |
| 2015-05-08 | T15BU00511City permit record | BUILDFIRE ALARM | Withdrwn | |
| 2015-04-23finaled | T15OT00537City permit record | SIGNSIGNS WILMOT PLAZA / BROADWAY / 4- ILLUM DF'S ON BROADWAY & WILMOT W/ 8- TENANT PANELS EACH. | Final | |
| 2015-03-13expired 2015-09-19 | T15BU00268City permit record | BUILDFIRE ALARM | Expired | |
| 2015-03-13finaled | T15EX00310City permit record | EXCAVTRENCH ASPHALT 20' PLACE 2" PVC CONDUIT FOR LEVEL 3 FIBER; TPD REQUIRED FOR POINT CONTROL, CROSSING 10PM -6AM ONLY | Final | |
| 2015-03-13 | T15TC00728City permit record | BARRICADTRENCH ASPHALT 20' PLACE 2" PVC CONDUIT FOR LEVEL 3 FIBER; TPD REQUIRED FOR POINT POINT, CROSSING 10PM -6AM ONLY | Expired | |
| 2015-02-24expired 2015-09-19 | T15BU00210City permit record | BUILDFIRE ALARM-add detection for HVAC | Expired | |
| 2015-02-12finaled | T15BU00164City permit record | SPKLRADD 1 & RELOCATE16 SPRINKLERS | Final |
Show 29 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2015-02-12finaled | T15BU00165City permit record | SPKLRADD 1, RELOCATE 15 FIRE SPRINKLERS | Final | |
| 2015-02-03finaled | T15BU00116City permit record | SPKLRRELOCATE 5 HEADS on third floor | Final | |
| 2014-10-06finaled | T14CM06658City permit record | COMBOT.I;OFFICE FIRST FLOOR-PHASE 1 | Final | |
| 2014-10-06finaled | T14CM06659City permit record | COMBOT.I;OFFICE SECOND LEVEL-PHASE 3 | Final | |
| 2014-10-06finaled | T14CM06661City permit record | COMBOT.I;OFFICE THIRD FLOOR - PHASE TWO | Final | |
| 2014-10-06finaled | T14CM06662City permit record | COMBOT.I;OFFICE FORTH FLOOR - PHASE 4 | Final | |
| 2012-02-22finaled | T12BU00256City permit record | SPKLRAdd 19 fire sprinklers | Final | |
| 2012-01-31finaled | T12CM00221City permit record | COMBOTI:OFFICE | Final | |
| 2011-03-30expired 2011-05-29 | T11EX00137City permit record | EXCAVTRENCHING +/- 20' TO PLACE COX COMMUNICATIONS FACILITIES WITHIN THE ROW. | Closed | |
| 2011-03-24finaled | T11BU00384City permit record | SPKLRAdd 2, relocate 18 fire sprinklers | Final | |
| 2011-02-09finaled | T11CM00441City permit record | COMBOTI and CofO: OFFICE | C of o | |
| 2011-01-25finaled | T11CM00200City permit record | COMBOTI:OFFICE | C of o | |
| 2005-10-03finaled | T05BU02436City permit record | SPKLRFIRE SPKR: RELOCATE 5 | Final | |
| 2005-08-26expired 2006-03-15 | T05BU02151City permit record | SPKLRFIRE SPKR:RELOC 4 | Expired | |
| 2005-08-24finaled | T05BU02135City permit record | SPKLRFIRE SPKR: RELOCATE 4 | Final | |
| 2005-08-16finaled | T05ME00576City permit record | MECHREPLACE 2 2TON SPLIT UNITS | Final | |
| 2005-08-15finaled | T05ME00569City permit record | MECHREPLACE: 3 - 2 1/2 TON SPLIT SYSTEMS | Final | |
| 2005-08-04finaled | T05CM04094City permit record | Pool / spaTI:OFFICE 63' x 44' SPACE, METAL STUDS W/ GYP BD, SEE LETTERS FOR ACCESSIBLITY AT ALL TIMES TO ACCESSIBILE RESTROOMS IN TENANT SPACE ON 2ND FLOOR AND 2ND EXIT THROUGH ADJACENT TENANT SPACE. ( INSPECTOR VERIFY THIS ACCESSIBILITY TO 2ND EXIT AND TO ACCESSIBLE RESTROOMS ON 2ND FLOOR IN THE FIELD PRIOR TO FINAL INSPECTION) | C of o | |
| 2005-08-02 | T05AN00839City permit record | ADDRNEW | Issued | |
| 2005-08-02finaled | T05CM04022City permit record | COMBOTI:OFFICE | C of o | |
| 2005-03-28finaled | T05OT00635City permit record | SIGNSIGN: 8732 BOURN PARTNERS | Final | |
| 2002-04-15finaled | T02OT00577City permit record | SIGNSIGN:3877 | Final | |
| 2001-03-27finaled | T01EL00714City permit record | ELECTSIGN:ELECTRIC:2234 | Final | |
| 2000-12-27 | T00AN01040City permit record | ADDRNEW | Issued | |
| 2000-12-14expired 2001-06-12 | T00BU03635City permit record | TENTSTENT:FOR OPEN HOUSE | Closed | |
| 2000-11-13expired 2001-05-30 | T00BU03350City permit record | BUILDCARPORT:TD#14-60-85 | Expired | |
| 1999-09-14finaled | T99BU02541City permit record | SPKLRFIRE SPKR:RELOCATE 9 ADD 6 | Final | |
| 1999-08-20finaled | T99CM04023City permit record | COMBOTI:OFFICE | C of o | |
| 1997-04-14finaled | T97CM00829City permit record | COMBOTI:REMODEL OFFICE ON 2ND OF 4 STORIES METAL STUDS WITH GYP. BD. | C of o |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (8)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2011-02-09finaled | T11FR00409Code enforcement case | Code enforcement case | Complete |
| 2010-05-13finaled | T10FR00968Code enforcement case | Code enforcement case | Complete |
| 2009-02-03finaled | T09FR00464Code enforcement case | Code enforcement case | Complete |
| 2008-07-09finaled | T08FR01828Code enforcement case | Code enforcement case | Complete |
| 2006-05-31finaled | T06FR01669Code enforcement case | Code enforcement case | Complete |
| 2006-04-10finaled | T06FR00710Code enforcement case | Code enforcement case | Complete |
| 2006-04-04 | T06FR00655Code enforcement case | Code enforcement case | Field |
| 2005-02-07finaled | T05FR00205Code enforcement case | Code enforcement case | Complete |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 126070730 — 37 permits on file from 1997 to 2019 (10 combo, 9 spklr, 4 build, 3 sign) and 8 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).