3902 E Speedway Bl

Built 1995 — 1990s commercial stock · 28 permits on record; no permitted panel/service or HVAC work among them

Parcel
12605001C
Built
1995 (county record)
Jurisdiction
Tucson
Zoning
C-1
Assessor use
Convenience Store With Fuel Dispensing
Parcel size
0.90 acres
Building area
3,217 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 3902 E Speedway Bl, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2020 (6 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T20FC00227 — CO2 gas detection alarm
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2021. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2015-01-16$39,750,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2025-05-20 (TR-ROW-0525-00698) — The contractor will be installing cameras onto light poles for the Tucson Police Department. Shadow Truck less than an hour per location. 60 day Permit..

Permit history (28)

Permit history for this parcel — 8 of 28 records
DateRecordWhatStatusValue
2025-05-20finaledTR-ROW-0525-00698City permit recordRight-of-Way (ROW)The contractor will be installing cameras onto light poles for the Tucson Police Department. Shadow Truck less than an hour per location. 60 day Permit.Complete
2024-06-24finaledTR-ROW-0624-00723City permit recordRight-of-Way (ROW)COT annual palm tree trimming -Complete
2023-07-05finaledTR-ROW-0723-00928City permit recordRight-of-Way (ROW)Annual Palm Tree TrimmingComplete
2021-10-13finaledT21RW04672City permit recordPool / spaINSTALL LETTERS ON WALL BEHIND SIDEWALK. BUS STOP IN THE AREA, CONTACT SUN TRAN DISPATCH, AT 520-206-8934 AND/OR BEA PAULUS AT 520-206-8826 AT LEAST 48-BUSINESS HOURS PRIOR TO START OF WORK FOR COORDINATION. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. 1. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. 2. MAINTAIN PEDESTRIAN ACCESS 3. IN THE EVENT THAT WEEKEND OR AFTER-HOURS WORK IS INTENDED, CONTACT COT INSPECTION STAFF. DAN ROBERTSON- 520-400-6722 OR TOM ADKINS- 520-400-3813Final
2020-04-06finaledT20FC00227City permit recordFIRECONSCO2 gas detection alarmFinal
2019-09-12T19CM06655City permit recordCommercial BuildingE - NEW KITCHEN EQUIPMENT TO MADE TO COOK AREAExpired
2019-06-07finaledT19OT00507City permit recordSIGNrebrand of six signsFinal
2018-11-20finaledT18RW05177City permit recordROWUtility Repair/ Replacing Type A Pole and foundation in south median of Speedway and Alvernon intersection. COT JOC Emergency RepairFinal
Show 20 older records
Permit history for this parcel — remaining 20 records
DateRecordWhatStatusValue
2018-04-10finaledT18FO00295City permit recordFIREOPERREPLACE SPILL BUCKETSFinal
2018-03-20T18FO00237City permit recordFIREOPERGIANT #6646 - CO2 Beverage SystemVoid
2018-01-25finaledT18CM00657City permit recordCOMBOREPLACE HEATPUMP AND CURB ADAPTERFinal
2017-12-08finaledT17FO01042City permit recordFIREOPERCO2 - GIANT 6646Final
2017-12-08finaledT17FO01059City permit recordFIREOPERFLAM/COMB - GIANT 6646Final
2017-10-12finaledT17RW04526City permit recordROWCITY OF TUCSON MEDIAN PALM CAREFinal
2016-11-16finaledT16FC00233City permit recordFIRECONSExcavate to allow re-lining of 2 tanksFinal
2015-02-05finaledT15BU00131City permit recordTANKSUNDER GROUND STORAGE TANK CLOSUREFinal
2014-12-09finaledT14OT01541City permit recordFence / wallC OF C ON DF / 1- ILLUM WALL SIGNFinal
2013-12-12finaledT13CFW0107City permit recordFIREWRKS*APPROVED FIREWORKS PERMIT FOR SALE AND STORAGE* CONTACT TFD 791-4502 FOR THE REQUIRED INSPECTIONSFinal
2012-11-23finaledT12CFW0110City permit recordFIREWRKSAPPROVED FIREWORKS PERMIT FOR SALE AND STORAGE:CONTACT TFD 791-4502 FOR THE REQUIRED INSPECTIONFinal
2009-07-28finaledT09OT01566City permit recordSIGNSIGN 16959Final
2009-07-20expired 2015-02-05T09EL01685City permit recordELECTINSTALL:LIGHT BAR ON GAS CANPOYExpired
2008-05-20finaledT08CM01649City permit recordCOMBONEW: STEEL CAGE FOR EXCHANGE/SALE OF PROPANE CYLINDERSFinal
2006-04-11finaledT06EL00677City permit recordELECTELEC: RELOCATE TO SALES COUNTERFinal
2004-08-27finaledT04OT01727City permit recordSIGNSIGN:7685Final
2004-02-26T04AN00171City permit recordADDRNEWIssued
2004-02-26finaledT04EL00400City permit recordELECTREPLACE:FUEL DISPENSERSFinal
2003-12-15expired 2004-09-21T03OT02226City permit recordSIGNSIGN:#6469Closed
1997-10-28expired 2008-12-08T97CM03468City permit recordCOMBOTI:STOREClosed

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (8)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 8 records
DateRecordWhatStatus
2025-09-22CE-VIO0925-04174Code enforcement caseCode enforcement caseClosed - resolved
2024-08-06CE-VIO0824-03084Code enforcement caseVegetationClosed - resolved
2016-04-07T16DV02216Code enforcement caseVegetationComplian
2012-06-15T12DV04998Code enforcement caseRefuseComplian
2012-04-11T12DV02869Code enforcement caseRefuseComplian
2010-10-12T10DV07048Code enforcement caseCode enforcement caseReferred
2007-02-27T07DV01887Code enforcement caseVegetationComplian
2003-03-27T03VL00369Code enforcement caseSignComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 12605001C — 28 permits on file from 1997 to 2025 (4 sign, 4 fireoper, 3 right-of-way (row), 3 combo) and 8 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.