Electrical permit history — 4668 E Speedway Bl

4668 E Speedway Bl, Tucson — built 1960, with 54 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

4668 E Speedway Bl

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1960 — 1960s commercial stock · last permitted panel/service work 2021 (finaled) · HVAC 2012 (finaled) · 1 open code case

Is it time to upgrade?

  • Electrical service & distributionFinaled permit foundLast permitted 2021 (5 years ago). Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T21CM05909 — Replace electrical service panel up to 200amp, like for like.
  • Heating, cooling & mechanicalGetting onLast permitted 2012 (14 years ago). Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T12CM05729 — REPLACE 5 TON ROOF MOUNT AC
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    A finaled 2021 panel/service permit is on record for this parcel, which makes it unlikely the original 60–100 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth looking at

    There is an open code enforcement case on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2025. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Worth confirming

    There is an electrical reconnect permit from 2002. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Routine

    A trade permit was pulled in 2021. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 6,129 sq ft (assessor’s building area ÷ recorded stories — approximate)
Usable for solar, planning estimate
≈ 4,300 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 45 kW — roughly 110 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 74,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$6,000–$9,500 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “El Con Mall - Reid Park Area”, is about 1 mile away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
126020010
Year constructed
1960 (assessor record)
Permitting authority
Tucson
Zoning
C-2
Property type
Store Front Commercial Bldg
Building area
6,129 sq ft
Service on record
City records show the 2021 permit was finalized; the permit description states “Replace electrical service panel up to 200amp, like for like.”.

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 54 building permits for this parcel dated between 1999 and 2026. By category the work is permanent sign (20), trade permit (13), addition / alteration (7) and annual portable sign compliance (6). 25 of them carry a final inspection; the other 29 were issued, expired or are still open, which is not the same as work completed. There are 16 code-enforcement cases recorded against the parcel, 1 of which is open. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 126020010. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All commercial property · Commercial property in 85712 · Commercial & industrial reports · Homes in 85712 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on E SPEEDWAY BL hold 4,858 City permits on record, 628 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (70 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026TS-TMP-0626-00011Temporary Sign ComplianceIssued
2026TS-TMP-0526-00010Temporary Sign ComplianceComplete
2026TS-TMP-0426-00007Temporary Sign ComplianceIssued
2026CE-VIO0426-01630Code enforcement caseClosed - Resolved
2026CE-VIO0426-01629Work without permitActive
2026TC-COM-0226-00266Commercial Addition/Alteration PermitWithdrawn
2025TD-DEV-0725-00189Development PackageIssued
2025TC-COM-0525-00911Commercial Addition/Alteration PermitInspections Complete
2025TC-COM-0625-01080Commercial Addition/Alteration PermitExpired
2025CE-VIO0525-01988Code enforcement caseClosed - Resolved
2024TC-COM-0524-01033Commercial Trade PermitIssued
2024TC-COM-0524-01037Commercial Trade PermitIssued
2024TC-COM-0524-00907Commercial Trade PermitIssued
2023TC-DMO-1123-00234Commercial Demolition PermitWithdrawn
2023TD-DEV-1023-00416Development PackageWithdrawn
2023TP-PRE-0523-00225Pre-Application ConferenceComplete
2022T22DV00415PROP MAINT MULTIPLE TYPESCOMPLIAN
2021T21DV06008HOMELESS CAMPSNOVERIFY
2021T21CM05909Commercial Trade PermitComplete
2021T21CM05261Commercial Trade PermitExpired
2021T21OT00280Permanent Sign PermitComplete
2020T20CM04074Commercial Trade PermitExpired
2020T20DV01898SIGN VIOLATIONCOMPLIAN
2019T19OT01177Permanent Sign PermitExpired
2019T18OT01177Permanent Sign PermitExpired
2018T18SA00514Zoning ComplianceApproved
2016T16OT01430Permanent Sign PermitWithdrawn
2016T16OT01346Annual Portable Sign ComplianceCanceled
2016T16OT01084Annual Portable Sign ComplianceCanceled
2016T16OT00657Annual Portable Sign ComplianceCanceled
2016T16OT00260Annual Portable Sign ComplianceCanceled
2015T15OT01581Annual Portable Sign ComplianceCanceled
2015T15OT01191Annual Portable Sign ComplianceCanceled
2015T15DV04998GRAFFITINOVERIFY
2015T15DV03512SIGN VIOLATIONCOMPLIAN
2015T15DV02719SIGN VIOLATIONNOVERIFY
2015T15DV00372SIGN VIOLATIONCOMPLIAN
2013T13DV04682GRAFFITICOMPLIAN
2013T13OT00060Permanent Sign PermitCanceled
2012T12DV11224SIGN VIOLATIONCOMPLIAN
2012T12CM06530Commercial Addition/Alteration PermitWithdrawn
2012T12CM05729Commercial Trade PermitComplete
2012T12DV07177WORK WITHOUT PERMITS-COMMERCLCOMPLIAN
2011T11DV07943SIGN VIOLATIONCOMPLIAN
2011T11CM02281Commercial Addition/Alteration PermitWithdrawn
2011T11OT00202Permanent Sign PermitCanceled
2011T11DV00069SIGN VIOLATIONCOMPLIAN
2010T10DV03241SIGN VIOLATIONNOVERIFY
2008T07OT02920Permanent Sign PermitComplete
2007T07OT01043Permanent Sign PermitComplete
2007T07OT00967Permanent Sign PermitComplete
2007T07DV03424Permanent Sign PermitComplete
2006T06PL02271Commercial Trade PermitComplete
2006T06OT01737Permanent Sign PermitComplete
2006T06ME00344Residential Trade PermitCanceled
2006T06VL00575Permanent Sign PermitComplete
2006T06CM02962Commercial Trade PermitWithdrawn
2005T05ME00996Residential Trade PermitComplete
2005T05OT01539Permanent Sign PermitComplete
2005T05OT01552Permanent Sign PermitComplete
2005T05OT00937Permanent Sign PermitComplete
2004T04BU02785Commercial Addition/Alteration PermitComplete
2004T04BU02103Commercial Addition/Alteration PermitCanceled
2004T04OT01223Permanent Sign PermitComplete
2004T04OT00283Permanent Sign PermitComplete
2003T03OT00827Permanent Sign PermitComplete
2002T02EL02160Residential Trade PermitComplete
2001T01EL00165Commercial Trade PermitComplete
1999T99VL02151Permanent Sign PermitComplete
1999T99VL01317Permanent Sign PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 126020010 — 54 City permits on file from 1999 to 2026 and 16 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.