Electrical permit history — 3382 E Speedway Bl
3382 E Speedway Bl, Tucson — built 1950, with 80 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
3382 E Speedway Bl
Built 1950 — 1950s commercial stock · last permitted panel/service work 2024 (finaled); a newer 2026 permit is issued
Permanent link: Electrical permit history for 3382 E Speedway Bl (aztucsonelectricalsolutions.com/property/12512080a/3382-e-speedway-bl-tucson-az-85716) · Public records last checked 2026-08-16
- Parcel
- 12512080A
- Built
- 1950 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-3
- Assessor use
- Neighborhood Shopping Center
- Parcel size
- 3.81 acres
- Building area
- 40,220 sq ft (assessor record)
- Sewer
- Connection on file (2012, 2024, 2025) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- City records show the 2024 permit was finalized; the permit description states “Like for like 800amp switch replacement. Site is occupied by Whole Foods.”.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionCurrentA newer 2026 permit for the same system is recorded as “Issued” — The work was permitted, but final completion is not confirmed. The permit description states “Replacing switchgear that is no longer up to code.”. Last permitted 2024 (2 years ago). City inspection record: COT - LCEL - Electrical Final approved 2024-12-18. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. TC-COM-1024-02002 — Like for like 800amp switch replacement. Site is occupied by Whole Foods.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 certificate of occupancy permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyCurrentA newer 2025 permit for the same system is recorded as “Inspections” — The work was permitted, but final completion is not confirmed. The permit description states “new canopy fire sprinklers”. Last permitted 2025 (1 year ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0225-00145 — New Fire Suppression Systems Install for Kitchen Hoods
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
A pool or spa was permitted in 2009. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.
Recorded sales (1)
| Date | Price | Type |
|---|---|---|
| 2022-03-09 | $10,100,000 | Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2026-08-11 (TC-COM-0826-01271) — Replacing switchgear that is no longer up to code..
Permit history (80)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-08-11expires 2027-08-14 | TC-COM-0826-01271City permit record | Commercial BuildingReplacing switchgear that is no longer up to code. | Issued | |
| 2025-09-29finaled | TC-CFO-0925-00145City permit record | Certificate of Occupancy***TCO WITHDRAWN PER CUSTOMER REQUEST*** Tenant Improvement | Complete | |
| 2025-09-23expired 2026-04-26 | TS-PRM-0925-00391City permit record | Sign - PermanentLED Illuminated pan channel letters | Issued | |
| 2025-07-22finaled | TF-FOP-0725-00992City permit record | Fire OperationalPlaces of Assembly permit. TC-COM-0724-01416 | Complete | |
| 2025-07-14finaled | TF-FCP-0725-00568City permit record | Fire ConstructionADD MONITORING MODULES FOR DUCT/SMOKES & ANSUL HOODS TO EXISTING ES-50 FACP | Complete | |
| 2025-07-02 | TR-ROW-0725-00883City permit record | Right-of-Way (ROW)Removing and replacing the parking lot for the entire property. *** CLOSURE TO ENTRANCES OFF OF SPEEDWAY, CAMINO MIRAMONTE AND 1ST ST | Needs resubmittal | |
| 2025-06-04expired 2025-12-23 | TF-FCP-0625-00452City permit record | Fire Constructionnew canopy fire sprinklers | Inspections | |
| 2025-05-08expired 2025-11-12 | TS-PRM-0525-00193City permit record | Fence / wall(2) New illuminated wall signs | Issued |
72 older records are not shown here. — each links to its official file.
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (20)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2026-02-05closed 2026-04-03 | CE-VIO0226-00596Code enforcement case | Electrical | Closed - Resolved |
| 2017-02-13 | T17DV00628Code enforcement case | Code enforcement case | Complian |
| 2016-11-02 | T16DV07625Code enforcement case | Code enforcement case | Complian |
| 2011-11-03 | T11DV09002Code enforcement case | Vegetation | Complian |
| 2011-06-20 | T11DV04679Code enforcement case | Code enforcement case | Noverify |
| 2010-02-23 | T10DV00797Code enforcement case | Sign | Invalid |
| 2009-07-07finaled | T09FR02198Code enforcement case | Fire | Complete |
| 2009-06-24finaled | T09FR02039Code enforcement case | Fire | Complete |
Show 12 older records
| Date | Record | What | Status |
|---|---|---|---|
| 2009-06-23 | T09DV03596Code enforcement case | Electrical | Complian |
| 2008-06-25finaled | T08FR01699Code enforcement case | Code enforcement case | Complete |
| 2008-04-15finaled | T08FR00972Code enforcement case | Fire | Complete |
| 2008-04-08finaled | T08FR00856Code enforcement case | Fire | Complete |
| 2007-05-25finaled | T07FR01014Code enforcement case | Fire | Complete |
| 2007-04-13finaled | T07FR00716Code enforcement case | Code enforcement case | Complete |
| 2007-03-28 | T07FR00597Code enforcement case | Code enforcement case | Field |
| 2007-03-28finaled | T07FR00596Code enforcement case | Code enforcement case | Complete |
| 2007-03-28finaled | T07FR00595Code enforcement case | Code enforcement case | Complete |
| 2006-07-25 | T06VL00973Code enforcement case | Sign | Complian |
| 2005-04-27finaled | T05FR00539Code enforcement case | Code enforcement case | Complete |
| 2003-06-27 | T03VL00614Code enforcement case | Code enforcement case | Complian |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Send: the permanent link and the summary above, once. Watch: one email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list either way.
How this report was built
This is a reading of public records for parcel 12512080A — 80 permits on file from 1999 to 2026 (14 sign, 12 combo, 7 commercial building, 5 fire construction) and 20 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.