Electrical permit history — 3653 E 2nd St

3653 E 2nd St, Tucson — built 1978, with 46 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Multifamily property

3653 E 2nd St

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1978 — 1970s multifamily stock · 46 permits on record; no permitted panel/service or HVAC work among them

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2017 combo permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Nothing permitted on the service or distribution shows in the record we read, which for a building of this era leaves the original switchgear generation in play. Obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown — worth establishing what is actually installed before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2017 combo permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2025. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

Solar and energy potential

Roof footprint
≈ 12,787 sq ft (county building-footprint layer)
Usable for solar, planning estimate
≈ 9,000 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 100 kW — roughly 250 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 160,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$13,000–$21,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacity — mapped saturation areaThis property sits within about half a mile of “El Con Mall - Reid Park Area”, one of 11 areas TEP has mapped as saturated with distributed generation (customer solar) relative to circuit capacity. On a saturated circuit, new solar or battery systems can trigger supplemental utility review before interconnection is approved — and a large new load such as DC fast charging or process equipment is worth a capacity conversation with TEP before a site plan hardens. The boundary here is approximate, digitized from TEP’s map of the area (PDF, July 2020); TEP’s own interconnection screening is the authority, and circuit status can have changed since the maps were published.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
125110810
Year constructed
1978 (county record)
Permitting authority
Tucson
Zoning
R-3
Property type
Apartments 25 - 99 Units 2 Story
Sewer
Connection on file (1977) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 46 building permits for this parcel dated between 2007 and 2025. By category the work is commercial building (17), elect (14) and electrical reconnect (3). 26 of them carry a final inspection; the other 20 were issued, expired or are still open, which is not the same as work completed. There are 29 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 125110810. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All multifamily property · Commercial property in 85716 · Commercial & industrial reports · Homes in 85716 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

Complete permit record (75 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2025TR-UTL-0325-00468Right-of-Way (ROW) - UtilityComplete
2025SP-NRP-0325-00135SimpleComplete
2025SP-NRP-0125-00001SimpleComplete
2024TC-COM-0824-01494Commercial BuildingApproved - awaiting cust
2024TC-COM-0824-01495Commercial BuildingApproved - awaiting cust
2024TC-COM-0824-01496Commercial BuildingApproved - awaiting cust
2024TC-COM-0824-01497Commercial BuildingExpired
2024TC-COM-0824-01498Commercial BuildingApproved - awaiting cust
2024TC-COM-0824-01499Commercial BuildingApproved - awaiting cust
2024TC-COM-0824-01500Commercial BuildingApproved - awaiting cust
2024TC-COM-0824-01501Commercial BuildingApproved - awaiting cust
2024TC-COM-0824-01502Commercial BuildingApproved - awaiting cust
2024TC-COM-0824-01503Commercial BuildingApproved - awaiting cust
2024TC-COM-0824-01504Commercial BuildingApproved - awaiting cust
2024TC-COM-0824-01505Commercial BuildingApproved - awaiting cust
2024TC-COM-0824-01506Commercial BuildingApproved - awaiting cust
2024TC-COM-0824-01507Commercial BuildingApproved - awaiting cust
2024TC-COM-0824-01508Commercial BuildingVoid
2024TC-COM-0724-01376Commercial BuildingApproved - awaiting cust
2023CE-VIO0823-04901Code enforcement caseClosed - resolved
2023CE-VIO0623-04306Code enforcement caseClosed - unfounded
2023CE-VIO0523-03251Code enforcement caseClosed - unfounded
2023CE-VIO0323-02314Code enforcement caseClosed - unfounded
2023CE-VIO0323-02311VegetationClosed - resolved
2023CE-VIO0223-01905Code enforcement caseClosed - resolved
2023TZ-CMP-0123-00041Zoning Verification LetterComplete
2022CE-VIO1222-01065RefuseClosed - unfounded
2022CE-VIO1222-00878Code enforcement caseReferred
2022T22DV04489RefuseNoverify
2019T19DV04595Code enforcement caseComplian
2019T19DV01947ElectricalNoverify
2018T18DV07894Code enforcement caseComplian
2018T18CM08590Commercial BuildingCanceled
2018T18DV05188Code enforcement caseComplian
2017T17CM09507COMBOFinal
2017T17CM09508COMBOFinal
2017T17CM08917COMBOWithdrwn
2017T17CM07761COMBOFinal
2017T17DV05189FireComplian
2017T17DV04024Code enforcement caseComplian
2015T15CM01374COMBOL of c
2015T15DV00158Code enforcement caseCancel
2015T15DV00164Code enforcement caseComplian
2014T14DV10131FireComplian
2014T14DV09511Code enforcement caseComplian
2012T12DV06674RefuseNoverify
2012T12CM03247COMBOFinal
2012T12CM03076COMBOExpired
2012T12CM02394COMBOFinal
2012T12CM02133COMBOFinal
2012T12CM02059COMBOFinal
2011T11EL03279ELECTFinal
2011T11EL03020ELECTFinal
2011T11EL02731ELECTFinal
2011T11EL02732ELECTFinal
2011T11EL02698ELECTFinal
2011T11EL02659ELECTFinal
2011T11EL02647ELECTFinal
2011T11EL02482ELECTFinal
2011T11EL02084ELECTFinal
2011T11EL01961ELECTFinal
2011T11EL01655ELECTFinal
2010T10DV03917Code enforcement caseComplian
2010T10EL00444ELECTFinal
2010T10DV00693Code enforcement caseComplian
2009T09CM01165COMBOExpired
2008T08DV09907Code enforcement caseComplian
2008T08EL00037ELECTFinal
2007T07DV09170Code enforcement caseComplian
2007T07DV07617ElectricalNoverify
2007T07DV07349Code enforcement caseComplian
2007T07EL00867ELECTFinal
2007T07FR00627Code enforcement caseComplete
2007T07FR00453Code enforcement caseComplete
2007T07DV00711Code enforcement caseComplian

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 125110810 — 46 permits on file from 2007 to 2025 (17 commercial building, 14 elect, 9 combo, 3 electrical reconnect) and 29 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-22; the permit record is refreshed on a rolling cycle (at least every 45 days), and the assessor’s building file when the county publishes a new roll. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.