Electrical permit history — 3421 E Broadway Bl

3421 E Broadway Bl, Tucson — built 2006, with 18 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

3421 E Broadway Bl

Built 2006 — 2000s commercial stock · 18 permits on record; no permitted panel/service or HVAC work among them

Parcel
125101410
Built
2006 (assessor record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Power Center
Parcel size
1.20 acres
Building area
8,190 sq ft (assessor record)
Sewer
Connection on file (2013) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 3421 E Broadway Bl, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2019 fence / wall permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2019 fence / wall permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentA newer 2020 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “Fire Alarm & Detection Systems - Replace the existing fire riser monitor, install a cellular transmitter, connect the CO2 detection system.; Fire Alarm Systems - New Sq Ft: 5000”. Last permitted 2020 (6 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T20FC00014 — RUBIOS - CO2 GAS DETECTION SYSTEM
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2023-01-03 (TC-COM-0123-00397) — VOID - Duplicate of T22CM01111 - 9814 - Drive thru menu relocation.

Permit history (18)

Permit history for this parcel — 8 of 18 records
DateRecordWhatStatusValue
2023-01-03expired 2023-07-02TC-COM-0123-00397City permit recordCommercial BuildingVOID - Duplicate of T22CM01111 - 9814 - Drive thru menu relocationVoid
2022-12-15TC-COM-1222-00305City permit recordCommercial BuildingVOID=wrong permit type STARBUCKS 9814 - DRIVE THRU MENU RELOCATIONVoid
2022-02-14finaledT22CM01111City permit recordCommercial BuildingRelocation of menu boardSIGN CONTRACTOR: MARANA SIGN SERVICESComplete
2020-06-09expired 2021-07-11T20FC00384City permit recordFire ConstructionFire Alarm & Detection Systems - Replace the existing fire riser monitor, install a cellular transmitter, connect the CO2 detection system.; Fire Alarm Systems - New Sq Ft: 5000Expired
2020-01-13finaledT20FC00014City permit recordFIRECONSRUBIOS - CO2 GAS DETECTION SYSTEMFinal
2020-01-13finaledT20FO00027City permit recordFIREOPERRUBIOS - CO2 SYSTEMFinal
2019-10-07T19FO00817City permit recordFIREOPEREXISTING UNITWithdrwn
2019-07-24finaledT19FC00573City permit recordFence / wallModify exisitng fire sprinkler system to accomodate changes to walls and ceilings of tenant.Final
Show 10 older records
Permit history for this parcel — remaining 10 records
DateRecordWhatStatusValue
2019-07-17expired 2020-04-25T19OT00660City permit recordSIGN90 DAY BANNER EXP ON OCT 23 2019Closed
2019-07-16finaledT19FO00554City permit recordFIREOPERRubios Mexican Grill #211 - OCC: 98Final
2019-06-07finaledT19OT00512City permit recordFence / wall2-ILLUM WALL SIGNS + C of C.Final
2019-04-26finaledT19CM02985City permit recordCOMBOTI: VERIZONL of c
2019-01-04finaledT19RW00045City permit recordROWStart Point: from the COX ped on the West side of 3421 E Broadway begin 275' bore/trench head East. Place COX ped Continue 30' trench/bore heading North to out of ROWFinal
2018-02-23expired 2018-04-28T18RW00929City permit recordROWStarting at Cox ped North of Broadway trench/bore going East 305' continue going North 10' to out of ROWExpired
2014-12-09finaledT14OT01548City permit recordSIGNRE-BRANDING OF SITEFinal
2014-02-19finaledT14BU00205City permit recordSPKLRFIRE SPRINKLERFinal
2014-01-17finaledT14OT00078City permit recordFence / wall2- ILLUM WALL SIGNS / 1- UCFinal
2013-12-18finaledT13CM07639City permit recordCOMBORETAILC of o

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (1)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 1 of 1 records
DateRecordWhatStatus
2025-10-23CE-VIO1025-04667Code enforcement caseCode enforcement caseClosed - unfounded

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 125101410 — 18 permits on file from 2013 to 2023 (3 commercial building, 3 fireoper, 3 fence / wall, 2 sign) and 1 code enforcement case — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.