Electrical permit history — 3605 E Broadway Bl

3605 E Broadway Bl, Tucson — built 2003, with 20 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

3605 E Broadway Bl

Built 2003 — 2000s commercial stock · 20 permits on record; no permitted panel/service or HVAC work among them

Parcel
125101380
Built
2003 (assessor record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Power Center - Restaurant
Parcel size
1.25 acres
Building area
4,912 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 3605 E Broadway Bl, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentA newer 2026 permit for the same system is recorded as “Issued” — The work was permitted, but final completion is not confirmed. The permit description states “Sprinkler Monitoring System”. Last permitted 2021 (5 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T21FC00582 — eplace existing cellular/dialer connected to existing FACP with new.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Food service carries heavy, cycling kitchen loads and exhaust interlocks. Capacity and existing panel space are the first things to verify on any remodel.

Most recent permit on record for this parcel: 2026-06-25 (TF-FCP-0626-00419) — Sprinkler Monitoring System.

Permit history (20)

Permit history for this parcel — 8 of 20 records
DateRecordWhatStatusValue
2026-06-25expires 2027-01-14TF-FCP-0626-00419City permit recordFire ConstructionSprinkler Monitoring SystemIssued
2026-06-25expires 2027-01-20TF-FCP-0626-00420City permit recordFire Construction53 sprinkler restaurant TIIssued
2026-06-25TF-FOP-0626-00896City permit recordFire OperationalFire General Permit for TF-FCP-0226-00114 CO2 Detection System PermitFees paid
2026-06-16expires 2026-12-29TF-FCP-0626-00400City permit recordFire ConstructionFire Suppression system plansIssued
2026-02-20expires 2027-01-14TF-FCP-0226-00114City permit recordFire ConstructionCO2 Gas Detection and Alarm System OnlyIssued
2026-02-20expires 2026-12-07TS-PRM-0226-00068City permit recordFence / wallInstall four (4) int. Illum. channel wall signs 5’-0” x11’-9”; one (1) int. Illum. logo sign 5’-0” x5’-0; two (2) int. illum. directional signs 1’-2” x 2’-7”, 3’-0” (OAH); one (1) menu board; two (2) clearance armsIssued
2025-01-24finaledTR-UTL-0125-00148City permit recordRight-of-Way (ROW) - Utilitymanhole access at Broadway & Randolph way MH ACCESS PERMIT REQUIRED FOR SPLICING AT MH 7646AComplete
2025-01-10expires 2027-06-22TC-COM-0125-00069City permit recordCommercial BuildingNEW AWNINGS NEW ILLUM. CANOPIESIssued
Show 12 older records
Permit history for this parcel — remaining 12 records
DateRecordWhatStatusValue
2025-01-10expires 2027-06-22TC-COM-0125-00070City permit recordCommercial BuildingDRIVE-THRU CLEARANCE ARMIssued
2024-12-20TS-PRM-1224-00568City permit recordSign - Permanent1. TC-COM-0823-02094 not aprov or paid /2. needs a COTBL . NEW 5’-0” ILLUM. “CHICK-FIL-A” ICON LOGO CABINET . NEW D/F ILLUM. DIRECTIONAL SIGN . DRIVE-THRU MENU BOARD . DRIVE-THRU CLEARANCE ARMExpired
2023-11-17TF-FCP-1123-01326City permit recordFire ConstructionWITHDRAWN - Contractor never resubmitted permit (needed to provide COT Business License & AZROC. Also needed to add installing contractor to plans) - We will be relocating/upgrading existing CO2 tank and monitoring systemsWithdrawn
2023-08-28expires 2027-08-11TC-COM-0823-02094City permit recordAddition / alterationRemodel project will include a new order point canopy, order meal delivery canopy, a reworking of the drive-thru including an additional lane and bypass lane, 400 sf building expansion, new trash enclosure, relocation of light poles, relocation of water meter, and a new parking lot layout.Inspections
2023-01-11expires 2029-07-30TD-DEV-0123-00102City permit recordDevelopment PackageRev 1 - started 06.15.2026, updates to canopies, drive through, landscape, etc ** Remodel of existing Chick-fil-a siteIssued
2021-09-10expired 2022-07-23DP21-0242City permit recordDevelopment PackageWITHDRAWN - SITE - Chick-Fil-A, store# 2224. Install shade canopy over drive-thru window.Withdrawn
2021-08-11expired 2022-07-27T21CM06502City permit recordCommercial BuildingInstall canopy over existing drive thru for the protection of employees.Expired
2021-07-22finaledT21FC00582City permit recordFIRECONSeplace existing cellular/dialer connected to existing FACP with new.Final
2019-05-02T19CM03138City permit recordCommercial BuildingCANOPY FOR DRIVE THRUCanceled
2018-04-18finaledT18RW01743City permit recordROWMANHOLE ACCESS FORMH 9330,9113,9093 AND 10272Final
2017-05-22finaledT17FC00425City permit recordFIRECONSRE-ALLIGNING NOZZLES OVER APPLIANCES FOR PROPER COVERAGE.Final
2014-03-17finaledT14CM01506City permit recordCOMBOREPL 40 GAL WATER HEATER (APA_Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 125101380 — 20 permits on file from 2014 to 2026 (5 fire construction, 4 commercial building, 2 development package, 2 firecons) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.