Electrical permit history — 2855 E Broadway Bl

2855 E Broadway Bl, Tucson — built 1973, with 11 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

2855 E Broadway Bl

Built 1973 — 1970s commercial stock · HVAC 2019 (finaled)

Parcel
125091430
Built
1973 (county record)
Jurisdiction
Tucson
Zoning
C-1
Assessor use
Store Front Commercial Bldg
Parcel size
0.22 acres
Building area
2,346 sq ft (assessor record)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Sunshine Mile Historic District — National Register district — Contributing (City of Tucson)

See the property

County aerial photograph centered on 2855 E Broadway Bl, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalCurrentLast permitted 2019 (7 years ago). City inspection record: MECHANICAL - FINAL approved 2019-05-21. Contractor of record: ORO VALLEY HEATING & COOLING. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T19CM03387 — RETROFIT 2 - 5 TON GAS PACKAGES
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2014. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

Most recent permit on record for this parcel: 2023-12-29 (TC-COM-1223-02960) — Tenant Improvement to include remodel of existing bathrooms/space.

Permit history (11)

Permit history for this parcel — 8 of 11 records
DateRecordWhatStatusValue
2023-12-29expired 2024-06-26TC-COM-1223-02960City permit recordPool / spaTenant Improvement to include remodel of existing bathrooms/spaceApproved
2023-02-24expired 2023-08-23TC-COM-0223-00716City permit recordCommercial BuildingAdd ADA bathroomWithdrawn
2020-06-02finaledT20RW03122City permit recordROWWAM # 2007079 emergency water valve replacement, in the intersection of e broadway blvd and n stewart ave on the south side of broadway in the road.Final
2019-05-13finaledT19CM03387City permit recordCOMBORETROFIT 2 - 5 TON GAS PACKAGESFinal
2019-04-11T19EL00114City permit recordELECTRETROFIT TWO 5 TON 15 SEER GAS PACKAGES UNITSWithdrwn
2019-04-11T19EL00115City permit recordELECTRETROFIT TWO 5 TON 15 SEER GAS PACKAGES UNITSWithdrwn
2018-12-07finaledT18CM09574City permit recordCOMBOREPL YARD WATER LINEFinal
2018-02-26finaledT18RW00950City permit recordROW(2) 5x5 AND 4' IN DIRT IN FRONT ON STEWART AVE TO REPAIR/REPLACE GAS LINEFinal
Show 3 older records
Permit history for this parcel — remaining 3 records
DateRecordWhatStatusValue
2014-09-22finaledT14CM06270City permit recordCOMBORECONNECT ELECTRIC; RETAILFinal
2013-04-11T13OT00440City permit recordFence / wallPermit (5) existing painted wall signs (barber poles)Withdrwn
2013-01-29T13CM00526City permit recordCOMBOTI: HAIR SALONWithdrwn

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (9)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 9 records
DateRecordWhatStatus
2025-12-15CE-VIO1225-05357Code enforcement caseCode enforcement caseClosed - resolved
2020-02-27T20DV01481Code enforcement caseVegetationNoverify
2018-12-03T18DV07808Code enforcement caseGraffitiComplian
2014-08-05T14DV05760Code enforcement caseVegetationComplian
2013-08-06T13DV05728Code enforcement caseVegetationComplian
2013-01-25T13DV00568Code enforcement caseSignComplian
2012-08-13T12DV06952Code enforcement caseCode enforcement caseCourtncm
2008-03-17finaledT08FR00715Code enforcement caseFireComplete
Show 1 older record
Code enforcement history for this parcel — remaining 1 records
DateRecordWhatStatus
2006-12-14finaledT06FR02887Code enforcement caseCode enforcement caseComplete

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 125091430 — 11 permits on file from 2013 to 2023 (4 combo, 2 row, 2 elect, 1 pool / spa) and 9 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.