Built 1953 — 1950s commercial stock · last permitted panel/service work 2015 (finaled)
Permanent link: Electrical permit history for 2245 E Broadway Bl (aztucsonelectricalsolutions.com/property/12501035a/2245-e-broadway-bl-tucson-az-85719) · Public records last checked 2026-09-22
Is it time to upgrade?
- Electrical service & distributionFinaled permit foundLast permitted 2015 (11 years ago). The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T15CM06259 — 200 AMP UPGRADE
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2013 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check
A finaled 2015 panel/service permit is on record for this parcel, which makes it unlikely the original 60–100 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
There is an electrical reconnect permit from 2019. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.
- Routine
A trade permit was pulled in 2015. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.
Solar and energy potential
- Roof footprint
- ≈ 15,396 sq ft (assessor’s building area ÷ recorded stories — approximate)
- Usable for solar, planning estimate
- ≈ 10,800 sq ft (~70% after setbacks, rooftop equipment and access paths)
- Array that could fit
- on the order of 120 kW — roughly 300 panels (low-tilt ballasted rows, 400 W class modules)
- Estimated annual production
- ≈ 200,000 kWh (PVWatts, Tucson sun, low-tilt south)
- Energy-charge offset at TEP commercial rates
- $16,000–$26,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)
Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.
TEP grid capacity — mapped saturation areaThis property sits within about half a mile of “Aviation Pkwy and Kino Pkwy”, one of 11 areas TEP has mapped as saturated with distributed generation (customer solar) relative to circuit capacity. On a saturated circuit, new solar or battery systems can trigger supplemental utility review before interconnection is approved — and a large new load such as DC fast charging or process equipment is worth a capacity conversation with TEP before a site plan hardens. The boundary here is approximate, digitized from TEP’s map of the area (PDF, July 2020); TEP’s own interconnection screening is the authority, and circuit status can have changed since the maps were published.
Get a commercial solar & switchgear analysis
See the property
Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.
Flood and drainage
The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.
- FEMA: we did not read the federal flood map for this snapshot, so no zone is shown here. That is a gap in this page, not a statement about the property. Check FEMA’s flood map for this address ↗
- Local floodplain (the City of Tucson): local floodplain mapping is not reproduced here. A property can sit outside FEMA’s zone and still be inside a locally regulated floodplain, floodway, sheet-flooding area or erosion hazard setback, so check the authority’s own map before planning work. Pima County RFCD flood hazard map for parcel 12501035A ↗ · the City of Tucson ↗
The record behind this read
- Parcel
- 12501035A
- Year constructed
- 1953 (assessor record)
- Permitting authority
- Tucson
- Zoning
- C-1
- Property type
- Municipal Commercial Property
- Building area
- 15,396 sq ft
- Service on record
- City records show the 2015 permit was finalized; the permit description states “200 AMP UPGRADE ” — an increase in capacity as described, not a confirmed installed rating.
The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.
The most recent permitted work on this parcel was in 2019. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.
What this means for work here
Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.
The most recent permitted work on this parcel was in 2019. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.
What that reading rests on. The issuing offices hold 50 building permits for this parcel dated between 1997 and 2019. By category the work is trade permit (25), permanent sign (14), addition / alteration (8) and zoning examiner special exception. 26 of them carry a final inspection; the other 24 were issued, expired or are still open, which is not the same as work completed. There are 8 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.
Go straight to the records
Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.
City permit record (50): 2019 T19CM07168 · 2019 T19CM07167 · 2019 T19CM07169 · 2015 T15CM07050 · 2015 T15CM07047 · 2015 T15CM06259 · 2015 T15CM06258 · 2015 T15CM06260 · 2013 T13CM07452 · 2013 T13OT01092 · 2013 T13OT00950 · 2013 T13OT00916 · 2013 T13CM04976 · 2013 T13OT00558 · 2013 T13SE00003 · 2012 T12PRE0085 · 2011 T11OT01106 · 2009 T09EL02294 · 2008 T08OT00604 · 2008 T08OT01620 · 2008 T08OT01621 · 2008 T08EL00573 · 2008 T08EL00572 · 2008 T08EL00571 · 2008 T08OT00730 · 2008 T08OT00140 · 2007 T07OT00566 · 2007 T07EL01875 · 2007 T07OT02099 · 2007 T07OT00570 · and 20 older — search the parcel at the office below
Code enforcement cases (8): 2015 T15DV05228 · 2015 T15DV00583 · 2013 T13DV08043 · 2013 T13DV08047 · 2013 T13DV08046 · 2011 T11DV07004 · 2011 T11DV04397 · 2008 T08DV10089
Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 12501035A. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.
In the public record: All institutional and public property · Commercial property in 85719 · Commercial & industrial reports · Homes in 85719 · Permit data by neighborhood
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.
How this property compares nearby
Properties on E BROADWAY BL hold 1,450 City permits on record, 296 of them since 2022.
Computed from the same public records as this report — counts and years, not an appraisal.
Complete permit record (58 entries)
Every permit and case we hold for this parcel, newest first. Each number links to the official file.
| Year | Number | Type | Status |
|---|---|---|---|
| 2019 | T19CM07168 | Commercial Trade Permit | Canceled |
| 2019 | T19CM07167 | Commercial Trade Permit | Canceled |
| 2019 | T19CM07169 | Commercial Trade Permit | Complete |
| 2015 | T15CM07050 | Commercial Trade Permit | Withdrawn |
| 2015 | T15CM07047 | Commercial Trade Permit | Withdrawn |
| 2015 | T15CM06259 | Commercial Trade Permit | Complete |
| 2015 | T15CM06258 | Commercial Trade Permit | Complete |
| 2015 | T15CM06260 | Commercial Trade Permit | Complete |
| 2015 | T15DV05228 | SIGN VIOLATION | COMPLIAN |
| 2015 | T15DV00583 | GRAFFITI | COMPLIAN |
| 2013 | T13CM07452 | Commercial Trade Permit | Canceled |
| 2013 | T13DV08043 | SIGN VIOLATION | COMPLIAN |
| 2013 | T13DV08047 | SIGN VIOLATION | COMPLIAN |
| 2013 | T13DV08046 | SIGN VIOLATION | COMPLIAN |
| 2013 | T13OT01092 | Permanent Sign Permit | Complete |
| 2013 | T13OT00950 | Permanent Sign Permit | Canceled |
| 2013 | T13OT00916 | Commercial Addition/Alteration Permit | Complete |
| 2013 | T13CM04976 | Residential Trade Permit | Complete |
| 2013 | T13OT00558 | Permanent Sign Permit | Canceled |
| 2013 | T13SE00003 | Zoning Examiner Special Exception | Approved |
| 2012 | T12PRE0085 | Pre-Application Conference | Canceled |
| 2011 | T11DV07004 | MULTIPLE TYPES | COMPLIAN |
| 2011 | T11OT01106 | Permanent Sign Permit | Canceled |
| 2011 | T11DV04397 | SIGN VIOLATION | COMPLIAN |
| 2009 | T09EL02294 | Commercial Trade Permit | Complete |
| 2008 | T08DV10089 | WEEDS | COMPLIAN |
| 2008 | T08OT00604 | Commercial Addition/Alteration Permit | Complete |
| 2008 | T08OT01620 | Permanent Sign Permit | Canceled |
| 2008 | T08OT01621 | Annual Portable Sign Compliance | Complete |
| 2008 | T08EL00573 | Commercial Trade Permit | Canceled |
| 2008 | T08EL00572 | Commercial Trade Permit | Canceled |
| 2008 | T08EL00571 | Commercial Trade Permit | Canceled |
| 2008 | T08OT00730 | Permanent Sign Permit | Complete |
| 2008 | T08OT00140 | Permanent Sign Permit | Complete |
| 2007 | T07OT00566 | Commercial Addition/Alteration Permit | Complete |
| 2007 | T07EL01875 | Commercial Trade Permit | Complete |
| 2007 | T07OT02099 | Permanent Sign Permit | Complete |
| 2007 | T07OT00570 | Commercial Addition/Alteration Permit | Canceled |
| 2007 | T07OT00567 | Commercial Addition/Alteration Permit | Canceled |
| 2006 | T06OT03207 | Commercial Addition/Alteration Permit | Withdrawn |
| 2006 | T06OT02312 | Permanent Sign Permit | Complete |
| 2006 | T06OT02108 | Permanent Sign Permit | Complete |
| 2006 | T06EL01433 | Residential Trade Permit | Complete |
| 2006 | T06OT01923 | Permanent Sign Permit | Complete |
| 2006 | T06OT00896 | Permanent Sign Permit | Complete |
| 2005 | T05EL02337 | Commercial Trade Permit | Withdrawn |
| 2005 | T05OT01584 | Commercial Addition/Alteration Permit | Withdrawn |
| 2004 | T04OT02386 | Permanent Sign Permit | Complete |
| 2004 | T04OT01613 | Permanent Sign Permit | Withdrawn |
| 2002 | T02EL00623 | Commercial Trade Permit | Withdrawn |
| 2002 | T02EL00086 | Commercial Trade Permit | Canceled |
| 2000 | T00EL00711 | Commercial Trade Permit | Complete |
| 1999 | T99EL02359 | Commercial Trade Permit | Withdrawn |
| 1999 | T99EL01632 | Commercial Trade Permit | Complete |
| 1999 | T99PL00175 | Commercial Trade Permit | Complete |
| 1999 | T99OT00012 | Commercial Addition/Alteration Permit | Complete |
| 1998 | T98EL01586 | Commercial Trade Permit | Canceled |
| 1997 | T97EL01058 | Commercial Trade Permit | Complete |
prints this report — permits, comparisons and sources — as a clean document
How this report was built
This is a reading of public records for parcel 12501035A — 50 City permits on file from 1997 to 2019 and 8 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.
The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.