Electrical permit history — 998 S Cherry Av
998 S Cherry Av, Tucson — built 1982, with 20 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
998 S Cherry Av
Built 1982 — 1980s commercial stock · 20 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 998 S Cherry Av (aztucsonelectricalsolutions.com/property/124181920/998-s-cherry-av-tucson-az-85719) · Public records last checked 2026-08-16
- Parcel
- 124181920
- Built
- 1982 (assessor record)
- Jurisdiction
- Tucson
- Zoning
- I-1
- Assessor use
- Multiuse Or Miscellaneous Industrial
- Parcel size
- 0.11 acres
- Building area
- 1,955 sq ft (assessor record)
- Sewer
- Connection on file (1981) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 commercial building permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 commercial building permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
Industrial and warehouse space usually means three-phase motor loads. High-bay LED retrofits and added VFDs both change the load picture.
Recorded sales (1)
| Date | Price | Type |
|---|---|---|
| 2020-11-09 | $535,000 | Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2025-04-29 (TC-COM-0425-00861) — The Canary Systems PV system will consist of 30 Silab 520W modules and metal decking mounted on a new steel parking canopy. Microinverters will supply power through an existing TEP service..
Permit history (20)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2025-04-29finaled | TC-COM-0425-00861City permit record | Commercial BuildingThe Canary Systems PV system will consist of 30 Silab 520W modules and metal decking mounted on a new steel parking canopy. Microinverters will supply power through an existing TEP service. | Complete | |
| 2025-01-28finaled | TD-DEV-0125-00030City permit record | Development PackageThe Canary Systems PV system will consist of 30 modules plus metal decking on one new steel parking canopy in the existing parking lot. | Complete | |
| 2025-01-21expired 2025-09-08 | TC-UTL-0125-00005City permit record | Utilities· REMOVE (6) EXISTING ANTENNAS · REMOVE ALL EXISTING NOKIA RADIOS · REMOVE (12) LINES OF COAX · REUSE EXISTING (1) DC6-48-60-0-8C AND (1) DC6-48-60-0-8C-EV · REUSE (1) WCS-IMFQ-AMT FILTERS B1 · REMOVE EXISTING TMAs · INSTALL (3) 840-370966K ON POS A1/B1/C1 · INSTALL (3) AIR6419 B77D+AIR6419 B77G STACKED ON POS A2/B2/C2 · INSTALL (3) 840-370799K ON POS A3/B3/C3 · INSTALL (3) 4490 B5/B12A ON B2B'S TO BE SHARED W/ (3) 4415 B30S FOR P1 A/B/C TO BE INSTALLED ON (N) PIPES · INSTALL (3) 4890 B25/B66 ON B2B'S TO BE SHARED W/ (3) 4478 B14'S FOR P3 A/B/C TO BE INSTALLED ON (N) PIPES · REUSE EXISTING DC AND FIBER TRUNKS · INSTALL (2) NEW 6AWG POWER TRUNK · INSTALL (1) NEW DC9-48-60-24-8C-EV (SQUID) | Issued | |
| 2023-02-06finaled | TR-ROW-0223-00337City permit record | Fence / wallBehind our business as part of our property is a large fenced in yard where we have our garage. We currently have a fence around this yard with an electronic gate that is on a cement track (15'+9"). This gate allows access from the road, Warehouse Ave that runs along the northern edge of our property, to the yard and the garage. There is a 45" gap between the cement gate track and the curb at the street (Warehouse Ave). This 45" gap runs the length of the 15'+9" cement gate track. Currently there is loose dirt and gravel in this area. What we would like to do, and we appreciate your time looking at this, is we want to fill in that gap with cement. The pour would be from the gate track to the curb (45") along the entire 15'+9" length. | Complete | |
| 2022-07-19expired 2025-02-25 | T22CM05485City permit record | Commercial BuildingVerizon Wireless proposes to remove (1) microwave antenna and install (1) new microwave antenna. Als | Issued | |
| 2021-07-29finaled | T21RW03552City permit record | ROWNE corner of E Warehouse Ave and S Kino Pkwy. 230' Pull Through Existing Conduit 432ct Fiber into out of ROW. PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. OTHER ACTIVITIES IN THE AREA, WILL NEED TO COORDINATE TRAFFIC CONTROL SETUP WITH EXISTING SETUP. | Final | |
| 2021-01-14finaled | T21RW00197City permit record | ROWFrom the existing COX vault, SW Corner of 998 S Cherry Ave, begin 10' trench/bore placing 1-2'' conduit and 48ct fiber heading North to out of ROW | Final | |
| 2020-01-09finaled | T20CM00178City permit record | COMBOTI: OFFICE/ WAREHOUSE | Final |
Show 12 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2019-09-30finaled | T19RW05777City permit record | ROWJOB WILL REQUIRE ACCESS TO MH #11318 TO PLACE FIBER | Final | |
| 2017-03-07finaled | T17CM01822City permit record | COMBOREPL 12 ANTENNAS VERIZON | Final | |
| 2017-01-13finaled | T17CM00315City permit record | COMBOADDING NEW DIESEL DRIVEN GENERATOR | Final | |
| 2017-01-13 | T17CM00316City permit record | COMBOUPGRADE ELECTRICAL SERVICE FOR CELL TOWER | Withdrwn | |
| 2014-02-18expired 2014-12-27 | T14CM00925City permit record | COMBOREPLACE ANTENNAS AND ASSOCIATED EQUIPMENT | Expired | |
| 2012-06-11 | T12CM03377City permit record | COMBOREPLACEMENT OF EXISTING ANTENNA MOUNT, INSTALLATION OF 2 NE ANTENNAS PER SECTOR FOR 6 TOTAL. RELOCATION OF 2 EXISTING ANTENNAS, 3 NEW RRH'S, 1 NEW RAY CAP, 1 NEW GPS ANTENNA, INSTALLATION OF NEW BATTERY AND EQUIPMENT CABINET ON EXISTING PAD | Withdrwn | |
| 2011-06-27expired 2013-02-16 | T11CM01985City permit record | COMBOREPLACE ANTENNAS, ADD TOWER MOUNTED AMPLIFIERS, STRUCTURALLY REINFORCE TOWER | Si_xpire | |
| 2005-01-13 | T05CM00175City permit record | COMBOCELL TOWER:CO LOCATE ANTENNA ON EXISTING TOWER | Withdrwn | |
| 2002-12-27expired 2003-02-25 | T02EX01475City permit record | EXCAVEXCA:REPAIRSTO INSTALL 24LF OF FIBER OPTIC CONDUT | Closed | |
| 2002-12-16 | T02AN01150City permit record | ADDRNEW | Issued | |
| 2002-09-20finaled | T02CM04436City permit record | COMBOCELL SITE | Final | |
| 2000-07-26finaled | T00CM03700City permit record | Addition / alterationADDITION:CELLULAR EQUIPMENT BLDG/ANTENNA | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Send: the permanent link and the summary above, once. Watch: one email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list either way.
How this report was built
This is a reading of public records for parcel 124181920 — 20 permits on file from 2000 to 2025 (9 combo, 3 row, 2 commercial building, 1 development package) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.