Electrical permit history — 744 S Euclid Av

744 S Euclid Av, Tucson — built 1950, with 13 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

744 S Euclid Av

Built 1950 — 1950s commercial stock · 13 permits on record; no permitted panel/service or HVAC work among them

Parcel
12415014E
Built
1950 (assessor record)
Jurisdiction
Tucson
Zoning
I-1
Assessor use
Warehousing
Parcel size
0.98 acres
Building area
9,780 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 744 S Euclid Av, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2017 firecons permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2017 firecons permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2017 (9 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T17FC00888 — Install an XR150FC Fire/Security panel with a cellular transmitter to monitor the sprinkler riser
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2014-10-23$540,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2025-05-12 (TS-PRM-0525-00199) — Furnish & install non illuminated flat aluminum letters flush to fascia.

Permit history (13)

Permit history for this parcel — 8 of 13 records
DateRecordWhatStatusValue
2025-05-12expired 2025-12-03TS-PRM-0525-00199City permit recordSign - PermanentFurnish & install non illuminated flat aluminum letters flush to fasciaIssued
2023-03-22finaledTR-UTL-0323-01144City permit recordRight-of-Way (ROW) - UtilityN.987774 - KAHANA Boring - 0' Trenching - 18' Aerial - 1,967' Boring and/or Trenching to place new CTL Cabinet, plus other buried sections. Along with Aerial Over-Lash and Placement.Complete
2023-03-15TR-UTL-0323-01096City permit recordRight-of-Way (ROW) - UtilityP.987774 - KAHANA Boring - 350' Trenching - 25' Aerial - 2,049' Borning and/or Trenching to place new CTL Cabinet, plus other buried sections. Along with Areial Over-Lash and Placement.Withdrawn
2022-12-30expired 2023-06-28TS-PRM-1222-00101City permit recordSign - PermanentChange of copy on existing pole signIssued
2021-07-26finaledT21RW03465City permit recordROW(2) 5X5 bell holes in blacktop front, across the street (crews will be trenching across the street) --to repair/replace gas line ISSAP NPL PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING.Final
2019-06-17finaledT19RW03457City permit recordROWJob will require 5' of trenching 1-3 conduit that continues onto private property. Job will also require access to MH#8474 to splice fiber.Final
2019-05-07DP19-0118City permit recordDevelopment PackageSITE - Outdoor mobile office units.Fees due
2019-04-23finaledT19RW02260City permit recordROW(2) 5 X 5 BELLHOLES IN DIRT ALLEY -TO REPAIR/REPLACE GAS LINE POTHOLE NO WORK ON EUCLID AVFinal
Show 5 older records
Permit history for this parcel — remaining 5 records
DateRecordWhatStatusValue
2019-01-11finaledT19RW00185City permit recordROWN.443909 - This job trenches 5' of 2" PVC E/W 1-1.25" UV I.D. across S Euclid Ave, closest intersection E 18th St. It places 300' of 1.66" aerial futurepath across and through the E 18th St & S Euclid Ave intersection. 2 total anchors/down guys to be placed. Access to HH #8474 located on SW corner of E 18th St & S Euclid Ave.Final
2018-10-30expired 2019-01-04T18RW04845City permit recordROWThis job trenches 5' of 2" PVC E/W 1-1.25" UV I.D. across S Euclid Ave, closest intersection E 18th St. It places 300' of 1.66" aerial futurepath across and through the E 18th St & S Euclid Ave intersection. 2 total anchors/down guys to be placed. Access to HH #8474 located on SW corner of E 18th St & S Euclid Ave.Expired
2017-10-27finaledT17FC00888City permit recordFIRECONSInstall an XR150FC Fire/Security panel with a cellular transmitter to monitor the sprinkler riserFinal
2017-08-29expired 2018-02-25T17OT00882City permit recordSIGN1-NON ILLUM WAL SIGNExpired
2015-04-01T15CM02104City permit recordCOMBONEW COMMERICAL BUILDINGWithdrwn

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (2)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 2 of 2 records
DateRecordWhatStatus
2022-06-13T22DV03376Code enforcement caseCode enforcement caseComplian
2008-07-23T08DV06254Housing code violationSIGN VIOLATIONrecorded before 2023NOVERIFY

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 12415014E — 13 permits on file from 2015 to 2025 (5 row, 2 sign - permanent, 2 right-of-way (row) - utility, 1 development package) and 2 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.