Electrical permit history — 1034 E Broadway Bl

1034 E Broadway Bl, Tucson — built 1936, with 6 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

1034 E Broadway Bl

Built 1936 — 1930s commercial stock · last permitted panel/service work 2007 (finaled)

Parcel
124120070
Built
1936 (county record)
Jurisdiction
Tucson
Zoning
C-3
Assessor use
Auto Repair Garage Autos/Light Trucks
Parcel size
0.14 acres
Building area
2,591 sq ft (assessor record)
Sewer
Connection on file (1946) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Sunshine Mile Historic District — National Register district (City of Tucson)
Service on record
City records show the 2007 permit was finalized; the permit description states “Install 2"riser, 1- 200amp safety socket, 1- 200amp fused disconnect to repair existing service.”.

See the property

County aerial photograph centered on 1034 E Broadway Bl, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentLast permitted 2007 (19 years ago). City inspection record: ELECTRIC - FINAL approved 2008-01-03. Contractor of record: MEHL ELECTRIC SERVICE INC,*C. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T07EL02227 — Install 2"riser, 1- 200amp safety socket, 1- 200amp fused disconnect to repair existing service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2023-07-21$1,175,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2025-06-19 (TC-COM-0625-01190) — replace stolen service wires and damaged meter base and disconnect with new.

Permit history (6)

Permit history for this parcel — 6 of 6 records
DateRecordWhatStatusValue
2025-06-19expired 2026-03-10TC-COM-0625-01190City permit recordCommercial Buildingreplace stolen service wires and damaged meter base and disconnect with newInspections
2025-06-16TC-COM-0625-01160City permit recordElectrical reconnectVOID - WRONG WORK CLASS Please submit a new application utilizing the Commercial Trade Permit Work Class – Category Name: PDSD – Building Description: Triplex, Multi-Family, Industrial, Retail, Office, Self Storage, Parking Garage, or other Commercial property. Application for trade(s) work by a license AZROC contractor, including: - Electrical Service & Equipment: Upgrade, Replacement, or Installation (up to 400 amp) - Plumbing Fixture Replacement - Water Heater Installation - Other Fixed Appliance Installation (hardwired or plumbed) - *Water Service Line (from Meter to Building) Repair, replacement, or addition* - **Sewer Line (from Building drain to Sewer Main) Repair, replacement, or addition** - Furnaces (air handler/forced air) - Air Condensing Unit or Heat Pump (AC) - Mechanical Equipment Installation (Hood, exhaust, ventilation, etc) - Gas Services (LP or Natural Gas): New pipe, pipe repair, new gas appliance, reconnection - Other similar services (For over 400 amp service, please use the "Additions/Alterations" permit) (For Electrical Reconnect Only, please use the "Electrical Reconnect" permit) (For Fire Restoration or Code Violation abatement, please use the "Additions/Alterations" permit) (For demolition, please use the appropriate "Demolition" permit) For further information, please contact Doris Benoit at doris.benoit@tucsonaz.gov - 520.633.9084 replace stolen meter and disconnect with newVoid
2024-03-15TC-DMO-0324-00048City permit recordDemolitionPartial Demolition of buildingExpired
2014-08-22finaledT14OT01084City permit recordFence / wallPAINTED WALL SIGNFinal
2007-12-27finaledT07EL02227City permit recordELECTInstall 2"riser, 1- 200amp safety socket, 1- 200amp fused disconnect to repair existing service.Final
2001-03-09T01EL00567City permit recordELECTREPLACE:METERWithdrwn

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 124120070 — 6 permits on file from 2001 to 2025 (2 elect, 1 commercial building, 1 electrical reconnect, 1 demolition) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).