Electrical permit history — 990 E 9th St
990 E 9th St, Tucson — built 1940, with 10 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
990 E 9th St
Built 1940 — 1940s commercial stock · 10 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 990 E 9th St (aztucsonelectricalsolutions.com/property/12406151b/990-e-9th-st-tucson-az-85719) · Public records last checked 2026-08-16
- Parcel
- 12406151B
- Built
- 1940 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-1
- Assessor use
- Restaurant Sit Down
- Parcel size
- 0.37 acres
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Pie Allen Residential Historic District — National Register district (City of Tucson)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 fire construction permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 fire construction permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyCurrentLast permitted 2024 (2 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0624-00481 — New Fire Suppression System Install for Kitchen Hood
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
Food service carries heavy, cycling kitchen loads and exhaust interlocks. Capacity and existing panel space are the first things to verify on any remodel.
Most recent permit on record for this parcel: 2024-06-20 (TF-FCP-0624-00481) — New Fire Suppression System Install for Kitchen Hood.
Permit history (10)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2024-06-20finaled | TF-FCP-0624-00481City permit record | Fire ConstructionNew Fire Suppression System Install for Kitchen Hood | Complete | |
| 2021-05-27finaled | T21RW02621City permit record | ROWReplacing pole and overhead transformer NOTE: Proof of notification is required at the time of the preconstruction meeting. | Final | |
| 2020-12-28finaled | T20CM09036City permit record | Commercial BuildingTentant Improvement of existing restaurant to Pizza restaurant | Inspections complete | |
| 2019-04-01finaled | T19RW01724City permit record | ROWTRENCH IN ASPHALT 40 FT, PLACE FLUSH MOUNT VAULT 24" X 36" X 36" | Final | |
| 2005-10-14finaled | T05BU02540City permit record | BUILDKITCHEN EXHAUST HOOD FIRE SUPRESSION SYSTEM | Final | |
| 2005-07-29finaled | T05CM03995City permit record | COMBOTI:RESTAURANT | C of o | |
| 2005-07-21finaled | T05OT01799City permit record | SIGNSIGN:#9385 MCNESBY'S | Final | |
| 2005-05-09expired 2005-11-12 | T05EL00941City permit record | ELECTRECONNECT:ELECTRIC | Expired |
Show 2 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 1999-10-14finaled | T99OT00305City permit record | C-OF-OC OF O INSPECTION:COFFEE SHOP | C of o | |
| 1999-10-12expired 2000-05-28 | T99EL02681City permit record | ELECTSIGNS:CIRCUIT:9910057 | Expired |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (14)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2023-06-14 | CE-VIO0623-04055Code enforcement case | Vegetation | Closed - resolved |
| 2023-02-06 | CE-VIO0223-01763Code enforcement case | Fire | Closed - resolved |
| 2021-11-22 | T21DV08314Code enforcement case | Code enforcement case | Complian |
| 2021-02-22 | T21DV00985Code enforcement case | Code enforcement case | Complian |
| 2020-12-14 | T20DV07934Code enforcement case | Code enforcement case | Complian |
| 2020-12-07 | T20DV07795Code enforcement case | Code enforcement case | Complian |
| 2020-11-17 | T20DV07460Code enforcement case | Code enforcement case | Complian |
| 2020-01-16 | T20DV00366Code enforcement case | Fire | Complian |
Show 6 older records
| Date | Record | What | Status |
|---|---|---|---|
| 2010-03-25finaled | T10FR00661Code enforcement case | Code enforcement case | Complete |
| 2010-03-25finaled | T10FR00663Code enforcement case | Code enforcement case | Complete |
| 2010-03-11finaled | T10FR00559Code enforcement case | Fire | Complete |
| 2010-02-18finaled | T10FR00377Code enforcement case | Code enforcement case | Complete |
| 2006-06-19finaled | T06FR02028Code enforcement case | Code enforcement case | Complete |
| 2005-10-12 | T05ZV00525Code enforcement case | Code enforcement case | Complian |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, once. No list, no follow-up unless you ask for it.
How this report was built
This is a reading of public records for parcel 12406151B — 10 permits on file from 1999 to 2024 (2 row, 2 elect, 1 fire construction, 1 commercial building) and 14 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.