Electrical permit history — 1050 E 8th St

1050 E 8th St, Tucson — built 1968, with 25 permits on record. Review electrical, HVAC and remodel history with links to official records.

Multifamily property

1050 E 8th St

Built 1968 — 1960s multifamily stock · HVAC 2012 (permit expired without a confirmed final) · 2 open code cases

Parcel
12406132A
Built
1968 (county record)
Jurisdiction
Tucson
Zoning
R-3
Assessor use
Apartments 25 - 99 Units 3 Or More Story
Parcel size
1.35 acres
Building area
70,400 sq ft (assessor record)
Sewer
Connection on file (1978) (county sewer connection records)
Flood zone
AE — Special Flood Hazard Area (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 1050 E 8th St, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2011 floodpln permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalPermitted — completion not confirmedA 2012 permit specifies this work (the permit description states “CHILLER REPLACEMENT”), but the available record does not show a final inspection. The permit expired without a confirmed final status. Official status: Expired. City inspection record: ELECTRIC - FINAL approved 2013-07-11. Contractor of record: J4 DEVELOPMENT. T12CM08093 — CHILLER REPLACEMENT
  • Fire alarm & life safetyPermitted — completion not confirmedA 2023 permit specifies this work (the permit description states “Cellular dialer upgrade”), but the available record does not show a final inspection. The permit expired without a confirmed final status. Official status: Expired. TF-FCP-0523-00660 — Cellular dialer upgrade
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth looking at

    There are 2 open code enforcement cases on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2019-06-05$9,194,500Warranty Deed
2011-01-18$8,285,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-05-08 (TR-ROW-0526-00561) — Manhole bench rehab.

Permit history (25)

Permit history for this parcel — 8 of 25 records
DateRecordWhatStatusValue
2026-05-08finaledTR-ROW-0526-00561City permit recordRight-of-Way (ROW)Manhole bench rehabComplete
2025-10-06finaledTZ-CMP-1025-00172City permit recordZoning Verification LetterPlease provide a Zoning Verification Letter for address: 1050 East 8th Street (Parcel # 124-06-132A). Please do not exceed $153.06 in fees without prior approval. (Our Ref # 183872-1)Complete
2023-10-27finaledTZ-CMP-1023-00199City permit recordZoning Verification LetterDue Diligence ReportComplete
2023-05-04expired 2023-12-01TF-FCP-0523-00660City permit recordFire ConstructionCellular dialer upgradeExpired
2022-01-18expired 2022-07-18T22OT00027City permit recordFloodplain UseFUP FOR T20CM03594Issued
2020-12-21T20SA00379City permit recordZoning Verification LetterWILCAT VILLAGE - INDIVIDUAL PARKING PLAN - - NoSubmitted
2020-07-06expired 2022-07-18T20OT00473City permit recordFloodplain UseFUP FOR T20CM03593, T19CM05656Issued
2020-06-11expired 2024-06-06T20CM03593City permit recordCommercial BuildingLEASING CENTER REMODELIssued
Show 17 older records
Permit history for this parcel — remaining 17 records
DateRecordWhatStatusValue
2020-06-11expired 2024-06-06T20CM03594City permit recordCommercial BuildingFITNESS CENTER REMODELIssued
2019-10-23expired 2022-06-08DP19-0261City permit recordDevelopment PackageSITE - Wildcat Village, multi-family development.Issued
2019-08-07expired 2024-08-16T19CM05656City permit recordCommercial BuildingADDING 1 BED ROOM TO 52 UNITSIssued
2013-05-29finaledT13CM03249City permit recordCOMBOREPLACE DWV STACKS WITH ABS AND ADD GFCI CIRCUITFinal
2013-05-09expired 2013-07-08T13EX00656City permit recordEXCAVRAISE FRAME AND COVER TO GRADE AND INSTALL A CONCRETE COLLAR AT MH8583-28Closed
2012-12-21expired 2014-04-14T12CM08093City permit recordCOMBOCHILLER REPLACEMENTExpired
2012-05-24finaledT12CM02988City permit recordCOMBOREPLACE:DWV STACKS:ADD GFCIFinal
2012-02-21expired 2013-01-08T12CM00524City permit recordAddition / alterationADDITION:CABINETS FOR ADDRESSExpired
2012-01-24finaledT12OT00149City permit recordSIGNSIGN 20237Final
2011-12-12T11CM03786City permit recordCOMBOTI: MAIN LOBBY - COMMWithdrwn
2011-11-10DP11-0008City permit recordDEVPKGSKYVIEW APARTMENT RENOVATIONWithdrwn
2011-11-10finaledT11OT02134City permit recordFLOODPLNFLOODPLAIN USE PERMIT SKYVIEW APARTMENT RENOVATIONFinal
2008-07-01finaledT08EL01211City permit recordELECTREPAIR: ELECTRICAL PANELFinal
2008-06-16finaledT08OT01438City permit recordSIGN15149Final
1999-02-25finaledT99ME00251City permit recordMECHPRESSURE VESSEL CERTIFICATE:TUC-21202,22329,22328Final
1998-05-11finaledT98CM02037City permit recordCOMBOTI:OFFICE 93 SF TI. METAL STUDS W/ GYP BDC of o
1998-04-22finaledT98CM01741City permit recordCOMBOFIRE DAMAGE REPAIR- GROUND FLOOR-LOBBY AND CORRIDOREMOVE OFFICE,EPOXY INJECTION OF BEAM, REPLACE SUSPENDED CEILING SYSTEM, REPLACE DAMAGED DOORS, REPLACE EXIT HARDWARE AT EXIT DOORS,REPLACE WOOD PANELS FOR CLASS II RATING .C of o

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (15)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 15 records
DateRecordWhatStatus
2026-06-24CE-VIO0626-02651Code enforcement caseCode enforcement caseReceived
2026-02-17CE-VIO0226-00816Code enforcement caseCode enforcement caseActive
2024-08-27CE-VIO0824-03474Code enforcement caseCode enforcement caseClosed - unfounded
2022-06-15T22DV03430Code enforcement caseRefuseClosed - resolved
2022-04-07T22DV02308Code enforcement caseCode enforcement caseComplian
2022-03-23T22DV02001Code enforcement caseCode enforcement caseComplian
2021-08-12T21DV05285Code enforcement caseRefuseComplian
2021-08-07T21DV05119Code enforcement caseRefuseVoid
Show 7 older records
Code enforcement history for this parcel — remaining 7 records
DateRecordWhatStatus
2021-08-02T21DV04903Code enforcement caseRefuseComplian
2021-03-09T21DV01318Code enforcement caseRefuseNoverify
2015-10-30T15DV08352Code enforcement caseCode enforcement caseCancel
2012-04-30T12DV03500Code enforcement caseCode enforcement caseComplian
2007-09-07T07DV08925Code enforcement caseRefuseCancel
2003-06-03T03VL00549Code enforcement caseSignVoid
1999-11-15T99VL02835Code enforcement caseCode enforcement caseClosed

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 12406132A — 25 permits on file from 1998 to 2026 (6 combo, 3 zoning verification letter, 3 commercial building, 2 floodplain use) and 15 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.