Electrical permit history — 1150 E 8th St
1150 E 8th St, Tucson — built 1971, with 23 permits on record. Review electrical, HVAC and remodel history with links to official records.
Multifamily property
1150 E 8th St
Built 1971 — 1970s multifamily stock · 1 open code case · 23 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 1150 E 8th St (aztucsonelectricalsolutions.com/property/12406113a/1150-e-8th-st-tucson-az-85719) · Public records last checked 2026-08-16
- Parcel
- 12406113A
- Built
- 1971 (county record)
- Jurisdiction
- Tucson
- Zoning
- NR-3
- Assessor use
- Apartments 100+ Units 3 Or More Story
- Parcel size
- 2.04 acres
- Building area
- 94,744 sq ft (assessor record)
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Flood zone
- AE — Special Flood Hazard Area (FEMA)
- Historic preservation
- Rincon Heights Historic District — National Register district — Non-contributing (City of Tucson)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire construction permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire construction permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyCurrentLast permitted 2025 (1 year ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0425-00347 — Fire Alarm As-Built drawings.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Worth looking at
There is an open code enforcement case on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.
- Worth confirming
Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
Recorded sales (1)
| Date | Price | Type |
|---|---|---|
| 2001-07-31 | $4,430,000 | Special Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2025-04-30 (TF-FCP-0425-00347) — Fire Alarm As-Built drawings..
Permit history (23)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2025-04-30finaled | TF-FCP-0425-00347City permit record | Fire ConstructionFire Alarm As-Built drawings. | Complete | |
| 2024-07-08expired 2025-01-25 | TC-COM-0724-01320City permit record | Commercial BuildingAdding panelboard to 4th floor. Panelboard to be used to supply future fire alarm system components. Future fire alarm system under separate permit. REV1: Updated address on plans and permit. | Fees due | |
| 2021-09-14finaled | T21RW04252City permit record | ROWFROM TEP POLE ON NW CORNER OF 1150 E 8TH ST., TRENCH/BORE 5' TO PLACE RISER ON NEW POLE. TIE IN. PREVIOUSLY APPROVED UNDER T21RW02381 ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. FLOODPLAIN USE PERMIT REQUIRED 1. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. 2. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. 3. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. 4. MAINTAIN PEDESTRIAN ACCESS | Final | |
| 2021-05-14finaled | T21RW02381City permit record | ROWFROM TEP POLE ON NW CORNER OF 1150 E 8TH ST., TRENCH/BORE 5' TO PLACE RISER ON NEW POLE. TIE IN. OTHER ACTIVITIES IN THE AREA, WILL NEED TO COORDINATE TRAFFIC CONTROL SETUP WITH EXISTING SETUP. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. | Final | |
| 2019-11-26finaled | T19RW07218City permit record | ROWTEP WILL BE WORKING IN ROW TO INSTALL AN OVERHEAD TRANSFORMER ON EXISTING WO 6290151 | Final | |
| 2019-09-17finaled | T19CM06755City permit record | COMBO(T19DV00933) LIGHTING UPGRADE TO THE OUTSIDE OF BLDG | Final | |
| 2019-06-05expired 2020-07-01 | T19FC00429City permit record | Fire ConstructionFire Alarm & Detection Systems - MONITORING SWITCHOVER; Fire Alarm Systems - Monitoring Modification | Expired | |
| 2019-03-26finaled | T19RW01639City permit record | ROWStart Point: From the TEP pole on the West Side of 1150 E 8th St, begin 1116' overlash heading North , continue 735' overlash heading East, riser down and begin 30' trench bore heading East. Continue 230' bore/trench heading North. place 3x3 pothole and continue 35' trench/ bore heading West . Continue South 25' trench/bore placing new COX vault. head West 20' trench/bore to vault, tie in | Final |
Show 15 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2018-06-18finaled | T18RW02717City permit record | ROWStart point- From the TEP pole in front of 3321 N Fremont Drive begin 381' relash/delash heading South to TEP pole, tie in. | Final | |
| 2018-05-24finaled | T18RW02392City permit record | ROWTrench in pavement 1,561 ft of 6" steel in joint trench with 4" PE main and 22 ft of 6" steel in right of way. Trench in pavement 114 ft of 4" PE main, 44 ft of 2" PE main, and 5 ft of 1" PE main in right of way. Trench 646 ft of PE service in pavement and 293 ft of PE service in dirt in right of way. One 5'x5' bellhole in Pavement on Tyndall Ave near 822 East 5th St for pipe maintenance. All other installation is to be done on private property. *Installation is on 8th St - Santa Rita Ave to Park Ave & Park Ave - 8th St to 7th St *1473' of steel main to be re-tested on Tyndall Ave - 5th St to 7th St & 7th St to Park Ave, no surface impact besides 5'x5' bellhole listed above | Final | |
| 2017-07-06finaled | T17CM05191City permit record | Fence / wallCAR INTO WALL REPAIR | Final | |
| 2014-06-03expired 2014-11-30 | T14OT00695City permit record | SIGN2 BANNERS 06/03/2014-09/01/2014 | Expired | |
| 2013-05-09expired 2013-07-08 | T13EX00655City permit record | EXCAVRAISE FRAME AND COVER TO GRADE AND INSTALL A CONCRETE COLLAR AT MH8583-27 | Closed | |
| 2009-06-09expired 2009-08-08 | T09EX00316City permit record | EXCAVEXCA:226' DIRT 60'ASPHALT DRIVEWAY TO TRENCH/BORE TO PLACE 2"PVC. BORING FORM ON FILE | Closed | |
| 2008-01-28finaled | T08OT00223City permit record | SIGN14279 | Final | |
| 2008-01-08 | T08OT00038City permit record | Floodplain UseFLOODPLAIN USE PERMIT | Submitted | |
| 2003-04-24finaled | T03EL00784City permit record | ELECTELECTRIC:RECONNECT | Final | |
| 2002-08-06finaled | T02OT01194City permit record | SIGNSIGN:4306 | Final | |
| 2002-05-10finaled | T02CM02358City permit record | COMBOREMODEL:APARTMENTS 72 UNITS | Final | |
| 2001-05-29 | T01OT00148City permit record | SITESITE REVIEW:PARKING LOT ONLY | Withdrwn | |
| 2000-10-10 | T00ME01052City permit record | MECHPRESSURE VESSEL INSPECTION: TUC-23606 | Withdrwn | |
| 2000-10-10finaled | T00ME01055City permit record | MECHPRESSURE VESSEL INSPECTION: TUC-23606 | Final | |
| 1999-02-05expired 1999-12-06 | T99CM00510City permit record | COMBOREPLACE CHILLER & BOILERS | Closed |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (9)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2026-07-28 | CE-VIO0726-03145Code enforcement case | Refuse | Received |
| 2024-06-21 | CE-VIO0624-02385Code enforcement case | Electrical | Closed - resolved |
| 2022-10-20 | T22DV06079Code enforcement case | Code enforcement case | Closed - resolved |
| 2019-02-13 | T19DV00933Code enforcement case | Code enforcement case | Complian |
| 2017-05-08 | T17DV01900Code enforcement case | Code enforcement case | Complian |
| 2016-06-20 | T16DV03625Code enforcement case | Code enforcement case | Complian |
| 2016-06-20 | T16DV03627Code enforcement case | Code enforcement case | Cancel |
| 2015-03-03 | T15DV01545Code enforcement case | Code enforcement case | Noverify |
Show 1 older record
| Date | Record | What | Status |
|---|---|---|---|
| 2008-12-22finaled | T08FR04777Code enforcement case | Fire | Complete |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Send: the permanent link and the summary above, once. Watch: one email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list either way.
How this report was built
This is a reading of public records for parcel 12406113A — 23 permits on file from 1999 to 2025 (6 row, 3 combo, 3 sign, 2 fire construction) and 9 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.