Electrical permit history — 326 N Fremont Av

326 N Fremont Av, Tucson — built 1949, with 12 permits on record. Review electrical, HVAC and remodel history with links to official records.

Multifamily property

326 N Fremont Av

Built 1949 — 1940s multifamily stock · last permitted panel/service work 2015 (finaled)

Parcel
124060720
Built
1949 (county record)
Jurisdiction
Tucson
Zoning
NR-3
Assessor use
Apartments 5 To 24 Units
Parcel size
0.23 acres
Building area
3,105 sq ft (assessor record)
Sewer
Connection on file (1949) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Rincon Heights Historic District — National Register district — Contributing (City of Tucson)
Service on record
City records show the 2015 permit was finalized; the permit description states “UPGRADE UP TO 200AMP” — an increase in capacity as described, not a confirmed installed rating.

See the property

County aerial photograph centered on 326 N Fremont Av, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentLast permitted 2015 (11 years ago). City inspection record: ELECTRIC - FINAL approved 2016-08-12. Contractor of record: CAROLE ELECTRIC CORPORATION ** APA **. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T15CM08943 — UPGRADE UP TO 200AMP
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2017 combo permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Solar was permitted here in 2015. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2000-05-18$199,900Joint Tenancy Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-02-02 (TR-ROW-0226-00131) — Sidewalk repair per PAG SD 200 for NOV received..

Permit history (12)

Permit history for this parcel — 8 of 12 records
DateRecordWhatStatusValue
2026-02-02finaledTR-ROW-0226-00131City permit recordRight-of-Way (ROW)Sidewalk repair per PAG SD 200 for NOV received.Complete
2017-06-07finaledT17CM04480City permit recordCOMBOADD PHOTOVOLTAIC SYSTEM AND RELATED MATERIALSFinal
2015-12-23finaledT15CM08943City permit recordCOMBOUPGRADE UP TO 200AMPFinal
2015-12-07finaledT15CM08534City permit recordSolar PVADD SOLAR AND ASSOCIATED EQUIPMENTFinal
2012-01-17finaledT12EL00135City permit recordELECTUPGRADE ELECTRIC UP TO 200 AMPS; APTS- T12DV00114Final
2012-01-17finaledT12EL00136City permit recordELECTUPGRADE ELECTRIC UP TO 200 AMPS; APTSFinal
2012-01-17finaledT12EL00137City permit recordELECTUPGRADE ELECTRIC UP TO 300 AMPS; APTSFinal
2006-03-17finaledT06PL00466City permit recordPLUMBREPL GAS LINEFinal
Show 4 older records
Permit history for this parcel — remaining 4 records
DateRecordWhatStatusValue
2005-10-07finaledT05PL01626City permit recordPLUMBRE-CONNECT: GASFinal
2000-06-07T00AN00396City permit recordADDRNEWIssued
2000-06-07T00AN00397City permit recordADDRNEWIssued
2000-06-07T00AN00398City permit recordADDRNEWIssued

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (2)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 2 of 2 records
DateRecordWhatStatus
2012-01-09T12DV00114Code enforcement caseElectricalComplian
2011-08-03T11DV06222Code enforcement caseCode enforcement caseNoverify

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 124060720 — 12 permits on file from 2000 to 2026 (3 elect, 3 addrnew, 2 combo, 2 plumb) and 2 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.