Electrical permit history — 1614 E 1st St
1614 E 1st St, Tucson — built 1985, with 14 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
1614 E 1st St
Built 1985 — 1980s commercial stock · 14 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 1614 E 1st St (aztucsonelectricalsolutions.com/property/124020540/1614-e-1st-st-tucson-az-85719) · Public records last checked 2026-08-16
- Parcel
- 124020540
- Built
- 1985 (county record)
- Jurisdiction
- Tucson
- Zoning
- R-3
- Assessor use
- State School Prop
- Parcel size
- 0.17 acres
- Sewer
- Connection on file (2014) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
Most recent permit on record for this parcel: 2026-08-10 (TF-FOP-0826-01051) — Yearly.
Permit history (14)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-08-10finaled | TF-FOP-0826-01051City permit record | Fire OperationalYearly | Inspections complete | |
| 2026-01-06finaled | TF-FOP-0126-00020City permit record | Fire OperationalFraternity | Complete | |
| 2025-09-19 | TC-COM-0925-01712City permit record | Commercial BuildingVOID: DS - Same permit type and scope of work as existing application permit TC-COM-0925-01691. Please resubmit under existing permit. If you made any changes to your plans, please resubmit your revised plans and a detailed revision narrative/comment response letter that clearly explains how you revised the plans and where the revisions can be found on the plan sheets. It looks like the address was added and you just need to upload the revised file to permit TC-COM-0925-01691. Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf For questions: Building_Official@tucsonaz.gov Gas needs turned back on to the facility as soon as possible. Fraternity Building. Tucson plumbing has replaced gas ball valves in the kitchen. | Void | |
| 2025-09-17expired 2026-03-24 | TC-COM-0925-01691City permit record | Commercial BuildingIn Kitchen, Tucson plumbing replaced faulty gas ball valve. Need permit for southwest gas to turn gas back on to the facility | Inspections | |
| 2025-09-17 | TC-RES-0925-04578City permit record | Trade permitVOID: Wrong Permit Type. We were unable to intake your request for gas work under a Residential Trade Permit. The use as a fraternity house require that this request be submitted under a Commercial Trade Permit. This permit will be voided. For questions: Building_Official@tucsonaz.gov Gas ball valved replaced in Kitchen. Need Permit for Southwest gas to reconnect gas service for the facility | Void | |
| 2025-06-24finaled | TC-COM-0625-01208City permit record | Commercial BuildingREPLACE 2 100GAL GAS WATER HEATERS | Complete | |
| 2024-11-19finaled | TF-FOP-1124-01342City permit record | Fire OperationalFraternity Facility | Complete | |
| 2023-09-11finaled | TF-FOP-0923-01490City permit record | Fire OperationalSigma Phi Epsilon Fraternity | Complete |
Show 6 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2022-08-24finaled | T22FO00727City permit record | FIREOPERSIGMA PHI EPSILON - OCC 273 | Final | |
| 2021-10-21finaled | T21FO00737City permit record | FIREOPEROCC 273 | Final | |
| 2019-12-03finaled | T19FO01072City permit record | FIREOPEROCC LOAD 273 | Final | |
| 2015-10-28finaled | T15BU01259City permit record | Fence / wallBLOCK WALL, HEIGHT EXTENSION | Final | |
| 2014-04-21expired 2023-04-05 | T14BU00420City permit record | BUILDFIRE ALARM | Closed | |
| 2003-12-10finaled | T03BU03099City permit record | DEMODEMO:FRATERNITY | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Send: the permanent link and the summary above, once. Watch: one email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list either way.
How this report was built
This is a reading of public records for parcel 124020540 — 14 permits on file from 2003 to 2026 (4 fire operational, 3 commercial building, 3 fireoper, 1 trade permit) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.