Electrical permit history — 1339 E 1st St
1339 E 1st St, Tucson — built 1960, with 33 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
1339 E 1st St
Built 1960 — 1960s commercial stock · 33 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 1339 E 1st St (aztucsonelectricalsolutions.com/property/12401002b/1339-e-1st-st-tucson-az-85719) · Public records last checked 2026-08-16
- Parcel
- 12401002B
- Built
- 1960 (county record)
- Jurisdiction
- Tucson
- Zoning
- R-3
- Assessor use
- Club Lodge Fraternal/Sorority
- Parcel size
- 0.83 acres
- Building area
- 20,844 sq ft (assessor record)
- Sewer
- Connection on file (1945, 2016, 2017) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire construction permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire construction permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyCurrentLast permitted 2025 (1 year ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0525-00407 — EXPEDITE - Retrofit existing Fire Alarm System and devices. EST IO1000 and Cellular Dialer. WOULD LIKE TO REQUEST EXPEDITED REVIEW PROCESS. WORKS NEEDS TO COMPLETE DURING SUMMER BREAK.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
Most recent permit on record for this parcel: 2026-04-10 (TC-COM-0426-00520) — Selective remodel of an existing Sorority house consisting of both inside and outside elements..
Permit history (33)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-04-10expires 2027-08-16 | TC-COM-0426-00520City permit record | Commercial BuildingSelective remodel of an existing Sorority house consisting of both inside and outside elements. | Inspections | |
| 2025-05-21finaled | TF-FCP-0525-00407City permit record | Fire ConstructionEXPEDITE - Retrofit existing Fire Alarm System and devices. EST IO1000 and Cellular Dialer. WOULD LIKE TO REQUEST EXPEDITED REVIEW PROCESS. WORKS NEEDS TO COMPLETE DURING SUMMER BREAK. | Complete | |
| 2025-03-27finaled | TC-COM-0325-00621City permit record | Addition / alterationThe owner would like to appeal the current occupancy of the sleeping porch to allow additional occupants. No changes to the building are planned. | Complete | |
| 2024-10-22finaled | TF-FOP-1024-01208City permit record | Fire OperationalAlpha Phi - Beta Epsilon sorority | Complete | |
| 2024-08-22finaled | TR-UTL-0824-01586City permit record | Right-of-Way (ROW) - UtilityPRJ276557-1 overlash 532', 448ct fiber to existing. for CATV system tie | Complete | |
| 2023-09-06finaled | TF-FOP-0923-01469City permit record | Fire OperationalAlpha Phi - Beta Epsilon Sorority House | Complete | |
| 2022-09-28finaled | T22FO00835City permit record | FIREOPERALPHA PHI - BETA EPSILON SORORITY HOUSE | Final | |
| 2021-12-02finaled | T21FO00838City permit record | FIREOPEROCC 314 | Final |
Show 25 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2021-07-21finaled | T21FC00577City permit record | FIRECONSNFP to modify the existing fire sprinkler system. | Final | |
| 2021-06-16finaled | T21FC00486City permit record | FIRECONSInstallation of an Ansul Fire Suppression System for kitchen hood | Final | |
| 2019-11-29finaled | T19FO01056City permit record | FIREOPEROCC LOAD 314 | Final | |
| 2019-06-04finaled | T19CM03940City permit record | COMBOADD NEW KITCHEN | Final | |
| 2019-04-22expired 2020-06-02 | DP19-0098City permit record | Addition / alterationSITE - Alpha Phi, addition and renovation of 380 SF kitchen to existing building. | Issued | |
| 2017-08-02 | T17FC00633City permit record | FIRECONSMODIFY EXISTING, ADD ONE HORN/STROBE | Void | |
| 2017-06-19finaled | T17FC00505City permit record | FIRECONSModify the Existing Fire Sprinkler System - Add 70 sprinklers and relocate/replace 33 | Final | |
| 2017-06-12finaled | T17FC00487City permit record | DemolitionDemolition and Rebuild of 2nd Half - Utilizing existing Panel | Final | |
| 2017-03-08finaled | T17BU00105City permit record | DEMOPARTIAL DEMO OF BUILDING | Final | |
| 2017-02-22finaled | T17CM01430City permit record | COMBOSORORITY | C of o | |
| 2016-07-06expired 2023-04-10 | T16BU01024City permit record | SPKLRSPRINKLER | Closed | |
| 2016-06-29finaled | T16BU00992City permit record | BUILDFIRE ALARM | Final | |
| 2016-05-25expired 2016-11-21 | T16BU00812City permit record | TANKSTANK | Expired | |
| 2016-04-21finaled | T16CM02925City permit record | Addition / alteration1250 SF NEW ADDITION | C of o | |
| 2016-04-07finaled | DP16-0061City permit record | Addition / alterationADDITION RENOVATION ALPAHPHI | Complete | |
| 2015-06-16finaled | T15BU00680City permit record | SPKLRRELOCATE 5 FIRE SPRINKLERS NO PLANS | Final | |
| 2015-06-05finaled | T15CM03786City permit record | COMBOT.I;KITCHEN | L of c | |
| 2013-02-15finaled | T13CM00920City permit record | COMBOTI: DORM | Final | |
| 2012-06-18finaled | T12CM03565City permit record | COMBOELECTRICAL IMPROVEMENTS | Final | |
| 2012-02-10finaled | T12EL00366City permit record | ELECTADDT OF RECEPTACLES, LIGHTS AND CEILING FANS IN WATER DAMAGED ROOM | Final | |
| 2012-01-13finaled | T12PL00086City permit record | PLUMBREPLACE: GAS LINE - RES | Final | |
| 2005-07-01finaled | T05PL01094City permit record | PLUMBINSTALL: GREASE INTERCEPTOR | Final | |
| 2000-07-10expired 2001-01-09 | T00CM03394City permit record | COMBOINSTALL:HVAC | Closed | |
| 2000-05-16expired 2000-07-15 | T00EX00726City permit record | EXCAVEXCAV:18 LF | Closed | |
| 1998-06-04expired 1999-07-06 | T98CM02465City permit record | COMBOAIR COND:REPLACEMENTS | Closed |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (9)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2012-01-12 | T12DV00230Code enforcement case | Fire | Complian |
| 2011-04-18 | T11DV02593Code enforcement case | Code enforcement case | Invalid |
| 2009-10-28finaled | T09FR03398Code enforcement case | Fire | Complete |
| 2009-07-20finaled | T09FR02354Code enforcement case | Code enforcement case | Complete |
| 2008-10-07finaled | T08FR03579Code enforcement case | Fire | Complete |
| 2008-02-15finaled | T08FR00488Code enforcement case | Code enforcement case | Complete |
| 2006-11-28finaled | T06FR02789Code enforcement case | Code enforcement case | Complete |
| 2005-09-21finaled | T05FR01478Code enforcement case | Code enforcement case | Complete |
Show 1 older record
| Date | Record | What | Status |
|---|---|---|---|
| 2004-09-15finaled | T04FR00374Code enforcement case | Code enforcement case | Complete |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, once. No list, no follow-up unless you ask for it.
How this report was built
This is a reading of public records for parcel 12401002B — 33 permits on file from 1998 to 2026 (7 combo, 4 addition / alteration, 4 firecons, 3 fireoper) and 9 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.