Electrical permit history — 2200 E Elm St
2200 E Elm St, Tucson — built 1924, with 37 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
2200 E Elm St
Built 1924 — 1920s commercial stock · last permitted panel/service work 2017 (finaled) · HVAC 2019 (finaled) · 1 open code case
Permanent link: Electrical permit history for 2200 E Elm St (aztucsonelectricalsolutions.com/property/12306022g/2200-e-elm-st-tucson-az-85719) · Public records last checked 2026-08-16
- Parcel
- 12306022G
- Built
- 1924 (county record)
- Jurisdiction
- Tucson
- Zoning
- R-2
- Assessor use
- Resort
- Parcel size
- 7.69 acres
- Building area
- 83,901 sq ft (assessor record)
- Sewer
- Connection on file (2006) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Blenman-Elm Historic District — National Register district (City of Tucson)
- Service on record
- City records show the 2017 permit was finalized; the permit description states “(6) 5X5 bellholes in blktop/concrete --to install new service Approx (3) 7 ft trenches- totaling 21 ft trench Work order #'s 3509782, 3463760, 3503759”.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionCurrentLast permitted 2017 (9 years ago). City inspection record: last recorded inspection 2018-01-18; no approved final is shown. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T17RW05278 — (6) 5X5 bellholes in blktop/concrete --to install new service Approx (3) 7 ft trenches- totaling 21 ft trench Work order #'s 3509782, 3463760, 3503759
- Heating, cooling & mechanicalCurrentLast permitted 2019 (7 years ago). City inspection record: MECHANICAL - FINAL approved 2019-08-07. Contractor of record: ADVANCED MECHANICAL SERVICES LLC. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T19CM05561 — REPL AIR HANDLER
- Fire alarm & life safetyLikely dueLast permitted 2006 (20 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T06BU01506 — FIRE SPRK: NEW 80 AND ADD 218' OF 4" UNDERGROUND
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Worth looking at
There is an open code enforcement case on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
Recorded sales (1)
| Date | Price | Type |
|---|---|---|
| 2025-09-30 | $21,125,000 | Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2026-06-17 (TC-COM-0626-00914) — New Semipublic Hydrotherapy Spa for Arizona Inn.
Permit history (37)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-06-17expires 2027-07-23 | TC-COM-0626-00914City permit record | Pool / spaNew Semipublic Hydrotherapy Spa for Arizona Inn | Inspections | |
| 2026-04-23expires 2026-10-13 | TR-ROW-0426-00471City permit record | Right-of-Way (ROW)for install of gas conduit at public alley behind Arizona Inn. 07/14/26- Renew permit for 90 days as of 07/15/26 new expiration date is 10/13/26. | Inspections | |
| 2025-12-30 | TC-COM-1225-02346City permit record | Commercial BuildingBuilding C1 Triplex | Expired | |
| 2025-12-30 | TC-COM-1225-02348City permit record | Commercial Building[WROG PERMIT TYPE] Building C2 Triplex | Void | |
| 2025-12-30 | TC-MDP-1225-00818City permit record | Model BuildingVOID: It appears the construction plans submitted are the same as the construction plans submitted under permit TC-MDP-1225-00817. Please submit a new permit with the correct plans under a new permit. This permit has been VOIDED. Building C1 Triplex | Void | |
| 2025-07-28finaled | TZ-CMP-0725-00137City permit record | Zoning Verification LetterA zoning determination request for the Arizona Inn's eligibility for the Community Corridors Tool. | Complete | |
| 2025-07-10finaled | TZ-CMP-0725-00126City permit record | Zoning Verification Letter*Zoning Compliance/Verification Letter: Please supply a letter stating in which zoning district the subject property is currently located and any overlay districts, whether or not it is considered to be a permitted use, and any compliance information you may be able to provide. *Any Variances, Special Permits or Conditions: Please note the existence of these items as they relate to the subject property and supply documentation, if available. | Complete | |
| 2024-05-03 | TR-ROW-0524-00532City permit record | Right-of-Way (ROW)( Denied - DUPLICATE REQUEST - REFER TO PERMIT REQUEST TR-ROW-0524-00528 Review Notes. "Submit Traffic Control plan and Site Plan (Google Image) of work area" through permit TR-ROW-0524-00528) We will be removing several large trees from the Arizona Inn property. We will need the road closed so our crane service and hauling trucks can have access to the trees. | Void |
Show 29 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2024-05-02finaled | TR-ROW-0524-00528City permit record | Right-of-Way (ROW)We will be removing several large trees from the Arizona Inn property. We will need the road closed so our crane service and hauling trucks can have access to the trees. | Complete | |
| 2019-08-05finaled | T19CM05561City permit record | COMBOREPL AIR HANDLER | Final | |
| 2018-12-19finaled | T18CM09863City permit record | COMBONEW ELECTRICAL PANEL | Final | |
| 2018-11-09finaled | T18RW05038City permit record | ROWREMOVING TREE USING CRANE-CLOSE WILSON FROM ELM TO ADAMS | Final | |
| 2017-12-12finaled | T17RW05479City permit record | ROWEMERGENCY (2) 5 X 5 BELLHOLES IN DIRT/BLKTOP FRONT TO REPAIR EMERGENCY LEAK PLEASE CONTACT SAMMY RODRIGUEZ FOR ANY QUESTIONS | Final | |
| 2017-12-08finaled | T17CM09068City permit record | COMBOREPAIR/REPL GAS LINE | Final | |
| 2017-11-27finaled | T17RW05278City permit record | ROW(6) 5X5 bellholes in blktop/concrete --to install new service Approx (3) 7 ft trenches- totaling 21 ft trench Work order #'s 3509782, 3463760, 3503759 | Final | |
| 2017-10-16finaled | T17CM07793City permit record | COMBOREPLACE/REPAIR GAS LINE | Final | |
| 2017-08-31finaled | T17RW03892City permit record | ROWNEW GAS LINE AND SERVICE TO FEED ARIZONA INN. INSTALL NEW GAS MAIN AND GAS SERVICE IN THE ROW ELM STREET AND WILSON AVENUE | Final | |
| 2017-06-08finaled | T17RW02453City permit record | ROWREMOVING 2 TREES AT ARIZONA INN USING HOOK CRANE | Final | |
| 2017-01-31expired 2018-04-24 | T17CM00775City permit record | COMBOREPL HVAC KITCHEN AREA | Expired | |
| 2015-09-01expired 2016-05-17 | T15CM06093City permit record | Pool / spaDEMO & RECONSTRUCT POOL GAZEBO | Expired | |
| 2014-08-06finaled | T14CM05022City permit record | COMBOCONNECT CHILLER PIPING AND ELECTRICAL, INSTALL REFER MONITOR | Final | |
| 2012-03-16finaled | T12CM01150City permit record | COMBOADD; (1) 200 AMP PANEL, AND 2 ELECTRIC VEHICLE STATIONS FOR ARIZONA INN | Final | |
| 2010-01-11expired 2011-01-07 | T10ME00024City permit record | MECHREPLACE: 2 TON ROOFTOP GAS PACK (APA) | Closed | |
| 2008-10-22finaled | T08BU01885City permit record | BUILDPAINT BOOTH HOOD SYSTEM | Final | |
| 2008-01-11finaled | T08CM00113City permit record | COMBOTI:HOTEL (ELECTRIC / MECHANICAL/PLBG ONLY) | Final | |
| 2007-05-10expired 2009-06-13 | T07CM01970City permit record | COMBOUPGRADE:HVAC | Closed | |
| 2006-07-19expired 2006-09-17 | T06EX00872City permit record | EXCAVTRENCH 26'P AND 4'D | Closed | |
| 2006-06-13finaled | T06BU01506City permit record | SPKLRFIRE SPRK: NEW 80 AND ADD 218' OF 4" UNDERGROUND | Final | |
| 2005-12-06finaled | T05EL02416City permit record | ELECTUPGRADE:ELECTRIC | Final | |
| 2005-12-02finaled | T05CM06003City permit record | COMBOTI: HOTEL | C of o | |
| 2000-10-16expired 2001-04-14 | T00ME01115City permit record | MECHPRESSURE VESSEL INSPECTION: TUC-24061 | Withdrwn | |
| 2000-07-05finaled | T00PL01260City permit record | PLUMBWATER LINE:REPLACEMENT | Final | |
| 1999-07-09finaled | T99ME00744City permit record | MECHEXHAUST HOOD REPLACEMENT | Final | |
| 1999-06-22finaled | T99BU01662City permit record | BUILDFIRE SUPPRESSION SYSTEM | Final | |
| 1998-02-25finaled | T98EX00236City permit record | EXCAVEXCAV:5 X 5 MANHOLE IN STREET | Final | |
| 1997-10-24finaled | T97BU02189City permit record | BUILDANSUL FIRE SYSTEM | Final | |
| 1996-11-20finaled | T96EX00448City permit record | EXCAV15LF INTO ALLEY FOR UTILS | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (6)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2026-02-19 | CE-VIO0226-00879Code enforcement case | Code enforcement case | Active |
| 2010-07-14finaled | T10FR01338Code enforcement case | Fire | Complete |
| 2009-12-02finaled | T09FR03675Code enforcement case | Fire | Complete |
| 2009-09-15finaled | T09FR03023Code enforcement case | Code enforcement case | Complete |
| 2009-06-25 | T09DV03652Code enforcement case | Work without permit | Noverify |
| 2008-04-21 | T08FR01005Code enforcement case | Fire | Field |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Send: the permanent link and the summary above, once. Watch: one email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list either way.
How this report was built
This is a reading of public records for parcel 12306022G — 37 permits on file from 1996 to 2026 (10 combo, 5 row, 3 right-of-way (row), 3 mech) and 6 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.