Electrical permit history — 1944 N Tucson Bl

1944 N Tucson Bl, Tucson — built 1941, with 12 permits on record. Review electrical, HVAC and remodel history with links to official records.

Multifamily property

1944 N Tucson Bl

Parcel
123021950
Built
1941 (county record)
Jurisdiction
Tucson
Zoning
R-2
Assessor use
Apartments 5 - 24 Units 1 Story
Parcel size
0.79 acres
Service on record
A 2023 permit was issued; completion is not confirmed in the available record; the permit description states “Service upgrade from 60 amps to 100 amps 240 volts single phase” — an increase in capacity as described, not a confirmed installed rating.

Is it time to upgrade?

  • Electrical service & distributionPermitted — completion not confirmedA 2023 permit specifies this work (the permit description states “Service upgrade from 60 amps to 100 amps 240 volts single phase”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Issued. TC-RES-0323-03820 — Service upgrade from 60 amps to 100 amps 240 volts single phase
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2024-06-20 (TC-COM-0624-01179) — Gas line replacement from Meter to appliances using black iron pipe and fittings.

Permit history (12)

Permit history for this parcel — 8 of 12 records
DateRecordWhatStatusValue
2024-06-20expired 2025-01-12TC-COM-0624-01179City permit recordCommercial BuildingGas line replacement from Meter to appliances using black iron pipe and fittingsIssued
2023-03-31expired 2024-09-17TC-RES-0323-04021City permit recordResidential Building - One or Two FamilyUpgrading from 60 amps per unit to 100 amps per unit/240 volts. Using a 4 meter pack with main breakers.Issued
2023-03-23expired 2024-03-26TC-RES-0323-03820City permit recordResidential Building - One or Two FamilyService upgrade from 60 amps to 100 amps 240 volts single phaseIssued
2023-03-23expired 2024-03-26TC-RES-0323-03822City permit recordResidential Building - One or Two FamilyUpgrade 60 amp service to 100 amps 240 voltsIssued
2023-03-03expired 2024-09-22TC-RES-0323-03288City permit recordResidential Building - One or Two FamilyElectrical service upgrade from 60 amps to 100 amps 240 voltsIssued
2019-02-01finaledT19CM00779City permit recordCOMBOELECTRICAL UPGRADE NO MORE THAN 200 AMPS DUAL METERFinal
2016-08-15finaledT16CM06334City permit recordCOMBOREPL MTR 100 AMPFinal
2015-02-06finaledT15CM00815City permit recordCOMBOREPLACE/REPAIR GAS LINEFinal
Show 4 older records
Permit history for this parcel — remaining 4 records
DateRecordWhatStatusValue
2014-02-11finaledT14CM00833City permit recordCOMBOREPLACING GAS LINEFinal
2010-10-19expired 2011-04-18T10PL01596City permit recordPLUMBRES REPL GAS LINESExpired
2002-01-16T02AN00046City permit recordADDRNEWIssued
2002-01-16finaledT02PL00147City permit recordPLUMBREROUTE:GAS LINEFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (3)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 3 of 3 records
DateRecordWhatStatus
2013-03-18T13DV01622Code enforcement caseCode enforcement caseComplian
2011-11-14T11DV09266Code enforcement caseCode enforcement caseNoverify
2006-10-05T06VL01327Code enforcement caseRefuseComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

A plain-English brief of everything above — what the record shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
What describes you?
Call (520) 308-6235

How this report was built

This is a reading of public records for parcel 123021950 — 12 permits on file from 2002 to 2024 (4 residential building - one or two family, 4 combo, 2 plumb, 1 commercial building) and 3 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.