Electrical permit history — 2500 E Grant Rd

2500 E Grant Rd, Tucson — built 2009, with 14 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

2500 E Grant Rd

Build year not published — permits on file from 2009 · 1 open code case · 14 permits on record; no permitted panel/service or HVAC work among them

Parcel
12302085A
Built
2009 (earliest permit on file)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Retail Strip Center
Parcel size
1.73 acres
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Blenman-Elm Historic District — National Register district (City of Tucson)

See the property

County aerial photograph centered on 2500 E Grant Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2022 firecons permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2022 firecons permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentA newer 2022 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “Fire Alarm & Detection Systems - SUITE 142 - ADDITION OF FIRE ALARM DEVICES TO EXISTING SYSTEM.; Fire Alarm Systems - Devices Modified: 3; Work Started Without Approved Permit”. Last permitted 2022 (4 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T22FC00154 — FIRE SPRINKLER TI
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Worth looking at

    There is an open code enforcement case on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.

  • Worth confirming

    A pool or spa was permitted in 2022. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Era-based check

    A capacity and condition review is the usual starting point before any tenant improvement or added load. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2025-08-15 (TR-UTL-0825-01352) — Cox to aerial overlash 456' and pull 265' of fiber through existing conduit on private for system tie..

Permit history (14)

Permit history for this parcel — 8 of 14 records
DateRecordWhatStatusValue
2025-08-15finaledTR-UTL-0825-01352City permit recordRight-of-Way (ROW) - UtilityCox to aerial overlash 456' and pull 265' of fiber through existing conduit on private for system tie.Complete
2024-12-10TC-COM-1224-02326City permit recordCommercial BuildingRepair and replaced wiring inside the juction boxes, replace outlets, replace cords for all equipmentInspections
2024-12-09TC-COM-1224-02314City permit recordCommercial BuildingVOID PER MATTHEW CARLTON - Electrical repairsVoid
2024-08-30finaledTR-UTL-0824-01629City permit recordRight-of-Way (ROW) - Utilitywo 2871798 2500 e grant rd 14-14-05 ne leaking main 6lf/scComplete
2023-09-18finaledTR-ROW-0923-01154City permit recordRight-of-Way (ROW)manhole reconstruction on the right lane east bound. travel Lane ****(Work to be performed for Pima County Conveyance)***Complete
2022-04-11finaledT22RW01413City permit recordPool / spaPLACEMENT OF BARRICADES IN RIGHT-OF-WAY FOR SEAL COATING PARKING LOT OUT TO RIGHT OF WAY. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. BUS STOP IN THE AREA, CONTACT SUN TRAN DISPATCH, AT 520-206-8934 AND/OR BEA PAULUS AT 520-206-8826 AT LEAST 48-BUSINESS HOURS PRIOR TO START OF WORK FOR COORDINATION.Final
2022-03-22expired 2023-05-03T22FC00215City permit recordAddition / alterationFire Alarm & Detection Systems - SUITE 142 - ADDITION OF FIRE ALARM DEVICES TO EXISTING SYSTEM.; Fire Alarm Systems - Devices Modified: 3; Work Started Without Approved PermitExpired
2022-03-02finaledT22FC00154City permit recordFIRECONSFIRE SPRINKLER TIFinal
Show 6 older records
Permit history for this parcel — remaining 6 records
DateRecordWhatStatusValue
2021-08-09finaledT21OT00582City permit recordSign - PermanentCanopy sign per master sign program MSP-19-06Allow 50 sqft sign area each on east and west elevaComplete
2021-05-21finaledT21CM04357City permit recordCOMBOSALONC of o
2020-01-16expired 2020-07-29T20OT00057City permit recordSign - Permanent3 canopy signs / faux neon channel lettersExpired
2020-01-13expired 2020-08-31T20FC00016City permit recordFire ConstructionFire Alarm & Detection Systems - SNOOZE - NEW FIRE ALARM; Fire Alarm Systems - Devices Modified: 19Expired
2019-08-15T19CM05844City permit recordCommercial BuildingUNDERGROUND PLUMBINGCanceled
2018-08-10finaledDP18-0195City permit recordDevelopment PackageE SITE/GRADE/SWPPP - Snooze.Inspections complete

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (9)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 9 records
DateRecordWhatStatus
2026-06-03CE-VIO0626-02393Code enforcement caseWork without permitActive
2024-12-09CE-VIO1224-04887Code enforcement caseFireClosed - resolved
2019-12-18T19DV09453Housing code violationSIGN VIOLATIONrecorded before 2023NOVERIFY
2019-11-15T19DV08923Housing code violationCOMMERCIAL ZONINGrecorded before 2023NOVERIFY
2018-10-26T18DV06998Housing code violationWORK WITHOUT PERMITS-RESIDENTLrecorded before 2023COMPLIAN
2016-04-05T16DV02136Housing code violationSIGN VIOLATIONrecorded before 2023COMPLIAN
2014-12-09T14DV10012Housing code violationSIGN VIOLATIONNotice of violation issued · recorded before 2023COMPLIAN
2010-11-11T10DV08218Housing code violationCAR THROUGH COMMERCIAL BUILDINrecorded before 2023COMPLIAN
Show 1 older record
Code enforcement history for this parcel — remaining 1 records
DateRecordWhatStatus
2009-04-06T09DV01764Housing code violationSIGN VIOLATIONNotice of violation issued · recorded before 2023COURTCMP

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 12302085A — 14 permits on file from 2018 to 2025 (3 commercial building, 2 right-of-way (row) - utility, 2 sign - permanent, 1 right-of-way (row)) and 9 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.