Electrical permit history — 3002 E Grant Rd

3002 E Grant Rd, Tucson — built 1947, with 24 permits on record. Review electrical, HVAC and remodel history with links to official records.

Multifamily property

3002 E Grant Rd

Built 1947 — 1940s multifamily stock · last permitted panel/service work 2004 (finaled) · 3 open code cases

Parcel
123020080
Built
1947 (county record)
Jurisdiction
Tucson
Zoning
C-1
Assessor use
Apartments 5 - 24 Units 1 Story
Parcel size
0.46 acres
Building area
4,512 sq ft (assessor record)
Sewer
Connection on file (1954) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Blenman-Elm Historic District — National Register district (City of Tucson)
Service on record
City records show the 2004 permit was finalized; the permit description states “UPGRADE:ELECTRIC 30AMP TO 100AMP (APA)” — an increase in capacity as described, not a confirmed installed rating.

See the property

County aerial photograph centered on 3002 E Grant Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentLast permitted 2004 (22 years ago). City inspection record: ELECTRIC - FINAL approved 2005-01-19. Contractor of record: NIGHT OWL ELECTRIC. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T04EL02163 — UPGRADE:ELECTRIC 30AMP TO 100AMP (APA)
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth looking at

    There are 3 open code enforcement cases on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2017. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Worth confirming

    A pool or spa was permitted in 2004. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

Recorded sales (4)

Recorded transfers from the Pima County Assessor — 4 of 4
DatePriceType
2004-06-30$370,000Contract or Agreement
2002-11-18$245,000Warranty Deed
2000-08-24$205,000Warranty Deed
1998-07-30$225,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-05-29 (TC-COM-0526-00787) — fire in unit 1 next door. Code enforcement violation. No damage to unit. Utilities turned off.

Permit history (24)

Permit history for this parcel — 8 of 24 records
DateRecordWhatStatusValue
2026-05-29TC-COM-0526-00787City permit recordCommercial Buildingfire in unit 1 next door. Code enforcement violation. No damage to unit. Utilities turned offAwaiting submittal
2026-05-29expires 2027-08-14TC-COM-0526-00788City permit recordFence / wallFire damage repair. Fire contained to this unit. Replace electrical, replace drywall, cabinets (2500.00)Issued
2026-05-29expires 2027-06-24TC-COM-0526-00790City permit recordCommercial BuildingVacant unit, electrical panel tampered with by vandal. Replace stolen ground wire. owner has the dead front. code enforcement violationIssued
2024-11-08expired 2024-12-08SP-NRP-1124-00129City permit recordElectrical reconnect*VOID - Existing work permit. Complete Inspections or Sub-Record on Active Permit (The City of Tucson has not approved your Electrical Reconnect Only application. Our records indicate active code violations at this location, CE-VIO0924-03543 for Unit 1 and CE-VIO0924-03542 for Unit 2. To continue your electrical reconnect request, you will need to complete a sub-record permit under Commercial Addition/Alteration. The permit will require a complete set of plans that address all of the building repairs that are referenced in the building code violation.)* - - power off due to fire called in by code enforcement - -Denied
2023-08-09finaledTC-RES-0823-07189City permit recordResidential Building - One or Two Familypower off 6 monthsComplete
2021-02-19finaledT21CM01498City permit recordCOMBOwater heater repair and pex installation like for likeFinal
2017-08-02finaledT17CM05927City permit recordCOMBO(T17DV02519) REPL JUNCTION BOX & BREAKER BOXFinal
2017-06-29finaledT17CM05067City permit recordElectrical reconnectELECTRICAL RECONNECTFinal
Show 16 older records
Permit history for this parcel — remaining 16 records
DateRecordWhatStatusValue
2016-03-15expired 2016-10-03T16CM01970City permit recordCOMBOWATERLINE REPAIR;APTExpired
2014-05-22finaledT14CM03063City permit recordCOMBOREPLACE WATER HEATERFinal
2009-06-16expired 2010-01-03T09CM01540City permit recordCOMBOBASEBOARD HEATERExpired
2004-11-29finaledT04BU02880City permit recordPool / spaDEMO: 30FT X 10 FT POOLFinal
2004-11-10expired 2008-06-01T04CM04980City permit recordCOMBOCODE COMPLIANCE REISSUED PERMIT TO BE FOR CODE COMPLIANCE OF ALL TRADESExpired
2004-11-10expired 2008-07-21T04CM04981City permit recordCOMBOCODE COMPLIANCE/ WATER HEATER FLUE PIPE FIX AND WATER LINESExpired
2004-11-10finaledT04ME00744City permit recordFence / wallCODE COMPLIANCE/ REPLACE WALL HEATER IN LIVING ROOMFinal
2004-11-10finaledT04ME00745City permit recordMECHCODE COMPLIANCE / DUCT REPAIRFinal
2004-10-26finaledT04EL02163City permit recordELECTUPGRADE:ELECTRIC 30AMP TO 100AMP (APA)Final
2004-10-26finaledT04EL02164City permit recordELECTUPGRADE:ELECTRIC 30AMP TO 100AMP (APA)Final
2004-10-26finaledT04EL02165City permit recordELECTUPGRADE:ELECTRIC 30AMP TO 100AMP (APA)Final
2004-10-26finaledT04EL02166City permit recordELECTUPGRADE:ELECTRIC 30AMP TO 100AMP (APA)Final
2004-02-03finaledT04EL00207City permit recordELECTRECONNECT:ELECTRIC:APARTMENTFinal
2001-04-23expired 2008-05-28T01PL00881City permit recordPLUMBWATER HEATER:REPLACEMENTClosed
1998-07-13finaledT98EL01261City permit recordELECTELECTRIC:GENERAL REPAIRFinal
1998-06-02finaledT98PL01157City permit recordPLUMBGAS LINE:REPAIRS 7 UNITS 3,4,7-11Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (76)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 76 records
DateRecordWhatStatus
2026-03-19CE-VIO0326-01295Code enforcement caseElectricalActive
2026-03-19CE-VIO0326-01308Code enforcement caseElectricalCitation
2026-01-27CE-VIO0126-00430Code enforcement caseGraffitiClosed - unfounded
2025-09-30CE-VIO0925-04324Code enforcement caseRefuseClosed - resolved
2025-09-25CE-VIO0925-04256Code enforcement caseCode enforcement caseCitation
2025-02-07CE-VIO0225-00607Code enforcement caseCode enforcement caseClosed - resolved
2024-09-02CE-VIO0924-03542Code enforcement caseFireClosed - resolved
2024-09-02CE-VIO0924-03543Code enforcement caseFireClosed - resolved

68 older records are not shown here. — each links to its official file.

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 123020080 — 24 permits on file from 1998 to 2026 (7 combo, 6 elect, 2 commercial building, 2 fence / wall) and 76 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.