Electrical permit history — 3719 E Speedway Bl
3719 E Speedway Bl, Tucson — built 1976, with 20 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
3719 E Speedway Bl
Built 1976 — 1970s commercial stock · 20 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 3719 E Speedway Bl (aztucsonelectricalsolutions.com/property/12218257a/3719-e-speedway-bl-tucson-az-85716) · Public records last checked 2026-08-16
- Parcel
- 12218257A
- Built
- 1976 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-2
- Assessor use
- Restaurant Sit Down
- Parcel size
- 0.68 acres
- Building area
- 5,454 sq ft (assessor record)
- Sewer
- Connection on file (2010) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2013 spklr permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2013 spklr permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyCurrentLast permitted 2013 (13 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T13BU00970 — RELOCATE 3 FIRE SPRINKLERS
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
Food service carries heavy, cycling kitchen loads and exhaust interlocks. Capacity and existing panel space are the first things to verify on any remodel.
- Worth confirming
Solar equipment was permitted here in 2013 — the permit category covers PV, solar water heating and pool heating alike. If it was PV, there is an existing interconnection and the busbar already carries backfeed, which constrains what else can be added under the 120% rule; a thermal system carries no such constraint. Worth confirming which it is.
Recorded sales (1)
| Date | Price | Type |
|---|---|---|
| 2009-12-29 | $390,000 | Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2023-09-08 (TR-ROW-0923-01133) — **** Withdrawn - Duplicate Permit *** We need a lane closure to pull our equipment out and load from a private property. (I need an extension due to the monsoons canceling the original scheduled date of work)..
Permit history (20)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2023-09-08 | TR-ROW-0923-01133City permit record | Right-of-Way (ROW)**** Withdrawn - Duplicate Permit *** We need a lane closure to pull our equipment out and load from a private property. (I need an extension due to the monsoons canceling the original scheduled date of work). | Withdrawn | |
| 2023-06-28finaled | TR-ROW-0623-00913City permit record | Right-of-Way (ROW)We need a lane closure to pull our equipment out and load from a private property. | Complete | |
| 2018-10-10finaled | T18FO00880City permit record | FIREOPERRESTAURANT OCC-LOAD: 156 | Final | |
| 2016-09-22expired 2017-05-02 | T16CM07299City permit record | Addition / alterationWALL ADDITION TO ENCLOSE INTO STORAGE ROOM | Expired | |
| 2013-08-27finaled | T13BU00970City permit record | SPKLRRELOCATE 3 FIRE SPRINKLERS | Final | |
| 2013-08-20finaled | DP13-0159City permit record | Development PackageSITE | Complete | |
| 2013-08-19expired 2014-03-23 | T13CM05094City permit record | COMBOTI/ENCLOSE PATIO; RESTAURANT | Expired | |
| 2013-05-28finaled | T13CM03207City permit record | Solar PVSOLAR HOT WATER SYSTEM | Final |
Show 12 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2010-09-15finaled | T10BU01426City permit record | BUILDKITCHEN EXHAUST HOODS | Final | |
| 2010-07-29expired 2010-09-27 | T10EX00376City permit record | EXCAVEXCA: 25'DRIVEWAY W/2-25'CURB RETURNS | Closed | |
| 2010-07-21finaled | T10OT01560City permit record | SIGN18663 | Final | |
| 2010-06-17finaled | T10BU00976City permit record | SPKLRInstall 114 fire sprinklers | Final | |
| 2010-06-10finaled | T10EL01400City permit record | ELECTTEMP 200 AMP PEDESTAL | Final | |
| 2010-04-27expired 2010-06-26 | T10EX00206City permit record | EXCAVTRENCH 6'P AND 9' SIDEWALK PAVERS (INSTALL 4" FIRE SERVICE ) APA | Closed | |
| 2010-03-05finaled | T10CM00544City permit record | COMBONEW RESTAURANT; "FEAST RESTAURANT" | C of o | |
| 2010-02-10finaled | T10CM00308City permit record | COMBOSITE ONLY : Feast | Final | |
| 2010-01-22 | T10AN00040City permit record | ADDRNEW | Issued | |
| 2007-12-27expired 2009-03-11 | T07BU02671City permit record | BUILDKITCHEN EXHAUST HOOD FIRE | Closed | |
| 2006-03-10finaled | T06OT00682City permit record | SIGN10797 | Final | |
| 1999-09-01finaled | T99EL02263City permit record | ELECTSIGN:ELECTRIC:9909006 | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (11)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2018-02-15 | T18DV00852Code enforcement case | Vegetation | Noverify |
| 2015-02-11 | T15DV00872Code enforcement case | Code enforcement case | Noverify |
| 2010-02-04 | T10DV00526Code enforcement case | Code enforcement case | Noverify |
| 2010-01-13 | T10DV00204Code enforcement case | Graffiti | Noverify |
| 2007-12-05finaled | T07FR02474Code enforcement case | Fire | Complete |
| 2007-07-20finaled | T07FR01363Code enforcement case | Fire | Complete |
| 2006-05-03finaled | T06FR01177Code enforcement case | Code enforcement case | Complete |
| 2005-07-18 | T05VL00594Code enforcement case | Sign | Complian |
Show 3 older records
| Date | Record | What | Status |
|---|---|---|---|
| 2000-07-19 | T00VL00975Code enforcement case | Sign | Complian |
| 1999-10-12 | T99VL02637Code enforcement case | Sign | Complian |
| 1999-06-07 | T99VL01545Code enforcement case | Sign | Complian |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, once. No list, no follow-up unless you ask for it.
How this report was built
This is a reading of public records for parcel 12218257A — 20 permits on file from 1999 to 2023 (3 combo, 2 right-of-way (row), 2 spklr, 2 build) and 11 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).