Electrical permit history — 3636 E Bellevue St
3636 E Bellevue St, Tucson — built 1947, with 18 permits on record. Review electrical, HVAC and remodel history with links to official records.
Multifamily property
3636 E Bellevue St
Built 1947 — 1940s multifamily stock · last permitted panel/service work 2006 (finaled) · 1 open code case
Permanent link: Electrical permit history for 3636 E Bellevue St (aztucsonelectricalsolutions.com/property/122182240/3636-e-bellevue-st-tucson-az-85716) · Public records last checked 2026-08-16
- Parcel
- 122182240
- Built
- 1947 (county record)
- Jurisdiction
- Tucson
- Zoning
- R-2
- Assessor use
- Apartments 5 - 24 Units 1 Story
- Parcel size
- 0.58 acres
- Building area
- 4,228 sq ft (assessor record)
- Sewer
- Connection on file (1955) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- City records show the 2006 permit was finalized; the permit description states “REPLACE & UPGRADE TO 400 AMP MULTI METERING SECTION” — an increase in capacity as described, not a confirmed installed rating.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionCurrentLast permitted 2006 (20 years ago). City inspection record: ELECTRIC - FINAL approved 2007-03-09. Contractor of record: GOERING ELECTRIC L L C *C. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T06EL01144 — REPLACE & UPGRADE TO 400 AMP MULTI METERING SECTION
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Worth looking at
There is an open code enforcement case on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.
- Worth confirming
Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
There is an electrical reconnect permit from 2014. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.
Recorded sales (6)
| Date | Price | Type |
|---|---|---|
| 2022-04-18 | $585,000 | Warranty Deed |
| 2016-08-08 | $385,000 | Warranty Deed |
| 2008-03-05 | $375,000 | Warranty Deed |
| 2005-07-27 | $380,000 | Warranty Deed |
| 2003-09-16 | $320,000 | Joint Tenancy Deed |
| 2000-12-01 | $288,000 | Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2022-08-17 (T22CM06313) — Inspect the HP so that TEP can re-connect ASAP! It was disconnected during change of ownership back in April 2022. TEP won't turn it on w/out City's permission..
Permit history (18)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2022-08-17finaled | T22CM06313City permit record | COMBOInspect the HP so that TEP can re-connect ASAP! It was disconnected during change of ownership back in April 2022. TEP won't turn it on w/out City's permission. | Final | |
| 2014-10-29finaled | T14CM07316City permit record | COMBORECONNECT: ELECTRIC | Final | |
| 2013-05-08finaled | T13CM02792City permit record | COMBOUPGRADE ELECTRIC TO 100 AMPS | Final | |
| 2008-10-03finaled | T08PL01445City permit record | PLUMBGAS RECONNECT | Final | |
| 2008-10-03finaled | T08PL01446City permit record | PLUMBGAS RECONNECT | Final | |
| 2008-06-11 | T08PL00942City permit record | PLUMBNEW GAS METERS | Withdrwn | |
| 2006-06-15finaled | T06EL01144City permit record | ELECTREPLACE & UPGRADE TO 400 AMP MULTI METERING SECTION | Final | |
| 2006-06-15finaled | T06EL01145City permit record | ELECTRELOCATE & UPGRADE TO 400 AMP MULTI METERING SECTION | Final |
Show 10 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2000-05-04finaled | T00EL01144City permit record | ELECTSERVICE:NEW METER | Final | |
| 1999-11-08finaled | T99EL02899City permit record | ELECTUPGRADE:ELECTRIC 60AMP TO 200AMP | Final | |
| 1997-06-03expired 1997-11-30 | T97PL00596City permit record | PLUMBGAS PIPING | Expired | |
| 1997-06-03expired 1997-11-30 | T97PL00597City permit record | PLUMBGAS REPIPE | Expired | |
| 1997-06-03expired 1997-11-30 | T97PL00598City permit record | PLUMBGAS PIPING | Expired | |
| 1997-06-03expired 1997-11-30 | T97PL00599City permit record | PLUMBGAS REPIPE | Expired | |
| 1997-06-03expired 1997-11-30 | T97PL00600City permit record | PLUMBGAS REPIPE | Closed | |
| 1997-06-02expired 1997-08-01 | T97EX00775City permit record | EXCAV5X5 CUT | Closed | |
| 1997-05-21expired 1997-11-26 | T97PL00540City permit record | PLUMBGAS REPIPE:HOT WATER HEATER | Expired | |
| 1997-05-08expired 1997-11-05 | T97PL00475City permit record | PLUMBGAS REPAIR | Expired |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (9)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2026-07-20 | CE-VIO0726-03040Code enforcement case | Vegetation | Received |
| 2014-09-09 | T14DV07100Code enforcement case | Vegetation | Complian |
| 2014-09-09 | T14DV07101Code enforcement case | Refuse | Complian |
| 2014-05-19 | T14DV03167Code enforcement case | Code enforcement case | Noverify |
| 2014-04-15 | T14DV02377Code enforcement case | Code enforcement case | Complian |
| 1999-04-06 | T99VL00952Code enforcement case | Code enforcement case | Closed |
| 1999-04-06 | T99VL00953Code enforcement case | Code enforcement case | Closed |
| 1998-11-12 | T98VL01225Code enforcement case | Code enforcement case | Closed |
Show 1 older record
| Date | Record | What | Status |
|---|---|---|---|
| 1998-10-27 | T98VL01113Code enforcement case | Code enforcement case | Closed |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, once. No list, no follow-up unless you ask for it.
How this report was built
This is a reading of public records for parcel 122182240 — 18 permits on file from 1997 to 2022 (10 plumb, 4 elect, 3 combo, 1 excav) and 9 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.