Electrical permit history — 1411 N Alvernon Wy

1411 N Alvernon Wy, Tucson — built 1962, with 34 permits on record. Review electrical, HVAC and remodel history with links to official records.

Multifamily property

1411 N Alvernon Wy

Built 1962 — 1960s multifamily stock · 1 open code case · 34 permits on record; no permitted panel/service or HVAC work among them

Parcel
12218141A
Built
1962 (county record)
Jurisdiction
Tucson
Zoning
R-3
Assessor use
Apartments 5 - 24 Units 2 Story
Parcel size
0.60 acres
Building area
20,384 sq ft (assessor record)
Sewer
Connection on file (1962) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 1411 N Alvernon Wy, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth looking at

    There is an open code enforcement case on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2012. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

Most recent permit on record for this parcel: 2026-06-12 (TC-COM-0626-00877) — PROPOSED WORK IS FIRE, SMOKE AND WATER DAMAGE REPAIR AND REBUILD. LIKE FOR LIKE. POWER POLE FELL ON ROOF. DAMAGING UNIT 207. IGNITING A FIRE. FIRE DAMAGE WAS TO ROOF. WATER AND SMOKE DAMAGE OCCURED TO UNIT 207, 206, 107 AND 106. EXTERIOR WALLS, DOORS AND WINDOWS AND INTERIOR WALLS OK TO REMAIN AS IS. ALL NEW INTERIOR FINISH, MECHANICAL AND PLUMBING FIXTURES..

Permit history (34)

Permit history for this parcel — 8 of 34 records
DateRecordWhatStatusValue
2026-06-12TC-COM-0626-00877City permit recordFence / wallPROPOSED WORK IS FIRE, SMOKE AND WATER DAMAGE REPAIR AND REBUILD. LIKE FOR LIKE. POWER POLE FELL ON ROOF. DAMAGING UNIT 207. IGNITING A FIRE. FIRE DAMAGE WAS TO ROOF. WATER AND SMOKE DAMAGE OCCURED TO UNIT 207, 206, 107 AND 106. EXTERIOR WALLS, DOORS AND WINDOWS AND INTERIOR WALLS OK TO REMAIN AS IS. ALL NEW INTERIOR FINISH, MECHANICAL AND PLUMBING FIXTURES.Approved - awaiting customer attention
2026-06-12TC-COM-0626-00878City permit recordFence / wallPROPOSED WORK IS FIRE, SMOKE AND WATER DAMAGE REPAIR AND REBUILD. LIKE FOR LIKE. POWER POLE FELL ON ROOF. DAMAGING UNIT 207. IGNITING A FIRE. FIRE DAMAGE WAS TO ROOF. WATER AND SMOKE DAMAGE OCCURED TO UNIT 207, 206, 107 AND 106. EXTERIOR WALLS, DOORS AND WINDOWS AND INTERIOR WALLS OK TO REMAIN AS IS. ALL NEW INTERIOR FINISH, MECHANICAL AND PLUMBING fixturesApproved - awaiting customer attention
2026-06-12TC-COM-0626-00879City permit recordFence / wallPROPOSED WORK IS FIRE, SMOKE AND WATER DAMAGE REPAIR AND REBUILD. LIKE FOR LIKE. POWER POLE FELL ON ROOF. DAMAGING UNIT 207. IGNITING A FIRE. FIRE DAMAGE WAS TO ROOF. WATER AND SMOKE DAMAGE OCCURED TO UNIT 207, 206, 107 AND 106. EXTERIOR WALLS, DOORS AND WINDOWS AND INTERIOR WALLS OK TO REMAIN AS IS. ALL NEW INTERIOR FINISH, MECHANICAL AND PLUMBING fixturesApproved - awaiting customer attention
2026-05-01TE-FPU-0526-00164City permit recordFence / wallPDSD: determine the finished floor elevation related to: TC-COM-0426-00492, TC-COM-0626-00879, TC-COM-0626-00878, TC-COM-0626-00877 COST TO REPAIR FOR: proposed work is fire, smoke and water damage repair and rebuild. like for like. power pole fell on roof. damaging unit 207. igniting a fire. fire damage was to roof. water and smoke damage occured to unit 207, 206, 107 and 106. exterior walls, doors and windows and interior walls ok to remain as is. all new interior finish, mechanical and plumbing fixtures.Awaiting submittal
2026-04-08TC-COM-0426-00492City permit recordFence / wallUNIT #106 PERMIT - proposed work is fire, smoke and water damage repair and rebuild. like for like. power pole fell on roof. damaging unit 207. igniting a fire. fire damage was to roof. water and smoke damage occured to unit 207, 206, 107 and 106. exterior walls, doors and windows and interior walls ok to remain as is. all new interior finish, mechanical and plumbing fixtures. 600000.00Awaiting submittal
2025-12-15TC-COM-1225-02270City permit recordCommercial BuildingGas Line Reconnect. No work being doneExpired
2025-11-28TC-COM-1125-02161City permit recordCommercial BuildingThis Unit, #203, had a previous Tenant that occupied it since 2012 that never turned on the gas for heat. We need a permit to get a gas meter approved for southwest gas' installation.Expired
2022-10-17finaledT22CM07975City permit recordCommercial BuildingPRESSURE TEST ONLY FOR GAS RECONNECTComplete
Show 26 older records
Permit history for this parcel — remaining 26 records
DateRecordWhatStatusValue
2013-08-23finaledT13CM05249City permit recordCOMBOREPLACE TWO WATER HEATERS IN LAUNDRY ROOMFinal
2012-04-12finaledT12CM01898City permit recordCOMBORECONNECT:ELECTRIC:APTFinal
2011-07-19expired 2012-01-23T11EL01936City permit recordELECTRECONNECT ELECTRIC; APTSExpired
2011-07-19expired 2012-01-23T11EL01937City permit recordELECTRECONNECT ELECTRIC; APTSExpired
2011-07-19expired 2012-01-23T11EL01938City permit recordELECTRECONNECT ELECTRIC; APTSExpired
2011-07-19expired 2012-01-23T11EL01939City permit recordELECTRECONNECT ELECTRIC; APTSExpired
2011-03-14finaledT11EL00751City permit recordELECTRECONNECT:ELECTRIC APTFinal
2010-11-12finaledT10EL02580City permit recordELECTELECTRIC:REPLACE PANEL APTSFinal
2010-11-09T10EL02558City permit recordELECTReplace damaged 5 pack meter panelWithdrwn
2010-09-22expired 2011-04-25T10EL02207City permit recordELECTRECONNECT:ELECTRIC:APTExpired
2010-09-16expired 2011-04-25T10EL02150City permit recordELECTELEC RECONNECTExpired
2010-05-24finaledT10EL01236City permit recordELECTRECONNECT:ELECTRIC:APTFinal
2010-04-23finaledT10EL00959City permit recordELECTRECONNECT: ELECTRIC; APT # 106Final
2008-01-02finaledT08PL00008City permit recordPLUMBGAS RECONNECT (APA)Final
2006-12-08expired 2007-07-25T06PL02278City permit recordPLUMBRECONNECT:GAS LINE:APTSExpired
2005-12-07finaledT05PL01984City permit recordPLUMBRECONNECT:GASFinal
2005-12-07finaledT05PL01985City permit recordPLUMBRECONNECT:GASFinal
2005-11-17finaledT05EL02312City permit recordELECTGENERAL ELECTRIC REPAIR (APA)Final
2003-10-15finaledT03EL02040City permit recordELECTELECTRIC:RECONNECTFinal
1998-10-16P98AN02623City permit recordADDRNEWIssued
1998-10-16T98EL01886City permit recordELECTEXPIREDWithdrwn
1998-10-16finaledT98EL01887City permit recordELECTREPAIR:ELECTRICFinal
1998-10-16finaledT98EL01888City permit recordELECTREPAIR:ELECTRICFinal
1998-10-16finaledT98EL01889City permit recordELECTREPAIR:ELECTRICFinal
1998-10-16finaledT98EL01890City permit recordELECTREPAIR:ELECTRICFinal
1998-10-16finaledT98EL01891City permit recordELECTREPAIR:ELECTRICFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (14)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 14 records
DateRecordWhatStatus
2024-10-17CE-VIO1024-04183Code enforcement caseFireActive
2018-12-21T18DV08184Code enforcement caseCode enforcement caseReferred
2013-07-25T13DV05395Code enforcement caseRefuseNoverify
2008-04-16T08DV03101Code enforcement caseSignCourtcmp
2007-12-03T07DV12746Code enforcement caseCode enforcement caseComplian
2007-07-02T07DV06050Code enforcement caseCode enforcement caseComplian
2007-06-28T07DV05967Code enforcement caseCode enforcement caseComplian
2006-08-29T06DV01166Code enforcement caseCode enforcement caseComplian
Show 6 older records
Code enforcement history for this parcel — remaining 6 records
DateRecordWhatStatus
2006-01-30T06VL00136Code enforcement caseFireComplian
2004-12-01T04DV00943Code enforcement caseCode enforcement caseVoid
2004-05-24T04DV00431Code enforcement caseCode enforcement caseComplian
2003-08-19T03DV00777Code enforcement caseCode enforcement caseComplian
2000-10-03T00VL01379Code enforcement caseElectricalClosed
1999-02-02T99VL00333Code enforcement caseCode enforcement caseClosed

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 12218141A — 34 permits on file from 1998 to 2026 (19 elect, 5 fence / wall, 4 plumb, 3 commercial building) and 14 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.