Electrical permit history — 3155 E Speedway Bl
3155 E Speedway Bl, Tucson — built 1986, with 27 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
3155 E Speedway Bl
Built 1986 — 1980s commercial stock · last permitted panel/service work 2021 (permitted, completion not confirmed) · HVAC 2010 (permit expired without a confirmed final) · 1 open code case
Permanent link: Electrical permit history for 3155 E Speedway Bl (aztucsonelectricalsolutions.com/property/12217297d/3155-e-speedway-bl-tucson-az-85716) · Public records last checked 2026-08-16
- Parcel
- 12217297D
- Built
- 1986 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-2
- Assessor use
- Convenience Store With Fuel Dispensing
- Parcel size
- 0.34 acres
- Building area
- 2,400 sq ft (assessor record)
- Sewer
- Connection on file (2009) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- A 2021 permit was issued; completion is not confirmed in the available record; the permit description states “Upgrade electrical to 800Amp, 3ph, 120/208V” — an increase in capacity as described, not a confirmed installed rating.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionPermitted — completion not confirmedA 2021 permit specifies this work (the permit description states “Upgrade electrical to 800Amp, 3ph, 120/208V”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Inspections. City inspection record: COT - LCEL - Electrical Final approved 2025-01-14. T21CM03323 — Upgrade electrical to 800Amp, 3ph, 120/208V
- Heating, cooling & mechanicalPermitted — completion not confirmedA 2010 permit specifies this work (the permit description states “REPLACE: TWO; 5 TON HEAT PUMPS; CIRCLE K; (APA)”), but the available record does not show a final inspection. The permit expired without a confirmed final status. Official status: Expired. Contractor of record: CONTEMPORARY REFRIGERATION INC *APA*. T10ME00712 — REPLACE: TWO; 5 TON HEAT PUMPS; CIRCLE K; (APA)
- Fire alarm & life safetyCurrentLast permitted 2024 (2 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-1124-00948 — Installation of CO2 monitoring system
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Worth looking at
There is an open code enforcement case on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
A pool or spa was permitted in 2020. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.
Most recent permit on record for this parcel: 2026-06-04 (TC-FBB-0626-00071) — CIRCLE K - SHIPPING CONTAINER (No utilities work such as electrical).
Permit history (27)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-06-04 | TC-FBB-0626-00071City permit record | Factory Built BuildingsCIRCLE K - SHIPPING CONTAINER (No utilities work such as electrical) | Needs resubmittal | |
| 2025-10-08 | TC-COM-1025-01831City permit record | Commercial BuildingPermit for existing 20 foot shipping container used as storage on site | Expired | |
| 2024-11-11finaled | TF-FCP-1124-00948City permit record | Fire ConstructionInstallation of CO2 monitoring system | Complete | |
| 2024-11-11finaled | TF-FOP-1124-01305City permit record | Fire OperationalInstallation of CO2 monitoring system | Complete | |
| 2024-05-29expired 2025-10-11 | TC-COM-0524-01036City permit record | Commercial BuildingRelocating, upgrading and adding equipment into and open and operating convenience store. | Issued | |
| 2021-04-20expired 2025-07-14 | T21CM03323City permit record | Commercial BuildingUpgrade electrical to 800Amp, 3ph, 120/208V | Inspections | |
| 2020-12-18finaled | T20RW06535City permit record | Pool / spaREMOVE AND REPLACE EXISTING BROKEN 13' SIDEWALK AND DRIVEWAY APRON ON NORTH SIDE OF E SPEEDWAY BL JUST WEST OF N CAMILLA BLVD. NOTICE OF VIOLATION #T20DV05317 REVIEW NOTES: BUS STOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-206-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 24-HOURS PRIOR TO START OF WORK FOR COORDINATION. PLACE "BUSINESS ACCESS" SIGNS APPROPRIATELY. SEVERAL BUSINESSES ALONG ROUTE. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. PAVEMENT PATCHING IS NECESSARY WHERE PAVEMENT IS CUT. PATCH LIMITS- THE LIMITS OF THE PAVING SHALL BE A MINIMUM OF 1-FT OUTSIDE THE EXCAVATION. POTHOLES SPACED CLOSELY TOGETHER AND WITHIN 8-FT OF EACH OTHER WILL NEED TO BE JOINED TOGETHER BY ONE SURFACE PATCH. BACKFILL WITH CLSM SLURRY OR AGGREGATE BASE COURSE (ABC.) ASPHALTIC CONCRETE USED SHALL BE CITY OF TUCSON MIX NO. 3 OR COT MIX NO. 2 WITH TR-22, INSPECTOR TO ADVISE. REPLACE/ REFRESH ALL STRIPING THAT IS INTERRUPTED BY PATCHES. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. MAINTAIN PEDESTRIAN ACCESS MAINTAIN ACCESS TO BUS STOPS AND FOR PEDESTRIAN INGRESS/ EGRESS. | Final | |
| 2020-05-19finaled | T20RW02862City permit record | ROWFrom Pole NE of 3155 E Speedway Blvd, riser down pole and head S. Begin 10' trench/bore placing 2-2" conduit. Head W and continue 12' trench/bore placing 2-2" conduit in to out of ROW. | Final |
Show 19 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2018-04-10finaled | T18FC00296City permit record | FIRECONSINSTALL NEW SPILL CONTAINMENT BOXES ON (2) UNDERGROUND FUEL STORAGE TANKS. | Final | |
| 2018-02-22expired 2018-10-07 | T18CM01393City permit record | COMBORELINE FUEL PUMPS | Expired | |
| 2018-02-20finaled | T18FC00160City permit record | FIRECONSRE-LINE (2) UNDER GROUND FUEL STORAGE TANKS | Final | |
| 2017-11-14finaled | T17OT01185City permit record | Fence / wall3 ILLUM WALL SIGNS + 1 CH of C on NON CONF MONU SIGN | Final | |
| 2017-08-21finaled | T17FO00696City permit record | FIREOPERLIST OF FUEL TANKS & PRODUCT | Final | |
| 2017-06-28finaled | T17FO00571City permit record | FIREOPERCARBON DIOXIDE DECTENTION SYSTEM INSTALLATION STORE#2939 | Final | |
| 2017-02-08expired 2017-11-18 | T17CM01033City permit record | COMBOTI: CIRCLE K | Expired | |
| 2016-05-25expired 2016-12-19 | T16CM03916City permit record | COMBOREPL OUTDOOR LIGHTING FIXTURES | Expired | |
| 2016-01-20finaled | T16BU00087City permit record | TANKSREPLACE ( 2 ) FUEL DISPENSERS | Final | |
| 2011-01-18finaled | T11BU00066City permit record | DEMOBILLBOARD; REMOVAL | Final | |
| 2010-12-10expired 2011-12-05 | T10ME00712City permit record | MECHREPLACE: TWO; 5 TON HEAT PUMPS; CIRCLE K; (APA) | Expired | |
| 2010-11-01finaled | T10OT02352City permit record | SIGNCHANGE OF COPY 19078 | Final | |
| 2007-03-22finaled | T07PL00526City permit record | Addition / alterationADDITION: HAND WASH SINK PER PIMA CO. HEALTH DEPT. | Final | |
| 2006-04-27 | T06CM02527City permit record | COMBOREPL: LIGHT FIXTURES FOR BILLBOARD | Withdrwn | |
| 2004-08-10finaled | T04OT01587City permit record | SIGNSIGN:7581 | Final | |
| 1999-12-13finaled | T99PL02660City permit record | PLUMBSEWER LINE:REPAIR | Final | |
| 1999-01-20finaled | T99BU00119City permit record | Fence / wallWALL:40LF OF 6HIGH | Final | |
| 1999-01-19 | T99BU00096City permit record | BUILDTRASH ENCLOSURE | Void | |
| 1997-05-06finaled | T97ME00111City permit record | MECHMECH (2)3HP:(2)5TON AC | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (8)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2025-09-02 | CE-VIO0925-03741Code enforcement case | Work without permit | Active |
| 2020-08-05 | T20DV05317Code enforcement case | Code enforcement case | Complian |
| 2018-12-28 | T18DV08253Code enforcement case | Code enforcement case | Complian |
| 2014-09-24 | T14DV07908Code enforcement case | Code enforcement case | Noverify |
| 2011-03-21 | T11FR00661Code enforcement case | Code enforcement case | Field |
| 2011-03-21finaled | T11FR00662Code enforcement case | Code enforcement case | Complete |
| 2011-01-20finaled | T11FR00202Code enforcement case | Code enforcement case | Complete |
| 2010-01-27finaled | T10FR00203Code enforcement case | Code enforcement case | Complete |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Send: the permanent link and the summary above, once. Watch: one email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list either way.
How this report was built
This is a reading of public records for parcel 12217297D — 27 permits on file from 1997 to 2026 (4 combo, 3 commercial building, 2 firecons, 2 fence / wall) and 8 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.