Electrical permit history — 3155 E Speedway Bl

3155 E Speedway Bl, Tucson — built 1986, with 27 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

3155 E Speedway Bl

Built 1986 — 1980s commercial stock · last permitted panel/service work 2021 (permitted, completion not confirmed) · HVAC 2010 (permit expired without a confirmed final) · 1 open code case

Parcel
12217297D
Built
1986 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Convenience Store With Fuel Dispensing
Parcel size
0.34 acres
Building area
2,400 sq ft (assessor record)
Sewer
Connection on file (2009) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
A 2021 permit was issued; completion is not confirmed in the available record; the permit description states “Upgrade electrical to 800Amp, 3ph, 120/208V” — an increase in capacity as described, not a confirmed installed rating.

See the property

County aerial photograph centered on 3155 E Speedway Bl, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionPermitted — completion not confirmedA 2021 permit specifies this work (the permit description states “Upgrade electrical to 800Amp, 3ph, 120/208V”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Inspections. City inspection record: COT - LCEL - Electrical Final approved 2025-01-14. T21CM03323 — Upgrade electrical to 800Amp, 3ph, 120/208V
  • Heating, cooling & mechanicalPermitted — completion not confirmedA 2010 permit specifies this work (the permit description states “REPLACE: TWO; 5 TON HEAT PUMPS; CIRCLE K; (APA)”), but the available record does not show a final inspection. The permit expired without a confirmed final status. Official status: Expired. Contractor of record: CONTEMPORARY REFRIGERATION INC *APA*. T10ME00712 — REPLACE: TWO; 5 TON HEAT PUMPS; CIRCLE K; (APA)
  • Fire alarm & life safetyCurrentLast permitted 2024 (2 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-1124-00948 — Installation of CO2 monitoring system
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth looking at

    There is an open code enforcement case on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2020. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

Most recent permit on record for this parcel: 2026-06-04 (TC-FBB-0626-00071) — CIRCLE K - SHIPPING CONTAINER (No utilities work such as electrical).

Permit history (27)

Permit history for this parcel — 8 of 27 records
DateRecordWhatStatusValue
2026-06-04TC-FBB-0626-00071City permit recordFactory Built BuildingsCIRCLE K - SHIPPING CONTAINER (No utilities work such as electrical)Needs resubmittal
2025-10-08TC-COM-1025-01831City permit recordCommercial BuildingPermit for existing 20 foot shipping container used as storage on siteExpired
2024-11-11finaledTF-FCP-1124-00948City permit recordFire ConstructionInstallation of CO2 monitoring systemComplete
2024-11-11finaledTF-FOP-1124-01305City permit recordFire OperationalInstallation of CO2 monitoring systemComplete
2024-05-29expired 2025-10-11TC-COM-0524-01036City permit recordCommercial BuildingRelocating, upgrading and adding equipment into and open and operating convenience store.Issued
2021-04-20expired 2025-07-14T21CM03323City permit recordCommercial BuildingUpgrade electrical to 800Amp, 3ph, 120/208VInspections
2020-12-18finaledT20RW06535City permit recordPool / spaREMOVE AND REPLACE EXISTING BROKEN 13' SIDEWALK AND DRIVEWAY APRON ON NORTH SIDE OF E SPEEDWAY BL JUST WEST OF N CAMILLA BLVD. NOTICE OF VIOLATION #T20DV05317 REVIEW NOTES: BUS STOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-206-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 24-HOURS PRIOR TO START OF WORK FOR COORDINATION. PLACE "BUSINESS ACCESS" SIGNS APPROPRIATELY. SEVERAL BUSINESSES ALONG ROUTE. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. PAVEMENT PATCHING IS NECESSARY WHERE PAVEMENT IS CUT. PATCH LIMITS- THE LIMITS OF THE PAVING SHALL BE A MINIMUM OF 1-FT OUTSIDE THE EXCAVATION. POTHOLES SPACED CLOSELY TOGETHER AND WITHIN 8-FT OF EACH OTHER WILL NEED TO BE JOINED TOGETHER BY ONE SURFACE PATCH. BACKFILL WITH CLSM SLURRY OR AGGREGATE BASE COURSE (ABC.) ASPHALTIC CONCRETE USED SHALL BE CITY OF TUCSON MIX NO. 3 OR COT MIX NO. 2 WITH TR-22, INSPECTOR TO ADVISE. REPLACE/ REFRESH ALL STRIPING THAT IS INTERRUPTED BY PATCHES. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. MAINTAIN PEDESTRIAN ACCESS MAINTAIN ACCESS TO BUS STOPS AND FOR PEDESTRIAN INGRESS/ EGRESS.Final
2020-05-19finaledT20RW02862City permit recordROWFrom Pole NE of 3155 E Speedway Blvd, riser down pole and head S. Begin 10' trench/bore placing 2-2" conduit. Head W and continue 12' trench/bore placing 2-2" conduit in to out of ROW.Final
Show 19 older records
Permit history for this parcel — remaining 19 records
DateRecordWhatStatusValue
2018-04-10finaledT18FC00296City permit recordFIRECONSINSTALL NEW SPILL CONTAINMENT BOXES ON (2) UNDERGROUND FUEL STORAGE TANKS.Final
2018-02-22expired 2018-10-07T18CM01393City permit recordCOMBORELINE FUEL PUMPSExpired
2018-02-20finaledT18FC00160City permit recordFIRECONSRE-LINE (2) UNDER GROUND FUEL STORAGE TANKSFinal
2017-11-14finaledT17OT01185City permit recordFence / wall3 ILLUM WALL SIGNS + 1 CH of C on NON CONF MONU SIGNFinal
2017-08-21finaledT17FO00696City permit recordFIREOPERLIST OF FUEL TANKS & PRODUCTFinal
2017-06-28finaledT17FO00571City permit recordFIREOPERCARBON DIOXIDE DECTENTION SYSTEM INSTALLATION STORE#2939Final
2017-02-08expired 2017-11-18T17CM01033City permit recordCOMBOTI: CIRCLE KExpired
2016-05-25expired 2016-12-19T16CM03916City permit recordCOMBOREPL OUTDOOR LIGHTING FIXTURESExpired
2016-01-20finaledT16BU00087City permit recordTANKSREPLACE ( 2 ) FUEL DISPENSERSFinal
2011-01-18finaledT11BU00066City permit recordDEMOBILLBOARD; REMOVALFinal
2010-12-10expired 2011-12-05T10ME00712City permit recordMECHREPLACE: TWO; 5 TON HEAT PUMPS; CIRCLE K; (APA)Expired
2010-11-01finaledT10OT02352City permit recordSIGNCHANGE OF COPY 19078Final
2007-03-22finaledT07PL00526City permit recordAddition / alterationADDITION: HAND WASH SINK PER PIMA CO. HEALTH DEPT.Final
2006-04-27T06CM02527City permit recordCOMBOREPL: LIGHT FIXTURES FOR BILLBOARDWithdrwn
2004-08-10finaledT04OT01587City permit recordSIGNSIGN:7581Final
1999-12-13finaledT99PL02660City permit recordPLUMBSEWER LINE:REPAIRFinal
1999-01-20finaledT99BU00119City permit recordFence / wallWALL:40LF OF 6HIGHFinal
1999-01-19T99BU00096City permit recordBUILDTRASH ENCLOSUREVoid
1997-05-06finaledT97ME00111City permit recordMECHMECH (2)3HP:(2)5TON ACFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (8)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 8 records
DateRecordWhatStatus
2025-09-02CE-VIO0925-03741Code enforcement caseWork without permitActive
2020-08-05T20DV05317Code enforcement caseCode enforcement caseComplian
2018-12-28T18DV08253Code enforcement caseCode enforcement caseComplian
2014-09-24T14DV07908Code enforcement caseCode enforcement caseNoverify
2011-03-21T11FR00661Code enforcement caseCode enforcement caseField
2011-03-21finaledT11FR00662Code enforcement caseCode enforcement caseComplete
2011-01-20finaledT11FR00202Code enforcement caseCode enforcement caseComplete
2010-01-27finaledT10FR00203Code enforcement caseCode enforcement caseComplete

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 12217297D — 27 permits on file from 1997 to 2026 (4 combo, 3 commercial building, 2 firecons, 2 fence / wall) and 8 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.