Electrical permit history — 3459 E Speedway Bl

3459 E Speedway Bl, Tucson — built 1979, with 49 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

3459 E Speedway Bl

Built 1979 — 1970s commercial stock · HVAC 2004 (finaled)

Parcel
12217002B
Built
1979 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Retail Strip Center
Parcel size
0.79 acres
Building area
11,461 sq ft (assessor record)
Sewer
Connection on file (1952) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 3459 E Speedway Bl, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2016 build permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalLikely dueLast permitted 2004 (22 years ago). City inspection record: PERMIT FINALED approved 2004-08-20. Contractor of record: AIR CONDITIONING ASSOCIATES INC *C. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Equipment from before about 2010 generally runs R-22, which has not been produced since 2020 — repairs mean reclaimed refrigerant at a price that often exceeds replacing the unit. T04ME00558 — REPLACE:SPLIT SYSTEM (APA)
  • Fire alarm & life safetyCurrentLast permitted 2019 (7 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T19FC00546 — *** NO PLANS *** TI - Relocate 5
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2025. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Worth confirming

    There is an electrical reconnect permit from 2012. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2022-12-15$2,980,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2025-05-19 (SP-NRP-0525-00280) — *Complete - Added to Utility Clearance Report* - - We need to schedule an inspection with the city ASAP in order to get electricity turned on the suite, for the purpose of preparing the space to be ready for showing prospective commercial tenants. Please let us know if you need anything else. Thank you! - -.

Permit history (49)

Permit history for this parcel — 8 of 49 records
DateRecordWhatStatusValue
2025-05-19finaledSP-NRP-0525-00280City permit recordPool / spa*Complete - Added to Utility Clearance Report* - - We need to schedule an inspection with the city ASAP in order to get electricity turned on the suite, for the purpose of preparing the space to be ready for showing prospective commercial tenants. Please let us know if you need anything else. Thank you! - -Complete
2025-05-16expired 2025-06-15SP-NRP-0525-00278City permit recordPool / spaWe have submitted a permit application at commercial building 3447-3449 E Speedway Blvd at 2400 sqft. We need to schedule an inspection with the city ASAP in order to get electricity turned on the suite, for the purpose of preparing the space to be ready for showing prospective commercial tenants. Please let us know if you need anything else. Thank you!Inspections
2025-05-05TC-COM-0525-00904City permit recordElectrical reconnectVOID – WRONG WORK CLASS When you make your next application, please apply for a separate permit per address. Please check the descriptions before reapplying to confirm you are utilizing the right permit application. Electrical Reconnect Only: All property types: Residential, Commercial, Mixed Use, etc. Application for Residential or Commercial Electrical Reconnects ONLY for reconnection of occupiable buildings after a period of depowered status. *This is a non-refundable permit.* DO NOT Apply for this permit for the following: **New electrical equipment or repairs ** **New or existing construction/structural activity** **Work related to a Code Enforcement case** (For electrical upgrades/installations or other trade activity, please use the "Trade" permit associated to your property type) (For reconnects requiring/including any structural construction work, please use the "Additions/Alterations" permit associated to your property type) (For reconnects related to a Code Violation, an "Additions/Alterations" permit associated to your property type is required for completing related work) (For reconnects related to a structure requiring Fire Restoration work, an "Additions/Alterations" permit associated to your property type is required for completing related work) (For new building construction, power/electrical connection is included in the inspections of the associated building permit) We need electricity turned on in order to prepare the suite to be ready to show to prospective tenants.Void
2025-03-04finaledTC-COM-0325-00423City permit recordCommercial BuildingSmoke shop C of OComplete
2025-02-06TS-PRM-0225-00050City permit recordSign - PermanentStore sign to be located on top of storeExpired
2025-01-07finaledSP-NRP-0125-00008City permit recordSimple*Complete - Added to Utility Clearance Report* - - Starting a new business for party supplies sell - -Complete
2021-09-16finaledT21OT00685City permit recordFence / wall1-illum wall signComplete
2021-07-29finaledT21RW03560City permit recordROWSE Corner of Jones BLVD and E Cody ST Head E 495' overlashing 288ct Fiber. Head S 20’ continuing aerial overlash 48ct fiber in to out of ROW. Proof of notification is required at the time of the preconstruction meeting. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. ALL AERIAL WORK MUST BE A MINIMUM OF 16-FT HIGH. AND MUST BE A MINIMUM OF 18-FT HIGH WHEN CROSSING INTERSECTIONS, PAVEMENT AND ALLEYS. MAINTAIN PEDESTRIAN ACCESSFinal

41 older records are not shown here. — each links to its official file.

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (40)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 40 records
DateRecordWhatStatus
2018-06-26T18DV03700Code enforcement caseCode enforcement caseComplian
2017-12-11T17DV06578Code enforcement caseGraffitiNoverify
2016-06-27T16DV03859Code enforcement caseCode enforcement caseComplian
2015-09-28T15DV07165Code enforcement caseCode enforcement caseNoverify
2015-09-09T15DV06553Code enforcement caseCode enforcement caseComplian
2015-08-19T15DV06066Code enforcement caseVegetationComplian
2014-07-03T14DV04479Code enforcement caseCode enforcement caseNoverify
2014-06-19T14DV04060Code enforcement caseCode enforcement caseComplian
Show 32 older records
Code enforcement history for this parcel — remaining 32 records
DateRecordWhatStatus
2012-12-07T12DV10980Code enforcement caseCode enforcement caseComplian
2012-10-05T12DV09394Code enforcement caseSignNoverify
2012-07-26T12DV06246Code enforcement caseCode enforcement caseComplian
2012-06-14T12DV04975Code enforcement caseCode enforcement caseComplian
2012-06-11T12DV04887Code enforcement caseSignComplian
2011-08-05T11DV06293Code enforcement caseRefuseNoverify
2011-05-25T11DV03811Code enforcement caseWork without permitComplian
2011-05-25T11DV03813Code enforcement caseWork without permitComplian
2011-05-25T11DV03816Code enforcement caseWork without permitComplian
2011-01-03finaledT11FR00007Code enforcement caseCode enforcement caseComplete
2009-12-23finaledT09FR03860Code enforcement caseCode enforcement caseComplete
2009-12-18finaledT09FR03824Code enforcement caseCode enforcement caseComplete
2009-05-06T09DV02569Code enforcement caseVegetationNoverify
2009-02-20finaledT09FR00715Code enforcement caseCode enforcement caseComplete
2008-10-27T08DV10129Code enforcement caseCode enforcement caseNoverify
2008-09-29finaledT08FR03255Code enforcement caseCode enforcement caseComplete
2008-07-17finaledT08FR01975Code enforcement caseCode enforcement caseComplete
2008-01-29T08DV00808Code enforcement caseSignComplian
2007-10-09finaledT07FR02030Code enforcement caseCode enforcement caseComplete
2007-06-12finaledT07FR01123Code enforcement caseFireComplete
2007-05-29finaledT07FR01028Code enforcement caseFireComplete
2006-12-21T06DV03201Code enforcement caseCode enforcement caseCancel
2006-06-08finaledT06FR01860Code enforcement caseCode enforcement caseComplete
2006-03-14finaledT06FR00356Code enforcement caseCode enforcement caseComplete
2005-11-16T05ZV00647Code enforcement caseCode enforcement caseComplian
2005-03-17T05FR00387Code enforcement caseCode enforcement caseField
2005-03-16finaledT05FR00382Code enforcement caseCode enforcement caseComplete
2005-03-16T05FR00383Code enforcement caseCode enforcement caseField
2004-02-23T04VL00084Code enforcement caseSignComplian
2004-01-06T04ZV00006Code enforcement caseCode enforcement caseInvalid
1999-02-24T99VL00534Code enforcement caseSignComplian
1998-08-27T98VL00648Code enforcement caseSignComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 12217002B — 49 permits on file from 1997 to 2025 (8 combo, 7 sign, 7 c-of-o, 6 fence / wall) and 40 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.