Electrical permit history — 3201 E Seneca St

3201 E Seneca St, Tucson — built 1972, with 31 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Multifamily property

3201 E Seneca St

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1972 — 1970s multifamily stock · 31 permits on record; no permitted panel/service or HVAC work among them

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Nothing permitted on the service or distribution shows in the record we read, which for a building of this era leaves the original switchgear generation in play. Obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown — worth establishing what is actually installed before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Composition Shingle. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Routine

    A trade permit was pulled in 2022. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 81,906 sq ft (county building-footprint layer, 19 structures)
Usable for solar, planning estimate
≈ 57,300 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 630 kW — roughly 1,580 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 1,040,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$83,000–$135,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “El Con Mall - Reid Park Area”, is about 1.4 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
12215015C
Year constructed
1972 (assessor record)
Permitting authority
Tucson
Zoning
R-3
Property type
Apartments 100+ Units 2 Story
Building area
142,270 sq ft

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 31 building permits for this parcel dated between 1999 and 2025. By category the work is addition / alteration (7), floodplain use (6), zoning compliance (5) and trade permit (4). 17 of them carry a final inspection; the other 14 were issued, expired or are still open, which is not the same as work completed. There are 111 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 12215015C. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All multifamily property · Commercial property in 85716 · Commercial & industrial reports · Homes in 85716 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on E SENECA ST hold 529 City permits on record, 173 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (142 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2025CE-VIO0925-04240Code enforcement caseClosed - Resolved
2025recordROW Permit - City CIP/JOCComplete
2024TC-COM-0624-01212Commercial Addition/Alteration PermitInspections Complete
2024TC-COM-0624-01211Commercial Addition/Alteration PermitInspections Complete
2024TC-COM-0524-00992Commercial Addition/Alteration PermitIssued
2024TC-COM-0624-01209Commercial Addition/Alteration PermitInspections Complete
2024TC-COM-0624-01210Commercial Addition/Alteration PermitInspections Complete
2024TE-FPU-0824-00218Floodplain Use PermitIssued
2024TE-FPU-0824-00223Floodplain Use PermitIssued
2024TE-FPU-0824-00225Floodplain Use PermitIssued
2024TE-FPU-0824-00226Floodplain Use PermitIssued
2024TE-FPU-0824-00224Floodplain Use PermitIssued
2024CE-VIO0824-03081ElectricalClosed - Unfounded
2024recordROW Permit - City CIP/JOCNeeds Resubmittal
2024CE-VIO0224-00746Code enforcement caseClosed - Resolved
2024CE-VIO0224-00598Code enforcement caseClosed - Unfounded
2024CE-VIO0124-00168Code enforcement caseClosed - Resolved
2023CE-VIO0723-04620Code enforcement caseClosed - Unfounded
2023CE-VIO0723-04619Code enforcement caseClosed - Resolved
2023CE-VIO0723-04593Code enforcement caseClosed - Resolved
2023CE-VIO0723-04559Code enforcement caseClosed - Unfounded
2023CE-VIO0623-04014Code enforcement caseClosed - Resolved
2023TC-COM-0523-01313Commercial Addition/Alteration PermitWithdrawn
2023CE-VIO0423-02748Code enforcement caseClosed - Resolved
2023CE-VIO0323-02654Code enforcement caseClosed - Resolved
2023CE-VIO0323-02485Code enforcement caseClosed - Resolved
2023CE-VIO0323-02202ElectricalClosed - Resolved
2023CE-VIO0123-01245Code enforcement caseClosed - Unfounded
2022T22CM04651Commercial Trade PermitComplete
2022CE-VIO1222-00831Code enforcement caseClosed - Resolved
2022CE-VIO1122-00162Code enforcement caseClosed - Resolved
2022T22DV06035FireClosed - Resolved
2022T22DV06036FireClosed - Resolved
2022T22DV06037FireClosed - Resolved
2022T22DV04717RES: MINIMUM HOUSINGCOMPLIAN
2022T22DV03657RES: MINIMUM HOUSINGCOMPLIAN
2022T22DV03646RES: MINIMUM HOUSINGCOMPLIAN
2022T22SA00234Zoning ComplianceComplete
2022T22CM02188Commercial Trade PermitExpired
2022T22DV01896EMERGENCYCOMPLIAN
2022T22DV01907EMERGENCYCOMPLIAN
2021T21DV08077RES: MINIMUM HOUSINGNOVERIFY
2021T21DV06030RES: MINIMUM HOUSINGCOMPLIAN
2021T21DV06004LIGHTING VIOLATIONREFERRED
2021T21DV05855RES: MINIMUM HOUSINGCOMPLIAN
2021T21DV05551RES: MINIMUM HOUSINGCOMPLIAN
2021T21DV05375RES: MINIMUM HOUSINGCOMPLIAN
2021T21DV05382RES: MINIMUM HOUSINGCOMPLIAN
2021T21DV05151RES: MINIMUM HOUSINGCOMPLIAN
2021T21DV04672RES: MINIMUM HOUSINGCOMPLIAN
2021T21DV04339RES: MINIMUM HOUSINGCOMPLIAN
2021T21DV04120RES: MINIMUM HOUSINGNOVERIFY
2021T21DV03846RES: MINIMUM HOUSINGNOVERIFY
2021T21DV03866RES: MINIMUM HOUSINGCOMPLIAN
2021T21DV03817RES: MINIMUM HOUSINGNOVERIFY
2021T21DV03827RES: MINIMUM HOUSINGCOMPLIAN
2021T21DV03782RES: MINIMUM HOUSINGREFERRED
2021T21DV03647RES: MINIMUM HOUSINGFIELD
2021T21DV03645RES: MINIMUM HOUSINGCOMPLIAN
2021T21DV03165RES: MINIMUM HOUSINGCOMPLIAN
2021T21CM02727Commercial Trade PermitComplete
2021T21CM03657Commercial Trade PermitComplete
2020T20SA00364Zoning ComplianceComplete
2020T20DV05973RES: MINIMUM HOUSINGCOMPLIAN
2020T20DV02009ANIMAL WASTENOVERIFY
2020T20DV00597RES: MINIMUM HOUSINGNOVERIFY
2019T19DV08428ANIMAL WASTEREFERRED
2019T19DV08311RESIDENTIAL ZONINGNOVERIFY
2019T19DV07124MULTIPLE TYPESCOMPLIAN
2019T19DV05621RES: MINIMUM HOUSINGNOVERIFY
2019T19DV05186RES: MINIMUM HOUSINGNOVERIFY
2019T19DV05170JUNK MOTOR VEHICLESPENDING
2019T19DV03610RES: MINIMUM HOUSINGCANCEL
2019T19DV03611RES: MINIMUM HOUSINGCANCEL
2018T18DV08060PROP MAINT MULTIPLE TYPESNOVERIFY
2018T18DV07893RES: MINIMUM HOUSINGNOVERIFY
2018T18DV07279RES: MINIMUM HOUSINGNOVERIFY
2018T18DV06657PROP MAINT MULTIPLE TYPESNOVERIFY
2018T18DV04045COMMERCIAL ZONINGCOMPLIAN
2018T18OT00617Annual Portable Sign ComplianceComplete
2018T18DV03054RES: MINIMUM HOUSINGCOMPLIAN
2018T18SA00216Zoning ComplianceComplete
2018T18OT00259Annual Portable Sign ComplianceCanceled
2018T18DV00622RES: MINIMUM HOUSINGCOMPLIAN
2017T17DV06773RES: MINIMUM HOUSINGCOMPLIAN
2017T17SA00480Zoning ComplianceComplete
2017T17OT01260Annual Portable Sign ComplianceCanceled
2017T17DV05860RES: MINIMUM HOUSINGCOMPLIAN
2017T17DV05867RES: MINIMUM HOUSINGCOMPLIAN
2017T17DV05259RES: MINIMUM HOUSINGCOMPLIAN
2017T17DV04485RES: MINIMUM HOUSINGCOMPLIAN
2017T17DV04272PROP MAINT MULTIPLE TYPESNOVERIFY
2017T17DV03549EMERGENCYNOVERIFY
2017T17DV02767RES: MINIMUM HOUSINGNOVERIFY
2017T17DV02685RES: MINIMUM HOUSINGCOMPLIAN
2017T17DV02446MULTIPLE TYPESCOMPLIAN
2017T17DV01957RES: MINIMUM HOUSINGCOMPLIAN
2017T17DV01748RES: MINIMUM HOUSINGCOMPLIAN
2017T17DV01195RES: MINIMUM HOUSINGCOMPLIAN
2017T17DV01100ENVIRONMENTALNOVERIFY
2017T17DV00653RES: MINIMUM HOUSINGNOVERIFY
2017T17DV00589RES: MINIMUM HOUSINGCOMPLIAN
2016T16DV07494RES: MINIMUM HOUSINGCANCEL
2016T16DV06239RES: MINIMUM HOUSINGCOMPLIAN
2016T16DV05473ENVIRONMENTALNOVERIFY
2016T16DV04797RES: MINIMUM HOUSINGCOMPLIAN
2016T16DV04751RES: MINIMUM HOUSINGCOMPLIAN
2016T16DV04547ENVIRONMENTALCOMPLIAN
2016T16DV04503RES: MINIMUM HOUSINGCOMPLIAN
2016T16DV04190RES: MINIMUM HOUSINGCOMPLIAN
2016T16DV04073RES: MINIMUM HOUSINGCOMPLIAN
2016T16DV03998RES: MINIMUM HOUSINGCOMPLIAN
2016T16DV03822RES: MINIMUM HOUSINGCANCEL
2016T16DV03826RES: MINIMUM HOUSINGCOMPLIAN
2016T16DV03673RES: MINIMUM HOUSINGCOMPLIAN
2016T16DV03214CONTAINER VIOLATIONCOMPLIAN
2016T16DV02906RES: MINIMUM HOUSINGNOVERIFY
2016T16DV00646RES: MINIMUM HOUSINGCOMPLIAN
2015T15DV07835MULTIPLE TYPESCOMPLIAN
2015T15DV06503RES: MINIMUM HOUSINGCOMPLIAN
2015T15DV01778RES: MINIMUM HOUSINGCOMPLIAN
2015T15DV00714RES: MINIMUM HOUSINGCOMPLIAN
2014T14DV07826RES: MINIMUM HOUSINGCOMPLIAN
2014T14DV06006RES: MINIMUM HOUSINGCOMPLIAN
2014T14DV05622RES: MINIMUM HOUSINGCOMPLIAN
2013T13DV06314RES: MINIMUM HOUSINGCOMPLIAN
2013T13DV01187MULTIPLE TYPESNOVERIFY
2011T11DV00178RES: MINIMUM HOUSINGNOVERIFY
2009T09DV05510RES: MINIMUM HOUSINGNOVERIFY
2009T08OT03018Permanent Sign PermitComplete
2008T08BU02211Commercial Addition/Alteration PermitCanceled
2008T08OT03024Floodplain Use PermitCanceled
2008T08DV11400RES: MINIMUM HOUSINGCOMPLIAN
2008T08SA00390Zoning ComplianceComplete
2008T08DV09390RES: MINIMUM HOUSINGNOVERIFY
2008T08DV07846RES: MINIMUM HOUSINGNOVERIFY
2008T08DV07154RES: MINIMUM HOUSINGCOMPLIAN
2008T08DV06554RES: MINIMUM HOUSINGCOMPLIAN
2008T08OT01272Peddler PermitCanceled
2008T08DV00285ILLEGAL DUMPINGNOVERIFY
2005T05VL00573Permanent Sign PermitComplete
1999T99VL02794Permanent Sign PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 12215015C — 31 City permits on file from 1999 to 2025 and 111 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area, roof, walls on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.