Electrical permit history — 1423 N Venice Av

1423 N Venice Av, Tucson — built 1963, with 23 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Multifamily property

1423 N Venice Av

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1963 — 1960s multifamily stock · last permitted panel/service work 2025 (finaled) · HVAC 2015 (finaled)

Is it time to upgrade?

  • Electrical service & distributionFinaled permit foundLast permitted 2025 (1 year ago). Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. TC-COM-0925-01707 — Install 125 amp 3r main breaker house panel on south side of building M fed from meter two pack mounted just to south with 1 1/2 pvc 1/0 xhhw #6 ground.
  • Heating, cooling & mechanicalFinaled permit foundLast permitted 2015 (11 years ago). The assessor records cooling as WARMED AND COOLED AIR and heating as Forced Air. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T15CM03267 — NEW MINI SPLIT SYSTEM FOR APARTMENT
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Composition Shingle. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    A finaled 2025 panel/service permit is on record for this parcel, which makes it unlikely the original 60–100 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2015. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Routine

    A trade permit was pulled in 2025. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 13,513 sq ft (county building-footprint layer, 5 structures)
Usable for solar, planning estimate
≈ 9,500 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 105 kW — roughly 260 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 170,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$14,000–$22,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “El Con Mall - Reid Park Area”, is about 1 mile away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
12212184A
Year constructed
1963 (assessor record)
Permitting authority
Tucson
Zoning
R-2
Property type
Apartments 5 - 24 Units 1 Story
Building area
8,658 sq ft
Cooling
WARMED AND COOLED AIR
Heating
Forced Air
Service on record
City records show the 2025 permit was finalized; the permit description states “Install 125 amp 3r main breaker house panel on south side of building M fed from meter two pack mounted just to south with 1 1/2 pvc 1/0 xhhw #6 ground.”.

The building area, cooling and heating above come from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 23 building permits for this parcel dated between 1997 and 2025. By category the work is trade permit (22) and demolition. 15 of them carry a final inspection; the other 8 were issued, expired or are still open, which is not the same as work completed. There are 14 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 12212184A. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All multifamily property · Commercial property in 85712 · Commercial & industrial reports · Homes in 85712 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on N VENICE AV hold 236 City permits on record, 57 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (37 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2025TC-COM-0925-01707Commercial Trade PermitComplete
2025CE-VIO1125-05154Code enforcement caseClosed - Unfounded
2025TC-COM-0925-01687Commercial Trade PermitInspections
2025TC-COM-0525-01065Commercial Trade PermitComplete
2025TC-COM-0525-01066Commercial Trade PermitInspections
2025CE-VIO0525-02176Code enforcement caseClosed - Resolved
2025TC-COM-0525-00940Commercial Trade PermitExpired
2025TC-COM-0325-00492Commercial Trade PermitInspections
2025TC-COM-0325-00415Commercial Trade PermitInspections
2023CE-VIO0823-04992FireClosed - Unfounded
2023CE-VIO0423-03060Code enforcement caseClosed - Unfounded
2021T21DV07176MULTIPLE TYPESNOVERIFY
2020T20DV03872PROP MAINT MULTIPLE TYPESCOMPLIAN
2020T20DV01215WEEDSREFERRED
2018T18DV06796REFUSECOMPLIAN
2018T18DV02552REFUSECOMPLIAN
2016T16DV07757RES: MINIMUM HOUSINGCOMPLIAN
2015T15CM03335Commercial Trade PermitComplete
2015T15CM03267Commercial Trade PermitComplete
2015T15CM03268Commercial Trade PermitComplete
2015T15CM03266Commercial Trade PermitWithdrawn
2015T15CM03120Commercial Trade PermitComplete
2015T15CM02934Commercial Trade PermitComplete
2015T15CM02848Commercial Trade PermitComplete
2015T15BU00378Commercial DemolitionCanceled
2015T15DV01649REFUSENOVERIFY
2014T14DV07447REFUSECOMPLIAN
2013T13CM07631Commercial Trade PermitCanceled
2012T12CM04269Commercial Trade PermitComplete
2011T11DV02723JUNK MOTOR VEHICLESNOVERIFY
2009T09PL00316Commercial Trade PermitComplete
2009T09EL00246Commercial Trade PermitComplete
2009T09PL00238Residential Trade PermitComplete
2009T09DV00624RES: MINIMUM HOUSINGCOMPLIAN
2000T00PL01800Commercial Trade PermitComplete
1998T98PL02304Residential Trade PermitComplete
1997T97EL01893Commercial Trade PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 12212184A — 23 City permits on file from 1997 to 2025 and 14 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area, cooling, heating, roof, walls on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-08-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.