Electrical permit history — 1423 N Venice Av
1423 N Venice Av, Tucson — built 1963, with 29 permits on record. Review electrical, HVAC and remodel history with links to official records.
Multifamily property
1423 N Venice Av
Built 1963 — 1960s multifamily stock · last permitted panel/service work 2025 (finaled) · HVAC 2015 (finaled)
Permanent link: Electrical permit history for 1423 N Venice Av (aztucsonelectricalsolutions.com/property/12212184a/1423-n-venice-av-tucson-az-85712) · Public records last checked 2026-08-17
- Parcel
- 12212184A
- Built
- 1963 (county record)
- Jurisdiction
- Tucson
- Zoning
- R-2
- Assessor use
- Apartments 5 - 24 Units 1 Story
- Parcel size
- 0.82 acres
- Building area
- 8,658 sq ft (assessor record)
- Sewer
- Connection on file (1963, 2018) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- City records show the 2025 permit was finalized; the permit description states “Install 125 amp 3r main breaker house panel on south side of building M fed from meter two pack mounted just to south with 1 1/2 pvc 1/0 xhhw #6 ground.”.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionCurrentLast permitted 2025 (1 year ago). City inspection record: COT - LCEL - Electrical Final approved 2026-01-21. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. TC-COM-0925-01707 — Install 125 amp 3r main breaker house panel on south side of building M fed from meter two pack mounted just to south with 1 1/2 pvc 1/0 xhhw #6 ground.
- Heating, cooling & mechanicalCurrentLast permitted 2015 (11 years ago). City inspection record: MECHANICAL - FINAL approved 2017-07-25. Contractor of record: BLOOM'S HEATING AND COOLING,*APA*. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T15CM03267 — NEW MINI SPLIT SYSTEM FOR APARTMENT
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
There is an electrical reconnect permit from 2015. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.
Recorded sales (5)
| Date | Price | Type |
|---|---|---|
| 2024-12-05 | $1,410,000 | Warranty Deed |
| 2020-05-21 | $950,000 | Warranty Deed |
| 2017-06-12 | $728,500 | Warranty Deed |
| 2005-02-28 | $580,000 | Warranty Deed |
| 2000-05-12 | $370,000 | Special Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2025-09-19 (TC-COM-0925-01707) — Install 125 amp 3r main breaker house panel on south side of building M fed from meter two pack mounted just to south with 1 1/2 pvc 1/0 xhhw #6 ground..
Permit history (29)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2025-09-19finaled | TC-COM-0925-01707City permit record | Commercial BuildingInstall 125 amp 3r main breaker house panel on south side of building M fed from meter two pack mounted just to south with 1 1/2 pvc 1/0 xhhw #6 ground. | Complete | |
| 2025-09-17expired 2026-06-22 | TC-COM-0925-01687City permit record | Commercial Buildingpermit is to install electrical to renovated apartment with 125 amp panel. | Inspections | |
| 2025-06-06 | TC-COM-0625-01105City permit record | Commercial BuildingVOIDED DUPLICATE permit is for service upgrade north building. cordinate with TEP demo old 60 amp blade discos and gutter ct. Install new overhead riser. 400 amp meter six pack. new ground rods, gas bond, and 1/0 water bond | Void | |
| 2025-06-06 | TC-COM-0625-01106City permit record | Commercial BuildingVOIDED DUPLICATE PERMIT permit is to demo old 60 amp discos and gutter box. Service upgrade to 400 amp meter six pack and house panel 2 pack. new overhead mast. ground rods, gas and water 1/0 bond. coordination with TEP. | Void | |
| 2025-06-06 | TC-COM-0625-01107City permit record | Commercial BuildingVOIDED DUPLICATE PERMIT permit is for service upgrade north building. coordinate with TEP demo old 60 amp discos and gutter. install new overhead mast 400 amp metered 6 pack. new ground rods, gas bond and 1/0 water bond. | Void | |
| 2025-05-29finaled | TC-COM-0525-01065City permit record | Commercial BuildingService upgrade south building. coordinate with TEP and demo old 60 amp disconnects and gutter CT. Install new 400 amp meter 6 pack with 125 amp feeds for units a-f. New 1/0 water bond and # 4 bare cooper to two new 8 foot ground rods new gas bond. | Complete | |
| 2025-05-29expired 2026-06-02 | TC-COM-0525-01066City permit record | Commercial BuildingService upgrade. Coordinate with TEP demo old 60 amp disconnects, and gutter CT. install new 400 amp met er 6 pack and overhead service. new 1/0 water bond two 8 foot ground rods new #4 bare water bond. | Inspections | |
| 2025-05-08 | TC-COM-0525-00940City permit record | Addition / alterationContinue remodel of existing units a-k. coordinate with TEP demo old 60 amp services install two new six pack meter combos with new risers, and bonds. New two pack meter for house panel and unit M , additional plan and permit to follow for M | Expired |
Show 21 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2025-03-12expired 2026-06-02 | TC-COM-0325-00492City permit record | Fence / wallowner is replacing all overhead and any other damaged drywall. Electrical system is to be evaluated and upgraded per plan. new 100 amp main breaker 16/32 panel with afci protection per 210.12a. new breakers, homeruns, branch and lighting all per plan. when tep plans permits complete. refeed with 1/0 4 wire ser cable. | Inspections | |
| 2025-03-08 | TC-COM-0325-00461City permit record | Commercial Building** VOID: YL - Duplicate/Same scope of work as existing application permit (TC-COM-0325-00415). Please resubmit under existing permit or withdraw existing permit before moving forward with a new application. For questions: Building_Official@tucsonaz.gov Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf ** - Apartment has been demo down to studs and trusses. customer requests replace entire electrical system. new up to modern code. install new 100 amp siemens main breaker 20/40 fed from 60 amp dc switch. Tep evaluation pending for service and feeder upgrade. addendum to follow when complete. | Void | |
| 2025-03-04expired 2026-03-16 | TC-COM-0325-00415City permit record | Commercial Buildingcustomer has removed old corroded failing electrical system. request replacement. New 100 amp main 20 ck panel fed from 60 amp fused disconnect. new boxes, wiring, lighting, and devices. per nec code. | Inspections | |
| 2025-03-03 | TC-COM-0325-00409City permit record | Addition / alterationVOID - WRONG WORK CLASS - Please submit a new application utilizing the Commercial Addition/Alteration Permit Work Class. When re-applying, please remember that this is a Commercial Permit requiring a Complete Set of Plans In accordance with SECTION 107 of the 2018 IBC and the PDSD Building Plan Requirements, a Page 2 of 4 Revised July 12, 2023 complete set of fully dimensioned plans demonstrating the full scope of work shall be provided. All plans must be sealed and signed by an Architect or Engineer registered in the State of Arizona. Note. The term ‘building plans’ may refer to structural, electrical, plumbing, or any other trade regulated by the associated suite of codes adopted by the City of Tucson. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/checklists/commercial_submittal_requirements_july2023.pdf Please feel free to contact me if you have any questions or concerns regarding these comments. Thank you - Doris Benoit 520.633.9084 Doris.Benoit@Tucsonaz.gov Owner request demo of old electrical system APT K. that is corroded and failing. Install new electrical system in APT K and repair replace electrical service addendum to follow when TEP consult complete. Various portions of plumbing sewer are also being repaired. | Void | |
| 2015-05-19finaled | T15CM03335City permit record | COMBOGAS RE-PIPE & WATER HEATER | Final | |
| 2015-05-15 | T15CM03266City permit record | COMBONEW MINI SPLIT SYSTEM FOR APARTMENT | Withdrwn | |
| 2015-05-15finaled | T15CM03267City permit record | COMBONEW MINI SPLIT SYSTEM FOR APARTMENT | Final | |
| 2015-05-15finaled | T15CM03268City permit record | COMBONEW MINI SPLIT SYSTEM FOR APARTMENT | Final | |
| 2015-05-08finaled | T15CM03120City permit record | COMBOREPL GAS LINE | Final | |
| 2015-05-04finaled | T15CM02934City permit record | COMBONEW MINI SPLIT SYSTEM FOR APARTMENT | Final | |
| 2015-04-30finaled | T15CM02848City permit record | COMBORECONNECT ELECTRIC;APT | Final | |
| 2015-04-07expired 2015-10-04 | T15BU00378City permit record | Pool / spaPOOL DEMO | Expired | |
| 2013-12-17expired 2014-06-18 | T13CM07631City permit record | COMBOELECTRIC & GAS RECONNECT | Closed | |
| 2012-07-16finaled | T12CM04269City permit record | COMBOBROKEN SEWER | Final | |
| 2012-07-16expired 2012-09-14 | T12EX00386City permit record | EXCAV4LF ASPHALT CUT FOR SEWER LINE REPAIR | Closed | |
| 2009-02-23finaled | T09PL00316City permit record | PLUMBGAS LINE:REPLACE APT. | Final | |
| 2009-02-10finaled | T09EL00246City permit record | ELECTRepair wire not up to code | Final | |
| 2009-02-10finaled | T09PL00238City permit record | PLUMBWATER HEATER (APA) | Final | |
| 2000-09-29finaled | T00PL01800City permit record | PLUMBGAS LINE:REPAIR UNIT #B | Final | |
| 1998-11-23finaled | T98PL02304City permit record | PLUMBGAS LINE:REPLACEMENT | Final | |
| 1997-11-12finaled | T97EL01893City permit record | ELECTRECONNECT:ELECTRIC:APT | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (17)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2025-11-25 | CE-VIO1125-05154Code enforcement case | Code enforcement case | Closed - unfounded |
| 2025-05-20 | CE-VIO0525-02176Code enforcement case | Code enforcement case | Closed - resolved |
| 2023-08-08 | CE-VIO0823-04992Code enforcement case | Fire | Closed - unfounded |
| 2023-04-20 | CE-VIO0423-03060Code enforcement case | Code enforcement case | Closed - unfounded |
| 2021-10-15 | T21DV07176Code enforcement case | Refuse | Noverify |
| 2020-06-03 | T20DV03872Code enforcement case | Fire | Complian |
| 2020-02-20 | T20DV01215Code enforcement case | Vegetation | Referred |
| 2018-10-18 | T18DV06796Code enforcement case | Code enforcement case | Complian |
Show 9 older records
| Date | Record | What | Status |
|---|---|---|---|
| 2018-05-04 | T18DV02552Code enforcement case | Refuse | Complian |
| 2016-11-14 | T16DV07757Code enforcement case | Code enforcement case | Complian |
| 2015-03-05 | T15DV01649Code enforcement case | Code enforcement case | Noverify |
| 2014-09-16 | T14DV07447Code enforcement case | Refuse | Complian |
| 2011-04-19 | T11DV02723Code enforcement case | Code enforcement case | Noverify |
| 2009-02-09 | T09DV00624Code enforcement case | Electrical | Complian |
| 2006-01-30finaled | T06FR00101Code enforcement case | Fire | Complete |
| 2006-01-30finaled | T06FR00102Code enforcement case | Fire | Complete |
| 2006-01-30finaled | T06FR00103Code enforcement case | Fire | Complete |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 12212184A — 29 permits on file from 1997 to 2025 (9 commercial building, 9 combo, 4 plumb, 2 addition / alteration) and 17 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.