Electrical permit history — 2221 N Rosemont Bl

2221 N Rosemont Bl, Tucson — built 1963, with 80 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

2221 N Rosemont Bl

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1963 — 1960s commercial stock · 1 open code case · 80 permits on record; no permitted panel/service or HVAC work among them

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 temporary certificate-of-occupancy (tco) permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Nothing permitted on the service or distribution shows in the record we read, which for a building of this era leaves the original switchgear generation in play. Obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown — worth establishing what is actually installed before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 temporary certificate-of-occupancy (tco) permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. The assessor records cooling as WARMED AND COOLED AIR and heating as Forced Air. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyFinaled permit foundLast permitted 2019 (7 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T19FC00754 — PANEL UPGRADES 2- REMOVED 2 4020 CONTROL PANELS & REPLACED WITH (2) 4100ES PANELS
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Composition Shingle. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth looking at

    There is an open code enforcement case on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    An ADU or casita was permitted in 2026, which means load has already been added to this property. Whether there is headroom left for anything more depends on how that was fed — a subpanel off the existing service, or its own.

  • Routine

    A trade permit was pulled in 2014. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 130,411 sq ft (county building-footprint layer, 4 structures)
Usable for solar, planning estimate
≈ 91,300 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 1,000 kW — roughly 2,500 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 1,650,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$132,000–$215,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “El Con Mall - Reid Park Area”, is about 1.9 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
12109290B
Year constructed
1963 (assessor record)
Permitting authority
Tucson
Zoning
O-3
Property type
Nursing/ Orphanage/ Rehab For Profit
Building area
8,380 sq ft
Cooling
WARMED AND COOLED AIR
Heating
Forced Air

The building area, cooling and heating above come from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 80 building permits for this parcel dated between 1998 and 2026. By category the work is state licensed facility operational fire (13), addition / alteration (11), trade permit (11) and general operational fire (10). 69 of them carry a final inspection; the other 11 were issued, expired or are still open, which is not the same as work completed. There are 4 code-enforcement cases recorded against the parcel, 1 of which is open. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 12109290B. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All commercial property · Commercial property in 85712 · Commercial & industrial reports · Homes in 85712 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on N ROSEMONT BL hold 326 City permits on record, 85 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (84 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026TS-PRM-0426-00151Permanent Sign PermitApproved
2026CE-VIO0726-02989Code enforcement caseActive
2026TC-CFO-0626-00110Temporary Certificate-of-Occupancy (TCO)Inspections Complete
2026TC-COM-1225-02255Commercial Addition/Alteration PermitInspections Complete
2026TC-COM-0226-00181Commercial Addition/Alteration PermitComplete
2026TF-FOP-0126-00072State Licensed Facility Operational Fire PermitComplete
2026recordRight-of-Way (ROW) Permit - UtilityComplete
2025TF-FOP-1025-01351General Operational Fire PermitComplete
2025TF-FOP-1025-01350General Operational Fire PermitComplete
2025TF-FOP-1025-01348State Licensed Facility Operational Fire PermitComplete
2025recordROW Permit - Residential Temporary UseNeeds Resubmittal
2024TF-FOP-0824-00990General Operational Fire PermitComplete
2024TF-FOP-0824-00991General Operational Fire PermitComplete
2024TF-FOP-0824-00988State Licensed Facility Operational Fire PermitComplete
2024recordROW Permit - Residential Temporary UseNeeds Resubmittal
2024TF-FOP-0823-01449State Licensed Facility Operational Fire PermitComplete
2024TF-FOP-0823-01451General Operational Fire PermitComplete
2024TF-FOP-0823-01452General Operational Fire PermitComplete
2023TF-FOP-1122-00135General Operational Fire PermitComplete
2023TF-FOP-1122-00134General Operational Fire PermitComplete
2022CE-VIO1222-00846FireClosed - Resolved
2022T22FO00756State Licensed Facility Operational Fire PermitComplete
2022T22SA00248Zoning ComplianceComplete
2022T22FO00006State Licensed Facility Operational Fire PermitComplete
2021T21FO00611State Licensed Facility Operational Fire PermitComplete
2021T21FO00612General Operational Fire PermitComplete
2021T21DV04529OBSTR DEAD TREES AND SHRUBSNOVERIFY
2021T21SA00077Zoning ComplianceComplete
2021T21FO00089State Licensed Facility Operational Fire PermitComplete
2020T20SA00365Zoning ComplianceComplete
2020T20FO00652State Licensed Facility Operational Fire PermitComplete
2020T20SA00088Zoning ComplianceComplete
2019T19FO00908General Operational Fire PermitComplete
2019T19FO00900State Licensed Facility Operational Fire PermitComplete
2019T19FC00754Fire Alarm System PermitComplete
2019T19FO00716State Licensed Facility Operational Fire PermitComplete
2018T18FO00800State Licensed Facility Operational Fire PermitComplete
2017T17OT00756Permanent Sign PermitComplete
2017T17FO00601State Licensed Facility Operational Fire PermitComplete
2016T16FC00156Fire Automatic Extinguishing System PermitComplete
2016T16FC00101Fire Alarm System PermitComplete
2016T16BU01144Fire Automatic Extinguishing System PermitComplete
2016T16CM05036Commercial Addition/Alteration PermitComplete
2016T16CM05189Commercial Addition/Alteration PermitComplete
2016T16BU00439Commercial Trade PermitIssued
2014T14BU00334Commercial Trade PermitComplete
2013T13BU01392Fire Automatic Extinguishing System PermitComplete
2013T13BU01324Fire Automatic Extinguishing System PermitComplete
2013T13CM04719Commercial New Building PermitComplete
2013DP12-0176Development PackageComplete
2013T13BU00869Commercial DemolitionComplete
2013T13CM04380Commercial Trade PermitComplete
2013T13BU00081Fire Automatic Extinguishing System PermitComplete
2013T12CM08235Commercial Addition/Alteration PermitComplete
2012T12BU01096Fire Automatic Extinguishing System PermitComplete
2011T11BU00340Fire Automatic Extinguishing System PermitComplete
2009T09DV04008CAR THROUGH RESIDENTIAL BUILDICOMPLIAN
2007T07OT00419Permanent Sign PermitComplete
2007T07BU00410Fire Automatic Extinguishing System PermitComplete
2005T05CM04960Residential Addition/Alteration PermitComplete
2003T03CM05361Commercial Addition/Alteration PermitCanceled
2003T03CM02967Commercial Addition/Alteration PermitComplete
2003T03CM03012Residential Addition/Alteration PermitWithdrawn
2003T03CM01468Commercial Addition/Alteration PermitComplete
2002T02OT01521Permanent Sign PermitComplete
2002T02OT00960Permanent Sign PermitComplete
2002T02OT00861Permanent Sign PermitComplete
2002T02BU01334Commercial Trade PermitComplete
2002T02OT00602Permanent Sign PermitComplete
2002T02BU00844Fire Automatic Extinguishing System PermitComplete
2002T02OT00455Permanent Sign PermitComplete
2001T01CM05651Commercial New Building PermitComplete
2001T01CM04239Commercial Addition/Alteration PermitCanceled
2001T01EL02574Residential Trade PermitComplete
2001T01CM05097Commercial Trade PermitCanceled
2001T01BU02209Commercial Trade PermitComplete
2001T01EL01359Commercial Trade PermitWithdrawn
2001T01CM02615Commercial Trade PermitCanceled
2001T01BU01295Fire Automatic Extinguishing System PermitComplete
2001T01PL00092Residential Trade PermitComplete
2000T00BU02348GradingComplete
2000T00CM00852Commercial New Building PermitComplete
1999T99ME00091Commercial Trade PermitComplete
1998T98OT00004Development PackageWithdrawn

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 12109290B — 80 City permits on file from 1998 to 2026 and 4 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area, cooling, heating, roof, walls on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.