Electrical permit history — 1675 N Wilmot Rd
1675 N Wilmot Rd, Tucson — built 1988, with 24 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
1675 N Wilmot Rd
Built 1988 — 1980s commercial stock · last permitted panel/service work 2021 (permitted, completion not confirmed)
Permanent link: Electrical permit history for 1675 N Wilmot Rd (aztucsonelectricalsolutions.com/property/12108094e/1675-n-wilmot-rd-tucson-az-85712) · Public records last checked 2026-08-16
- Parcel
- 12108094E
- Built
- 1988 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-2
- Assessor use
- Convenience Store With Fuel Dispensing
- Parcel size
- 0.73 acres
- Building area
- 2,147 sq ft (assessor record)
- Sewer
- Connection on file (1972, 1991) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- A 2021 permit was issued; completion is not confirmed in the available record; the permit description states “Upgrade existing Electrical Service to 800A, 3PH, 120/208V/ Revision 3 TEP changes, Delta 3 revise service rating from 800 amps to 600 amps 1-8-2024” — an increase in capacity as described, not a confirmed installed rating.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionPermitted — completion not confirmedA 2021 permit specifies this work (the permit description states “Upgrade existing Electrical Service to 800A, 3PH, 120/208V/ Revision 3 TEP changes, Delta 3 revise service rating from 800 amps to 600 amps 1-8-2024”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Inspections. City inspection record: COT - LCEL - Electrical Final approved 2025-06-17. T21CM02784 — Upgrade existing Electrical Service to 800A, 3PH, 120/208V/ Revision 3 TEP changes, Delta 3 revise service rating from 800 amps to 600 amps 1-8-2024
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyPermitted — completion not confirmedA 2022 permit specifies this work (the permit description states “Flammable & Combustible Liquid - INSTALL (2) 20,000 GAL UNDERGROUND FUEL TANKS, (2) DISPENSER SUMPS AND DOUBLEWALL PIPING.; Other Construction Permit; Additional Inspections: 3”), but the available record does not show a final inspection. The permit expired without a confirmed final status. Official status: Expired. T22FC00026 — Flammable & Combustible Liquid - INSTALL (2) 20,000 GAL UNDERGROUND FUEL TANKS, (2) DISPENSER SUMPS AND DOUBLEWALL PIPING.; Other Construction Permit; Additional Inspections: 3
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check
Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
Most recent permit on record for this parcel: 2025-02-12 (TC-COM-0225-00303) — Billboard sign No. COT 123 - Repair.
Permit history (24)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2025-02-12finaled | TC-COM-0225-00303City permit record | Commercial BuildingBillboard sign No. COT 123 - Repair | Complete | |
| 2022-02-18finaled | T22CM01247City permit record | Commercial BuildingFuel station underground fuel lines and tanks are being replaced. Disconnect electric to (2) dispens | Complete | |
| 2022-01-12expired 2022-10-21 | T22FC00025City permit record | Addition / alterationFlammable & Combustible Liquid - REMOVE (3) 10,000 GAL UNDERGROUND FUEL STORAGE TANKS.; Other Construction Permit; Additional Inspections: 4 | Expired | |
| 2022-01-12expired 2022-10-21 | T22FC00026City permit record | Addition / alterationFlammable & Combustible Liquid - INSTALL (2) 20,000 GAL UNDERGROUND FUEL TANKS, (2) DISPENSER SUMPS AND DOUBLEWALL PIPING.; Other Construction Permit; Additional Inspections: 3 | Expired | |
| 2021-03-30expired 2025-12-15 | T21CM02784City permit record | Commercial BuildingUpgrade existing Electrical Service to 800A, 3PH, 120/208V/ Revision 3 TEP changes, Delta 3 revise service rating from 800 amps to 600 amps 1-8-2024 | Inspections | |
| 2018-01-29finaled | T18FO00128City permit record | FIREOPERSTORE#2907 | Final | |
| 2017-11-15expired 2018-05-14 | T17OT01194City permit record | Fence / wall1-ILLUM WALL SIGN | Expired | |
| 2017-10-25finaled | T17OT01102City permit record | Fence / wall5-ILLUM SIGNS (4 WALL + 1 DF) | Final |
Show 16 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2017-03-08finaled | T17RW01076City permit record | ROWAERIAL FIBER OPTIC WORK. | Final | |
| 2017-01-03finaled | T17RW00057City permit record | ROWEXISTING PAVEMENT SAMPLING TO A MAXIMUN OF ONE FOOT 4" DIAMETER, 18 LOCATIONS TOTAL ADDRESSES ON APPLICATION- WILMOT- FROM PIMA STREET TO 800' SOUTH OF STELLA ROAD. CAPITAL PROJECT # TUCSON PAVEMENT RECONSTRUCTION FY 18 PACKAGE 2 | Final | |
| 2016-07-15expired 2017-01-31 | T16CM05513City permit record | COMBOREPL OUTDOOR LIGHT FIXTURES | Expired | |
| 2015-04-04finaled | T15TC00859City permit record | BARRICADONE MILE SCHEDULED MAINTENANCE WORK. | Final | |
| 2009-11-24 | T09CM03084City permit record | COMBOSITE IMPROVEMENTS T09DV05959 | Withdrwn | |
| 2009-09-17finaled | T09BU01392City permit record | TANKSREPLACE: GAS DISPENSERS LIKE FOR LIKE | Final | |
| 2009-07-20 | T09AN00414City permit record | ADDRNEW | Issued | |
| 2009-07-20finaled | T09CM01922City permit record | COMBOTI:CIRCLE K | Final | |
| 2009-04-21expired 2009-06-20 | T09EX00238City permit record | EXCAVEXCAVATION OF 6' WITH REMOVAL OF SIDEWALK TO REPLACE WATERLINE | Closed | |
| 2009-04-21finaled | T09PL00703City permit record | PLUMBREPLACE:WATER LINE BY WATER METER | Final | |
| 2004-08-02expired 2010-05-22 | T04OT01534City permit record | SIGNSIGN:7542 | Closed | |
| 2004-03-12expired 2004-09-08 | T04ME00122City permit record | MECHREPLACE:HEAT PUMPS (APA) | Closed | |
| 2000-09-15finaled | T00EL02210City permit record | ELECTSIGN:ELECTRIC:1465 | Final | |
| 2000-08-02expired 2001-01-29 | T00ME00864City permit record | MECHREPLACEMENT:3 TON A/C | Closed | |
| 2000-06-01expired 2000-11-29 | T00EL01370City permit record | ELECTSERVICE:ELECTRIC | Closed | |
| 1997-11-12finaled | T97CM03655City permit record | COMBOTI:LIGHT POLE INSTALL & BASE | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (5)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2022-06-17 | T22DV03482Code enforcement case | Code enforcement case | Noverify |
| 2018-12-28 | T18DV08255Code enforcement case | Code enforcement case | Complian |
| 2013-07-01 | T13DV04564Code enforcement case | Graffiti | Noverify |
| 2011-01-27 | T11FR00251Code enforcement case | Code enforcement case | Field |
| 2009-10-16 | T09DV05959Code enforcement case | Code enforcement case | Complian |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Send: the permanent link and the summary above, once. Watch: one email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list either way.
How this report was built
This is a reading of public records for parcel 12108094E — 24 permits on file from 1997 to 2025 (4 combo, 3 commercial building, 2 addition / alteration, 2 fence / wall) and 5 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.