Electrical permit history — 6160 E Bellevue St
6160 E Bellevue St, Tucson — built 1975, with 12 permits on record. Review electrical, HVAC and remodel history with links to official records.
Multifamily property
6160 E Bellevue St
Built 1975 — 1970s multifamily stock · last permitted panel/service work 2013 (finaled) · HVAC 1998 (finaled)
Permanent link: Electrical permit history for 6160 E Bellevue St (aztucsonelectricalsolutions.com/property/12108031e/6160-e-bellevue-st-tucson-az-85712) · Public records last checked 2026-08-16
- Parcel
- 12108031E
- Built
- 1975 (county record)
- Jurisdiction
- Tucson
- Zoning
- R-3
- Assessor use
- Apartments 100+ Units 2 Story
- Parcel size
- 2.95 acres
- Building area
- 78,600 sq ft (assessor record)
- Sewer
- Connection on file (1974) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- City records show the 2013 permit was finalized; the permit description states “UPGRADE 100 AMP” — an increase in capacity as described, not a confirmed installed rating.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionCurrentLast permitted 2013 (13 years ago). City inspection record: ELECTRIC - FINAL approved 2013-01-31. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T13CM00465 — UPGRADE 100 AMP
- Heating, cooling & mechanicalLikely dueLast permitted 1998 (28 years ago). Contractor of record: MC COOK BOILER AND PUMP CO ,. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Equipment from before about 2010 generally runs R-22, which has not been produced since 2020 — repairs mean reclaimed refrigerant at a price that often exceeds replacing the unit. T98ME00351 — BOILER:115 GAL ASME STORAGE TANK
- Fire alarm & life safetyCurrentLast permitted 2021 (5 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T21FC00702 — Replace the existing FACP in Building 1.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
There is an electrical reconnect permit from 2016. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.
Recorded sales (1)
| Date | Price | Type |
|---|---|---|
| 2003-12-18 | $3,175,000 | Special Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2021-09-15 (T21FC00702) — Replace the existing FACP in Building 1..
Permit history (12)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2021-09-15finaled | T21FC00702City permit record | FIRECONSReplace the existing FACP in Building 1. | Final | |
| 2020-02-03finaled | T20RW00620City permit record | ROWINSTALLATION OF SMALL CELL EQUIPMENT MOUNTED ON EXISTING COX STRAND ON THE WEST SIDE OF 6160 E BELLEVUE ST. SITE NUMBER: PH79ASJ09_B | Final | |
| 2019-08-27finaled | T19RW04680City permit record | ROWTEP TO REMOVE EQUIPMENT FROM POLE | Final | |
| 2019-06-07finaled | T19FC00435City permit record | FIRECONSReplace the fire panel and 3 smoke detectors in building A | Final | |
| 2016-03-01finaled | T16CM01573City permit record | Electrical reconnectELECTRICAL RECONNECT | Final | |
| 2015-05-15expired 2016-02-14 | T15OT00664City permit record | SIGN90 DAY BANNER 05/15/2015-08/13/2015 | Expired | |
| 2013-05-30finaled | T13CM03290City permit record | COMBOREPLACE BREAKER - APT | Final | |
| 2013-01-25finaled | T13CM00465City permit record | COMBOUPGRADE 100 AMP | Final |
Show 4 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2012-08-14expired 2013-02-16 | T12CM05017City permit record | COMBOREPLACE ELECTRICAL BREAKER - APT. | Expired | |
| 2002-12-11finaled | T02OT01941City permit record | SIGNSIGN:4854 | Final | |
| 1998-08-27finaled | T98ME00658City permit record | MECHPRESSURE VESSEL CERTIFICATE:TUC-22016,22017 | Final | |
| 1998-05-15finaled | T98ME00351City permit record | MECHBOILER:115 GAL ASME STORAGE TANK | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (17)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2024-07-09 | CE-VIO0724-02656Code enforcement case | Fire | Closed - resolved |
| 2022-04-18 | T22DV02498Code enforcement case | Code enforcement case | Noverify |
| 2021-12-14 | T21DV08887Code enforcement case | Code enforcement case | Noverify |
| 2016-07-11 | T16DV04191Code enforcement case | Code enforcement case | Complian |
| 2015-05-02 | T15DV03356Code enforcement case | Work without permit | Complian |
| 2014-10-24 | T14DV08951Code enforcement case | Code enforcement case | Noverify |
| 2013-11-01 | T13DV08145Code enforcement case | Code enforcement case | Complian |
| 2011-02-11 | T11DV00874Code enforcement case | Electrical | Void |
Show 9 older records
| Date | Record | What | Status |
|---|---|---|---|
| 2011-02-01 | T11DV00681Code enforcement case | Code enforcement case | Noverify |
| 2010-06-25 | T10DV04161Code enforcement case | Vegetation | Noverify |
| 2009-04-01 | T09DV01615Code enforcement case | Code enforcement case | Noverify |
| 2006-02-22finaled | T06FR00214Code enforcement case | Code enforcement case | Complete |
| 2002-01-02 | T02VL00005Code enforcement case | Code enforcement case | Complian |
| 2001-08-22 | T01VL02420Code enforcement case | Code enforcement case | Closed |
| 2001-08-09 | T01VL02272Code enforcement case | Electrical | Complian |
| 1999-06-02 | T99VL01508Code enforcement case | Sign | Complian |
| 1999-01-06 | T99VL00018Code enforcement case | Sign | Complian |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, once. No list, no follow-up unless you ask for it.
How this report was built
This is a reading of public records for parcel 12108031E — 12 permits on file from 1998 to 2021 (3 combo, 2 firecons, 2 row, 2 sign) and 17 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.