Electrical permit history — 5504 E Pima St

5504 E Pima St, Tucson — built 1977, with 1 permit on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

5504 E Pima St

Built 1977 — 1970s commercial stock · 1 permit on record; no permitted panel/service or HVAC work among them

Parcel
12106225A
Built
1977 (county record)
Jurisdiction
Tucson
Zoning
C-1
Assessor use
Nursing/ Orphanage/ Rehab For Profit
Parcel size
0.68 acres
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 5504 E Pima St, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Flood and drainage — two different maps

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map. Pima County’s Regional Flood Control District and the City of Tucson regulate against their own, and that is the one a permit here is judged against.

FEMA flood hazard (federal)
FEMA flood hazard (federal) for 5504 E Pima St, Tucson area, Arizona

FEMA National Flood Hazard Layer — zones and base-flood-elevation contours. Federal insurance mapping. Open this property on FEMA’s official flood map ↗

Local regulatory floodplain (county and City)
Local regulatory floodplain (county and City) for 5504 E Pima St, Tucson area, Arizona

Pima County RFCD local floodplains, floodways, sheet-flooding and erosion hazard areas, with the City of Tucson’s own mapped flood hazards. This is the map local floodplain regulation uses.

Parcel outlined in yellow. Both maps are drawn live from the agencies’ own map services at the same extent, so you can compare them directly. They are context for planning, not a floodplain determination — for that, ask the floodplain administrator for the jurisdiction shown below.

  • FEMA: the federal flood layer did not answer when this page was built. That is a lookup failure, not a statement about the property.
  • Pima County RFCD: No Pima County regulated local floodplain, floodway, sheet-flooding area or erosion hazard area is mapped at this location. That is the county's map, not a statement about drainage on the site.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2015-04-04 (T15TC00860) — ONE MILE SCHEDULED MAINTENANCE WORK..

Permit history (1)

Permit history for this parcel — 1 of 1 records
DateRecordWhatStatusValue
2015-04-04finaledT15TC00860City permit recordBARRICADONE MILE SCHEDULED MAINTENANCE WORK.Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All commercial property · Commercial property in 85712 · Commercial & industrial reports · Homes in 85712 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 12106225A — 1 permit on file from 2015 to 2015 (1 barricad) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-18; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.