Electrical permit history — 6268 E Grant Rd

6268 E Grant Rd, Tucson — built 1999, with 27 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

6268 E Grant Rd

Build year not published — permits on file from 1999 · 27 permits on record; no permitted panel/service or HVAC work among them

Parcel
12101103J
Built
1999 (earliest permit on file)
Jurisdiction
Tucson
Zoning
C-1
Assessor use
Medical Dental Service
Parcel size
0.88 acres
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 6268 E Grant Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2000. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Routine

    Office and medical tenant improvements are usually limited by available panel spaces and branch circuit capacity, not by the service itself.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2007-06-29$10,140,000Warranty Deed
1999-06-30$1,850,000Special Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-07-19 (TZ-CMP-0726-00142) — Zoning Compliance Letter Wilmot Plaza.

Permit history (27)

Permit history for this parcel — 8 of 27 records
DateRecordWhatStatusValue
2026-07-19TZ-CMP-0726-00142City permit recordZoning Verification LetterZoning Compliance Letter Wilmot PlazaFees paid
2026-06-17finaledTF-FOP-0626-00867City permit recordFire OperationalAgility/Sol Physical TherapyComplete
2025-06-27finaledTF-FOP-0625-00918City permit recordFire OperationalOutpatient physical therapy clinicComplete
2024-05-30finaledTF-FOP-0524-00648City permit recordFire OperationalSLF B Occupancy Sol PT.Complete
2021-06-22finaledT21OT00468City permit recordFence / wall1= non illum wall signFinal
2019-05-17finaledT19CM03511City permit recordCOMBOREPL 3 TON 3PHGAS PACK LIKE FOR LIKEFinal
2018-09-17finaledT18CM07361City permit recordCOMBOREPLACE HEAT PUMPFinal
2017-01-10expired 2017-07-18T17OT00035City permit recordFence / wall1- NON ILLUM WALL SIGNExpired
Show 19 older records
Permit history for this parcel — remaining 19 records
DateRecordWhatStatusValue
2016-08-23expired 2017-02-19T16OT01030City permit recordFence / wall1- NON ILLUM WALL SIGNExpired
2016-08-19finaledT16CM06464City permit recordCOMBOREPL 4TON PACKAGED HEAT PUMPFinal
2016-07-19finaledT16CM05592City permit recordCOMBOMEDICALC of o
2016-06-09finaledT16CM04426City permit recordCOMBOOFFICE TIFinal
2016-06-01finaledT16CM04094City permit recordCOMBOTI: PHYSICAL THERAPY OFFICEC of o
2014-01-17expired 2014-11-01T14CM00337City permit recordCOMBOFACADE REMODELExpired
2013-07-02expired 2014-07-08T13CM04030City permit recordCOMBOFACADE REMODELClosed
2006-11-01T06AN01121City permit recordADDRNEWIssued
2006-11-01finaledT06CM05699City permit recordCOMBOTI: MEDICAL OFFICE TCO FOR INSTALLATION OF MEDICAL EQUIPMENTC of o
2002-07-30finaledT02OT01155City permit recordSIGNSIGN:# 4279Final
2002-07-30finaledT02OT01157City permit recordSIGNSIGN:# 4278Final
2001-01-30finaledT01CM00477City permit recordCOMBOEXPANSION:MEDICAL OFFICE- 2500 sq ftC of o
2000-10-09expired 2001-04-29T00BU03010City permit recordAddition / alterationADDITION:CARPORTS TD# 14-34-51Expired
2000-08-02T00CM03812City permit recordCOMBOTI:OFFICEWithdrwn
2000-07-21finaledT00EL01785City permit recordELECTINSTALL: X RAY UNITFinal
2000-02-22finaledT00CM00825City permit recordCOMBOTI:OFFICEFinal
2000-01-10finaledT00EL00073City permit recordELECTRECONNECT:ELECTRIC CLASSROOMFinal
1999-12-29P99AN03802City permit recordADDRNEWIssued
1999-12-29finaledT99EL03326City permit recordELECTRECONNECT:ELECTRIC:RETAILFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 12101103J — 27 permits on file from 1999 to 2026 (12 combo, 3 fire operational, 3 fence / wall, 3 elect) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.