Electrical permit history — 4823 S 6th Av

4823 S 6th Av, Tucson — built 1970, with 96 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

4823 S 6th Av

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1970 — 1970s commercial stock · HVAC 2005 (finaled)

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 special events fire permit - organizer permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Nothing permitted on the service or distribution shows in the record we read, which for a building of this era leaves the original switchgear generation in play. Obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown — worth establishing what is actually installed before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalLikely dueLast permitted 2005 (21 years ago). Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Equipment from before about 2010 generally runs R-22, which has not been produced since 2020 — repairs mean reclaimed refrigerant at a price that often exceeds replacing the unit. T05ME00412 — REPLACE: HVAC RETROIT
  • Fire alarm & life safetyFinaled permit foundLast permitted this year (2026). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-1225-01048 — Install new Fire Alarm System to monitor the Fire Sprinkler system at the city of Tucson Rodeo Museum Site.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Routine

    A trade permit was pulled in 2015. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 106,550 sq ft (county building-footprint layer, 16 structures; 1 neighbouring structure crossing the lot line excluded)
Usable for solar, planning estimate
≈ 74,600 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 820 kW — roughly 2,050 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 1,350,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$108,000–$176,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Aviation Pkwy and Kino Pkwy”, is about 3.3 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
12009308A
Year constructed
1970 (assessor record)
Permitting authority
Tucson
Zoning
C-2
Property type
Municipal Commercial Property
Building area
57,848 sq ft

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 96 building permits for this parcel dated between 2001 and 2026. By category the work is special events fire permit - organizer (30), special events fire permit - vendor (25), addition / alteration (10) and trade permit (10). 88 of them carry a final inspection; the other 8 were issued, expired or are still open, which is not the same as work completed. There are 4 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 12009308A. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All institutional and public property · Commercial property in 85714 · Commercial & industrial reports · Homes in 85714 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on S 6TH AV hold 1,051 City permits on record, 200 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (100 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026TC-DMO-0926-00158Commercial Demolition PermitIssued
2026TC-COM-1026-01688Commercial Addition/Alteration PermitNeeds Resubmittal
2026TC-DMO-0826-00144Commercial Demolition PermitOn Hold
2026TF-FOP-0426-00435Special Events Fire Permit - OrganizerComplete
2026TF-FOP-0126-00073Special Events Fire Permit - VendorComplete
2026TF-FOP-0226-00269Special Events Fire Permit - OrganizerComplete
2026recordROW Permit - Special EventsComplete
2026TF-FOP-0126-00084Special Events Fire Permit - VendorComplete
2026TF-FCP-1225-01048Fire Alarm System PermitComplete
2025recordRight-of-Way (ROW) Permit - UtilityIssued
2025recordROW Permit - City CIP/JOCComplete
2025TF-FOP-0425-00488Special Events Fire Permit - OrganizerComplete
2025recordROW Permit - Special EventsComplete
2025TF-FOP-1024-01147Special Events Fire Permit - OrganizerComplete
2025TF-FOP-0125-00063Special Events Fire Permit - VendorComplete
2025TF-FOP-0125-00022Special Events Fire Permit - VendorComplete
2024TC-COM-1124-02242Commercial Addition/Alteration PermitExpired
2024TF-FOP-0924-01061Special Events Fire Permit - VendorComplete
2024TF-FOP-0724-00763Special Events Fire Permit - OrganizerComplete
2024TF-FOP-0824-00920Special Events Fire Permit - OrganizerComplete
2024TF-FOP-0324-00342Special Events Fire Permit - VendorComplete
2024TF-FOP-0324-00331Special Events Fire Permit - OrganizerComplete
2024recordROW Permit - Special EventsComplete
2024TF-FOP-0224-00180Special Events Fire Permit - VendorComplete
2024TF-FOP-0124-00047Special Events Fire Permit - VendorComplete
2024TF-FOP-0124-00082Special Events Fire Permit - OrganizerComplete
2023TF-FOP-0823-01377Special Events Fire Permit - OrganizerComplete
2023recordROW Permit - Special EventsComplete
2023TF-FOP-0223-00458Special Events Fire Permit - OrganizerComplete
2022recordROW Permit - Special EventsComplete
2022TF-FOP-1122-00020Special Events Fire Permit - OrganizerComplete
2022TF-FOP-1122-00046Special Events Fire Permit - OrganizerComplete
2022T22FO00830Special Events Fire Permit - OrganizerComplete
2022T22FO00713Special Events Fire Permit - OrganizerComplete
2022T22FO00338Special Events Fire Permit - VendorComplete
2022T22FC00166Fire Alarm System PermitExpired
2022T22FO00143Special Events Fire Permit - VendorComplete
2021T21FO00879Special Events Fire Permit - OrganizerComplete
2021T21CM08812Commercial Addition/Alteration PermitComplete
2021T21FO00740Special Events Fire Permit - VendorComplete
2021T21FO00721Special Events Fire Permit - OrganizerComplete
2021T21CM08343Commercial Trade PermitWithdrawn
2021T21FO00453Special Events Fire Permit - OrganizerComplete
2021T21FO00281Special Events Fire Permit - VendorComplete
2020T20DV07465CLEAN CITIES INITIATIVE PGRMNOVERIFY
2020T20FO00110Special Events Fire Permit - VendorComplete
2020T20FO00109Special Events Fire Permit - VendorComplete
2020T20FO00111Special Events Fire Permit - OrganizerComplete
2020T20FO00005Special Events Fire Permit - OrganizerComplete
2020T18FO00969Special Events Fire Permit - VendorComplete
2019T19FO01019Special Events Fire Permit - OrganizerComplete
2019T19FO00967Special Events Fire Permit - VendorComplete
2019T19FO00108Special Events Fire Permit - VendorComplete
2019T19FO00074Special Events Fire Permit - VendorComplete
2019T18FO01063Special Events Fire Permit - OrganizerComplete
2018T18FO00896Special Events Fire Permit - OrganizerComplete
2018T18FO00719Special Events Fire Permit - OrganizerComplete
2018T18FO00410Special Events Fire Permit - OrganizerComplete
2018T18FO00174Special Events Fire Permit - OrganizerComplete
2018T18FO00158Special Events Fire Permit - VendorComplete
2018T18FO00153Special Events Fire Permit - VendorComplete
2018T18FO00106Special Events Fire Permit - OrganizerComplete
2018T18FO00013Special Events Fire Permit - OrganizerComplete
2018T18DV00017ILLEGAL DUMPINGCOMPLIAN
2017T17FO00426Special Events Fire Permit - OrganizerComplete
2017T17FO00947Special Events Fire Permit - OrganizerComplete
2017T17FO00864Special Events Fire Permit - VendorComplete
2017T17FO00231Special Events Fire Permit - OrganizerComplete
2017T17FO00089Special Events Fire Permit - VendorComplete
2017T17FO00051General Operational Fire PermitComplete
2017T17FO00032Special Events Fire Permit - VendorComplete
2016T16FO00074Special Events Fire Permit - VendorComplete
2016T16FO00047Special Events Fire Permit - VendorComplete
2016T16FO00033General Operational Fire PermitComplete
2016T16CM05688Commercial Addition/Alteration PermitComplete
2016DP16-0124Development PackageComplete
2016T16DV03008MULTI-AGENCY INSPECTION TEAMCOMPLIAN
2016T16DV03009MULTI-AGENCY INSPECTION TEAMCOMPLIAN
2015T15CM06000Commercial Trade PermitComplete
2013T13CM04790Commercial Trade PermitComplete
2013T13BU00673Commercial DemolitionComplete
2012T12BU01430Commercial Trade PermitComplete
2012T12BU00750Fire Automatic Extinguishing System PermitComplete
2012T12BU00752Fire Automatic Extinguishing System PermitComplete
2012T12BU00751Fire Automatic Extinguishing System PermitComplete
2011T11EL00422Commercial Trade PermitComplete
2009T07CM04780Commercial Addition/Alteration PermitComplete
2009T09OT00187Permanent Sign PermitComplete
2008T08CM03037Commercial Addition/Alteration PermitComplete
2008T08CM03259Commercial Addition/Alteration PermitComplete
2008T08EL00207Commercial Trade PermitComplete
2007T07CM02747Commercial Trade PermitComplete
2007T06CM05526Commercial Addition/Alteration PermitComplete
2007T06CM02118Commercial Addition/Alteration PermitComplete
2005T05ME00412Commercial Trade PermitComplete
2005T05BU00198Commercial DemolitionComplete
2003T03CM00913Commercial Trade PermitComplete
2002T02BU02973GradingWithdrawn
2002T02EL02273Commercial Trade PermitComplete
2001T00CM00711Commercial Addition/Alteration PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 12009308A — 96 City permits on file from 2001 to 2026 and 4 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-11-13.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.