Built 1980 — 1980s commercial stock · last permitted panel/service work 2006 (finaled)

Is it time to upgrade?

  • Electrical service & distributionFinaled permit foundLast permitted 2006 (20 years ago). Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T06EL01554 — NEW ELEC SERVICE R1 - Ste# change from 101 to 111
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2011 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    A finaled 2006 panel/service permit is on record for this parcel, which makes it unlikely the original 100–150 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Routine

    A trade permit was pulled in 2006. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 8,343 sq ft (county building-footprint layer; capped at the parcel’s land area — a mapped structure crosses the lot line)
Usable for solar, planning estimate
≈ 5,800 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 65 kW — roughly 160 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 110,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$9,000–$14,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Aviation Pkwy and Kino Pkwy”, is about 3.4 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
120080960
Year constructed
1980 (assessor record)
Permitting authority
Tucson
Zoning
C-2
Property type
Store Front Commercial Bldg
Building area
11,085 sq ft
Service on record
City records show the 2006 permit was finalized; the permit description states “NEW ELEC SERVICE R1 - Ste# change from 101 to 111”.

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permit with evidence of issuance is dated 2011. City records show the permit was finalized. The permit covers only the work described in that record.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permit with evidence of issuance is dated 2011. City records show the permit was finalized. The permit covers only the work described in that record.

What that reading rests on. The issuing offices hold 16 building permits for this parcel dated between 2005 and 2015. By category the work is addition / alteration (8), permanent sign (5), annual portable sign compliance and peddler permit. 12 of them carry a final inspection; the other 4 were issued, expired or are still open, which is not the same as work completed. There are 12 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 120080960. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All commercial property · Commercial property in 85714 · Commercial & industrial reports · Homes in 85714 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on S 12TH AV hold 665 City permits on record, 99 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (28 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2021T21DV02001RESIDENTIAL ZONINGCOMPLIAN
2015T15DV05801SIGN VIOLATIONCOMPLIAN
2015T15OT00563Annual Portable Sign ComplianceCanceled
2015T15DV02637SIGN VIOLATIONCOMPLIAN
2014T14DV10204CLEAN CITIES INITIATIVE PGRMCOMPLIAN
2014T14DV09592SIGN VIOLATIONCOMPLIAN
2014T14CM01388Commercial Addition/Alteration PermitWithdrawn
2014T14DV00451GRAFFITICOMPLIAN
2013T13OT01117Peddler PermitCanceled
2013T13DV01220GRAFFITICOMPLIAN
2013T13DV00170GRAFFITINOVERIFY
2012T12OT00311Permanent Sign PermitCanceled
2012T12DV01331SIGN VIOLATIONCOMPLIAN
2012T12DV01189SIGN VIOLATIONCOMPLIAN
2011T11CM00808Commercial Addition/Alteration PermitComplete
2010T10DV07863WEEDSCOMPLIAN
2009T09DV00729SIGN VIOLATIONCOMPLIAN
2007T07OT01929Permanent Sign PermitComplete
2006T06EL01554Commercial Trade PermitComplete
2006T06CM00768Commercial Addition/Alteration PermitComplete
2006T06CM00769Commercial Addition/Alteration PermitComplete
2006T05OT03127Permanent Sign PermitComplete
2006T05OT03128Permanent Sign PermitComplete
2005T05OT02731Commercial Addition/Alteration PermitComplete
2005T05CM05938Commercial Addition/Alteration PermitComplete
2005T05CM05939Commercial Addition/Alteration PermitComplete
2005T05OT01203Commercial Addition/Alteration PermitComplete
2005T05OT01989Permanent Sign PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 120080960 — 16 City permits on file from 2005 to 2015 and 12 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-08-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).